• Title/Summary/Keyword: medical images

Search Result 2,837, Processing Time 0.032 seconds

Comparison of brain wave values in emotional analysis using video (영상을 이용한 감정분석에서의 뇌파 수치 비교)

  • Jae-Hyun Jo;Sang-Sik Lee;Jee-Hun Jang;Jin-Hyoung Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.519-525
    • /
    • 2023
  • The human brain constantly emits electrical impulses, which is called brain waves, and brain waves can be defined as the electrical activity of the brain generated by the flow of ions generated by the biochemical interaction of brain cells. There is a study that emotion is one of the factors that can cause stress. Brain waves are the most used in the study of emotions. This paper is a study on whether emotions affect stress, and showed two images of fear and joy to four experimenters and divided them into three stages before, during, and after watching. As a measurement tool, brain waves at the positions of Fp1 and Fp2 were measured using the NeuroBrain System, a system that can automate brain wave measurement, analysis, brain wave reinforcement, and suppression training with remote control. After obtaining the brain wave data for each emotion, the average value was calculated and the study was conducted. As for the frequency related to stress, the values of Alpha and SMR, Low Beta, and High Beta were analyzed. Brainwave analysis affects stress depending on the emotional state, and "fear" emotions cause anxiety by raising Beta levels, resulting in higher Mind Stress levels, while "joy" emotions lower Beta levels, resulting in a significant drop in Mind Stress.

Long-Term Clinical and Radiologic Outcomes after Stent-Graft Placement for the Treatment of Late-Onset Post-Pancreaticoduodenectomy Arterial Hemorrhage (췌십이지장절제술 후 발생한 후기 출혈에서 스텐트-그라프트를 이용한 치료의 장기적 임상, 영상의학적 결과)

  • Woo Jin Kim;Chang Ho Jeon;Hoon Kwon;Jin Hyeok Kim;Ung Bae Jeon;Suk Kim;Hyung Il Seo;Chang Won Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.600-612
    • /
    • 2021
  • Purpose To evaluate the long-term radiologic and clinical outcomes of stent-graft placement for the treatment of post-pancreaticoduodenectomy arterial hemorrhage (PPAH) based on the imaging findings of stent-graft patency and results of liver function tests. Materials and Methods We retrospectively reviewed the medical records of nine consecutive patients who underwent stent-graft placement for PPAH between June 2012 and May 2017. We analyzed the immediate technical and clinical outcomes and liver function test results. Stent-graft patency was evaluated using serial CT angiography images. Results All stent-grafts were deployed in the intended position for the immediate cessation of arterial hemorrhage and preservation of hepatic arterial blood flow. Technical success was achieved in all nine patients. Eight patients survived after discharge, and one patient died on postoperative day 28. The median follow-up duration was 781 days (range: 28-1766 days). Follow-up CT angiography revealed stent-graft occlusion in all patients. However, serum aspartate aminotransferase or alanine aminotransferase levels in all patients were well below those observed in hepatic infarction cases. Conclusion Stent-graft placement is a safe and effective treatment method for acute life-threatening PPAH. Liver function and distal hepatic arterial blood flow were maintained postoperatively despite the high incidence of stent-graft occlusion observed on follow-up CT.

Radiofrequency Ablation of Papillary Thyroid Microcarcinoma: A 10-Year Follow-Up Study (갑상선 미세유두암의 고주파 절제술 후 10년 경과 관찰)

  • Yoo Kyeong Seo;Seong Whi Cho;Jung Suk Sim;Go Eun Yang;Woojin Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.914-922
    • /
    • 2021
  • Purpose To investigate the efficacy and safety of radiofrequency ablation (RFA) for papillary thyroid microcarcinoma (PTMC) after > 10 years of follow-up. Materials and Methods This study included five patients who underwent RFA to treat PTMCs (five lesions, mean diameter 0.5 cm, range 0.4-0.7 cm) between November 2006 and December 2009. The inclusion criteria were histopathologically confirmed PTMCs, a single PTMC lesion without extrathyroidal extension, no metastasis, and ineligibility or refusal to undergo surgery. RFA was performed by a single radiologist using a radiofrequency generator and an internally cooled electrode. We retrospectively analyzed the procedure-induced complications, serial changes in ablated tumors, recurrence, and local as well as lymph node metastasis based on data obtained from medical records and radiological images. Results The mean follow-up period was 130.6 months (range 121-159 months). Three patients underwent a single RFA session, and two patients underwent two RFA sessions. We observed no procedure-induced complications. Three tumors completely disappeared after ablation, and ablation of the other two tumors resulted in the formation of a small scar that showed long-term stability (mean duration 16.8 months, range 12-27 months). At the last follow-up, no patient showed recurrence or lymph node metastasis, and serum thyroglobulin levels were within normal limits in all patients. Conclusion RFA may be effective and safe to treat low-risk PTMC in patients who refuse or are ineligible for surgery.

