• Title/Summary/Keyword: medium voltage

Search Result 425, Processing Time 0.032 seconds

A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer (식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구)

  • Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

Comparison of Efficiency for Voltage Source and Current Source Based Converter in 5MW PMSG Wind Turbine Systems

  • Kang, Tahyun;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.357-358
    • /
    • 2015
  • This paper provides a comparison of power converter loss and thermal description for voltage source and current source type 5MW-class medium voltage topologies of wind turbines. Neutral-point clamped three-level converter is adopted for voltage source type topology while two-level converter is employed for current source type topology considering the popularity in the industry. In order to match the required voltage level of 4160V with the same switching device of IGCT as in voltage source converter, two active switches are connected in series for the case of current source converter. The loss analysis is confirmed through PLECS simulations. In addition, the loss factors due to di/dt and dv/dt snubber and ac input filter are presented. The comparison result shows that VSC-based wind turbine system has a higher efficiency than that of CSC under the rated operating conditions.

  • PDF

A Hybrid Modular Multilevel Converter Topology with an Improved Nearest Level Modulation Method

  • Wang, Jun;Han, Xu;Ma, Hao;Bai, Zhihong
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.96-105
    • /
    • 2017
  • In this paper, a hybrid modular multilevel converter (MMC) topology with an improved nearest level modulation method is proposed for medium-voltage high-power applications. The arm of the proposed topology contains N series connected half-bridge submodules (HBSMs), one full-bridge submodule (FBSM) and an inductor. By exploiting the FBSM, half-level voltages are obtained in the arm voltages. Therefore, an output voltage with a 2N+1 level number can be generated. Moreover, the total level number of the inserted submodules (SMs) is a constant. Thus, there is no pulse voltage across the arm inductors, and the SM capacitor voltage is rated. With the proposed voltage balancing method, the capacitor voltage of the HBSM is twice the voltage of the FBSM, and each IGBT of the FBSM has a relatively low switching frequency and an equalized conduction loss. The capacitor voltage balancing methods of the two kinds of SMs are implemented independently. As a result, the switching frequency of the HBSM is not increased compared to the conventional MMC. In addition, according to a theoretical calculation of the total harmonic distortion of the electromotive force (EMF), the voltage quality with the presented method can be significantly enhanced when the SM number is relatively small. Simulation and experimental results obtained with a MMC-based inverter verify the validity of the developed method.

Optimal Voltage Vector Selection Method for Torque Ripple Reduction in the Direct Torque Control of Five-phase Induction Motors

  • Kang, Seong-Yun;Shin, Hye Ung;Park, Sung-Min;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1203-1210
    • /
    • 2017
  • This paper presents an improved switching selection method for the direct torque control (DTC) of five-phase induction motors (IMs). The proposed method is conducted using optimal switching selection. A five-phase inverter has 32 voltage vectors which are divided into 30 nonzero voltage vectors and two zero voltage vectors. The magnitudes of the voltage vectors consist of large, medium, and small voltage vectors. In addition, these vectors are related to the torque response and torque ripple. When a large voltage vector is selected in a drive system, the torque response time decreases with an increased torque ripple. On the other hand, when a small voltage vector is selected, the torque response time and torque ripple increase. As a result, this paper proposes an optimal voltage vector selection method for improved DTC of a five-phase induction machine depending on the situation. Simulation and experimental results verify the effectiveness of the proposed control algorithm.

Droop Control for Parallel Inverers in Islanded Microgrid Considering Unbalanced Low-Voltage Line Impedances (마이크로그리드 독립 운전 모드시 저전압 불평형 선로 임피던스를 고려한 드룹 방식의 인버터 병렬 운전 제어 연구)

  • Lim, Kyung-Bae;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.387-396
    • /
    • 2013
  • This paper investigates the droop control of parallel inverters for an islanded mode of microgrid. Frequency and voltage droop control is one of power control and load demand sharing methods. However, although the active power is properly shared, the reactive power sharing is inaccurate with conventional method due to the unequal line impedances and the power coupling of active - reactive power. In order to solve this problem, an improved droop method with virtual inductor concept and a voltage and current controller properly designed have been considered and analyzed through the PSiM simulation. The performance of improved droop method is analyzed in not only low-voltage line but also medium voltage line.