Feasibility and Safety of a Technique Intended to Place the Catheter Tip in the Right Atrium without Abutment Against the Cardiac Wall during Implantation of the Totally Implantable Venous Access Port (완전이식형 정맥 접근 포트 삽입 시 카테터 팁을 심벽에 닿지 않고 우심방 내 위치시키는 방법의 타당성과 안전성)

  • Hyejin Park;Tae-Seok Seo;Myung Gyu Song;Woo Jin Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.161-170
    • /
    • 2024
  • Purpose To assess the safety and feasibility of intentionally positioning the catheter tip in the right atrium (RA) without an abutment during implantation of a totally implantable venous access port (TIVAP). Materials and Methods We enrolled 330 patients who had undergone TIVAP implantation between January and December 2016 and postoperative chest CT. The TIVAP was placed using the single-incision technique to access the axillary vein directly from the incision line. To position the catheter tip in the RA without abutment, blood return was checked before cutting. Catheter length and complications were evaluated by retrospectively reviewing medical images and records. Results All patients achieved successful catheter tip positioning without abutment or dysfunction. The median tip position was 15.3 mm distal to the cavoatrial junction (CAJ) on fluoroscopy and 6 mm distal to the CAJ on CT. Catheter tips migrated a median of 10.4 mm cephalically on CT compared to fluoroscopy. Thromboses were detected in the RA and superior vena cava in one patient each. Conclusion Intentional catheter tip positioning in the RA without abutment is a safe and feasible technique with a low incidence of thrombosis and no observed dysfunction.

The Evaluation of the dose calculation algorithm(AAA)'s Accuracy in Case of a Radiation Therapy on Inhomogeneous tissues using FFF beam (FFF빔을 사용한 불균질부 방사선치료 시 선량계산 알고리즘(AAA)의 정확성 평가)

  • Kim, In Woo;Chae, Seung Hoon;Kim, Min Jung;Kim, Bo Gyoum;Kim, Chan Yong;Park, So Yeon;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.321-327
    • /
    • 2014
  • Purpose : To verify the accuracy of the Ecilpse's dose calculation algorithm(AAA:Analytic anisotropic algorithm) in case of a radiation treatment on Inhomogeneous tissues using FFF beam comparing dose distribution at TPS with actual distribution. Materials and Methods : After acquiring CT images for radiation treatment by the location of tumors and sizes using the solid water phantoms, cork and chest tumor phantom made of paraffin, we established the treatment plan for 6MV photon therapy using our radiation treatment planning system for chest SABR, Ecilpse's AAA(Analytic anisotropic algorithm). According to the completed plan, using our TrueBeam STx(Varian medical system, Palo Alto, CA), we irradiated radiation on the chest tumor phantom on which EBT2 films are inserted and evaluated the dose value of the treatment plan and that of the actual phantom on Inhomogeneous tissue. Results : The difference of the dose value between TPS and measurement at the medial target is 1.28~2.7%, and, at the side of target including inhomogeneous tissues, the difference is 2.02%~7.40% at Ant, 4.46%~14.84% at Post, 0.98%~7.12% at Rt, 1.36%~4.08% at Lt, 2.38%~4.98% at Sup, and 0.94%~3.54% at Inf. Conclusion : In this study, we discovered the possibility of dose calculation's errors caused by FFF beam's characteristics and the inhomogeneous tissues when we do SBRT for inhomogeneous tissues. SBRT which is most popular therapy method needs high accuracy because it irradiates high dose radiation in small fraction. So, it is supposed that ideal treatment is possible if we minimize the errors when planning for treatment through more study about organ's characteristics like Inhomogeneous tissues and FFF beam's characteristics.