The effects of SCOPF solution to Transient Stability on Voltage Limited Power System (전압안정도로 제약된 계통에서 최적조류계산해가 과도안정도에 미치는 영향)

  • Lee, Geun-Joon;Kim, Bal-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.245-247
    • /
    • 2001
  • This paper presents a series of simulation results of transient stability on SCOPF operated power system whose transmission capabilities are limited by voltage stability. Three steps of voltage security guidelines, 5[%], 7[%], 10[%] are introduced to increase power transfer from generation centers to load center and observed the effects of voltage guidelines to transient stability for three kinds of load level(peak, medium, off-peak). As a result, dynamic characteristics weren't affected by the voltage security limits in model system, but became worse for the off-peak level than peak case, and sustain oscillations are observed for the all load level. This gives us some intitutions for the development and applications of security limits to use SCOPF program in open electric market.

  • PDF

Multilevel Inverter to Reduce Common Mode Voltage in AC Motor Drives Using SPWM Technique

  • Renge, Mohan M.;Suryawanshi, Hiralal M.
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.21-27
    • /
    • 2011
  • In this paper, an approach to reduce common-mode voltage (CMV) at the output of multilevel inverters using a phase opposition disposed (POD) sinusoidal pulse width modulation (SPWM) technique is proposed. The SPWM technique does not require computations therefore, this technique is easy to implement on-line in digital controllers. A good tradeoff between the quality of the output voltage and the magnitude of the CMV is achieved in this paper. This paper realizes the implementation of a POD-SPWM technique to reduce CMV using a five-level diode clamped inverter for a three phase induction motor. Experimental and simulation results demonstrate the feasibility of the proposed technique.

New Fabrication Approach for Low Voltage Driving Electrophoretic Display

  • Park, Young-Mi;Kim, Do-Yun;Cho, Young-Tae;Lee, Yong-Eui;Kim, Chul-Hwan;Yoon, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.893-895
    • /
    • 2009
  • In this paper, we described the unique and novel method to prepare two kinds of electro-active particles, black and white particles with different polarity. The surface of the particles was characterized to be uniform and clean by adopting spray dryer as a tool for genesis of particles; neither surfactants nor high dielectric medium like water was employed during particle preparation step. The other purpose of this study is to investigate the factors that contribute high driving voltage of particlebased display like QR-LPD. We extracted parameters interaction between particle and electrode, and between oppositely charged particles. Here we reported an excellent behavior of particle-based display that showed low operating voltage, high contrast ratio as high as 8:1 without scarification of quick response time. By optimizing the particle size, charge per mass, selection of external additive sets, a lower driving voltage as low as 40V for the particles with $10{\mu}m$ volume average diameter was obtained.

  • PDF

Optimized PWM Switching Strategy for an Induction Motor Voltage Control

  • Lee, Hae-Hyung;Hwang, Seuk-Yung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.527-533
    • /
    • 1998
  • An optimized PWM switching strategy for an induction motor voltage control is developed and demonstrated. Space vector modulation in voltage source inverter offers improved DC-bus utilization and reduced commutation losses, and has been therefor recognizedas the perfered PWM method, especially in the case of digital implementation. Three-phase invertor voltage control by space vector modulation consists of switching between the two active and one zero voltage vector by using the proposed optimal PWM algorithm. The prefered switching sequence is defined as a function of the modulation index and period of a carrier wave. The sequence is selected by suing the inverter switching losses and the current ripple as the criteria. For low and medium power application, the experimental results indicate that good dynamic response and reduced harmonic distortion can be achieved by increasing switching frequency.

  • PDF

Prediction of temperature rise of Electric Switching Device Using CFD-CAD Integrated Analysis (CFD-CAD 통합해석을 이용한 전력기기 온도상승 예측)

  • Ahn, Heui-Sub;Lee, Jong-C.;Choi, Jong-Ung;Oh, Il-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.808-810
    • /
    • 2002
  • Higher current-rating and improved thermal performance are being sought for existing medium-voltage vacuum circuit breakers(VCB) in order to meet market needs which require to be compact and downsized. In this paper, thermal performance of medium voltage vacuum circuit breaker was investigated through experiments and numerical analysis. We changed several major parameters of current-rating and heat sink affecting on thermal behaviors in the breaker and observed the results. To predict the temperature distribution in complex three-dimensional (3-D) VCB components and gas, the commercial package was used to simulate conjugate heat transfer. Although some assumptions and simplifications were introduced to simulate the model, results from the computational model were in good agreement with actual temperature rise measurements obtained from experiments.

  • PDF