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

Shear bond strength and debonding failure mode of ceramic brackets according to the surface treatment of porcelain (도재 표면 처리가 따른 세라믹 브라켓의 전단 접착 강도 및 탈락 양상)

  • Lee, Jeong-Nam;Lee, Cheol-Won
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.803-812
    • /
    • 1998
  • The purpose of this study was to evaluate the shear bond strength and failure mode of ceramic brackets according to the surface treatment of porcelain. Sixty Porcelain samples were randomly divided into six groups of ten samples. Then they were treated as follows: Group 1(silane only), Group 2(etching+silane), Group 3(stone+silane), Group 4(sandblasting+silane), Group 5(stone +etching+silane), Group 6(sandblasting+etching+silane) After surface treatment of porcelain, sixty Transcend 6000 brackets were bonded to the prepared porcelain surface and they were stored in $37^{\circ}C$ saline for 24 hours. An Instron universal testing machine was used to test the shear bond strength of ceramic brackets to porcelain. After debonding, bases of ceramic brackets and porcelain surfaces were examined under scanning electron microscope(SEM) to determine failure mode. Statistical analysis of the data was carried out with one-way ANOVA and Duncan's multiple range test. The results were as follows : 1. The shear bond strength of surface-treated groups 2 to 6 was higher than that of only silane-treated group 1, and there was statistical significance. (P<0.05) 2. There was no significant difference among the groups 3 to 6. (P>0.05) 3. The shear bond strength of etching-surface treated group 2 was significantly lower than those of sandblasting-surface treated group 4, complex surface treated group 5 and group 6. 4. According to the scanning electromicroscopic images, the surface roughness of sandblasting-surface treated group 4 was less than those of the group 5 and 6, but there was no significant difference in the shear bond strength. (P>0.05) As a conclusion we can have a clinically adequate bond strength when an application of silane is done after the treatment of porcelain surface with more than one way to bond ceramic bracket on the porcelain. Also, it is considered that the sandblasting and application of silane is effective for the simplication and convenience of the treatment.

  • PDF

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

Omental Infarction Following Laparoscopy-assisted Gastrectomy (LAG) for Gastric Cancer (위암 환자의 복강경 위절제술 후 발생한 그물막 경색의 임상적 의의)

  • Kim, Min-Chan;Jung, Ghap-Joon;Oh, Jong-Young
    • Journal of Gastric Cancer
    • /
    • v.10 no.1
    • /
    • pp.13-18
    • /
    • 2010
  • Purpose: Omental infarction (OI) following laparoscopy-assisted gastrectomy (LAG) for gastric cancer could become more common in the future because the indications for LAG are expected to expand. The aim of this study was to determine the clinical characteristics of OI following LAG. Materials and Methods: Three hundred ninety patients who underwent LAG for T1 or T2 gastric cancer from April 2003 to November 2007 were enrolled. OI was diagnosed by two radiologists using the patients' abdominal 16 row-detector CT scans. The clinicopathologic characteristics were retrospectively evaluated in the omental infarction (OI) group and the non-omental infarction (non-OI) group using the gastric cancer database of Dong-A University Medical Center and the medical record. Results: Nine omental infarctions (2.3%) of 390 LAGs were diagnosed. All the OIs could be discriminated from omental metastasis on the initial or follow up CT images. The location of the omental infarctions was on the epigastrium in 3 patients and in the left upper quadrant in 3 patients. The mean size of the OIs was 4.1 cm. Most patients with OI had no signs or symptoms. The body mass index of the OI group was higher than that of the non-OI group (P=0230), and OI was more common in patients who underwent total gastrectomy than in the patients who underwent subtotal gastrectomy (P=0.0011). Conclusion: Laparoscopy-assisted gastrectomy (LAG) with partial omentectomy for gastric cancer can be a cause of secondary OI. Omental infarction after LAG has different clinical characteristics and CT findings that those of other omental infarctions or postoperative omental metastases. Further multicenter study will be needed to evaluate in detail the clinical features of omental infarction after LAG.