• Title/Summary/Keyword: medical exchange

Search Result 396, Processing Time 0.022 seconds

The Exchange of Acupuncture&Moxibustion in the 18th Century between Korea and Japan -Based of the Joseon TongShinSa (Emissary)'s Record of Catechism on Medicine- (18세기 한일 침구학의 교류 - 조선통신사 의학문답기록을 중심으로 -)

  • Oh, Jun-Ho;Cha, Wung-Seok
    • Korean Journal of Acupuncture
    • /
    • v.23 no.2
    • /
    • pp.1-18
    • /
    • 2006
  • Objectives: The subject of this research is the catechism on medicine between the doctors of Joseon and Japan in the 18th century through Choson Delegation(朝鮮通信使 ). Methods: The author intended to review and analyze the contents of catechism related to Acupuncture and Moxibustion and determined the characteristics of Joseon and Japan ?s Acupuncture and Moxibustion. Results: At the time, Japanese doctors had a grasp on most theories of Acupuncture and Moxibustion and were very specialized clinically. They usually used filiform needles with various techniques, and already they had many different schools in practice. However, they wanted to know if their Acupuncture and Moxibustion skills were up to the international standard, especially to Joseon, whom they regarded as a country advanced in Acupuncture and Moxibustion. They wanted to com- pare and contrast their Acupuncture and Moxibustion with Joseon's. 18th century Joseon was high time for Acupuncture and Moxibustion. Various tools were used in surgery, and varieties of needles were used to stimulate acupuncture points. The development of tools evinces the precision of Joseon's Acupuncture and Moxibustion at the time. Also, comprehensive works such as DongUiBoGam(東醫寶鑑) and UiHaklpMun( 醫學入門) greatly influenced Acupuncture and Moxibustion. Because of this impact, it can be deduced that Acupuncture and Moxibustion emphasizing Jang(臟) and Bu(腑) organs and Internal Injury developed greatly. In addition, acupuncturist Holm(許任)'s fame continued from the 17th century into the 18th century, and his medical practice left a huge mark on not only Joseon but other eastern Asian countries as well. Conclusions: We found out the evidences that there were a lot of exchanges of acupuncture and moxibustion between Korea and Japan based of the Joseon TongShinSa (Emissary)'s record of catechism on medicine in the 18th century.

  • PDF

Cholesteryl Ester Transfer Protein (CETP) Deficiency and CETP Inhibitors

  • Mabuchi, Hiroshi;Nohara, Atsushi;Inazu, Akihiro
    • Molecules and Cells
    • /
    • v.37 no.11
    • /
    • pp.777-784
    • /
    • 2014
  • Epidemiologic studies have shown that low-density lipoprotein cholesterol (LDL-C) is a strong risk factor, whilst high-density lipoprotein cholesterol (HDL-C) reduces the risk of coronary heart disease (CHD). Therefore, strategies to manage dyslipidemia in an effort to prevent or treat CHD have primarily attempted at decreasing LDL-C and raising HDL-C levels. Cholesteryl ester transfer protein (CETP) mediates the exchange of cholesteryl ester for triglycerides between HDL and VLDL and LDL. We have published the first report indicating that a group of Japanese patients who were lacking CETP had extremely high HDL-C levels, low LDL-C levels and a low incidence of CHD. Animal studies, as well as clinical and epidemiologic evidences, have suggested that inhibition of CETP provides an effective strategy to raise HDL-C and reduce LDL-C levels. Four CETP inhibitors have substantially increased HDL-C levels in dyslipidemic patients. This review will discuss the current status and future prospects of CETP inhibitors in the treatment of CHD. At present anacetrapib by Merck and evacetrapib by Eli Lilly are under development. By 100mg of anacetrapib HDL-C increased by 138%, and LDL-C decreased by 40%. Evacetrapib 500 mg also showed dramatic 132% increase of HDL-C, while LDL-C decreased by 40%. If larger, long-term, randomized, clinical end point trials could corroborate other findings in reducing atherosclerosis, CETP inhibitors could have a significant impact in the management of dyslipidemic CHD patients. Inhibition of CETP synthesis by antisense oligonucleotide or small molecules will produce more similar conditions to human CETP deficiency and may be effective in reducing atherosclerosis and cardiovascular events. We are expecting the final data of prospective clinical trials by CETP inhibitors in 2015.

An Analysis on the Effect of the Increase in the Fee of Magnetic Resonance Imaging Deciphering of the External Hospital: Focusing on the Brain Magnetic Resonance Imaging (MRI 외부병원 판독 수가 인상의 효과 분석: 뇌 관련 자기공명영상을 중심으로)

  • Kim, Logyoung;Sakong, Jin;Jo, Minho;Wee, Seah;Lee, Jinyong;Kim, Yongkyu
    • Health Policy and Management
    • /
    • v.31 no.3
    • /
    • pp.261-271
    • /
    • 2021
  • Background: In 2018, the government increased the fee for the magnetic resonance imaging (MRI) image deciphering services of the external hospital to discourage the redundant MRI scan and to induce appropriate use of the MRI services. It is important to evaluate the effect of the policy to provide the basis for establishing other MRI-related policies. Methods: The healthcare data of the patients who had brain MRI scans were organized by episode and analyzed using the panel study in order to find out the effect of the MRI-related policy on the substitution effect and the medical expenses. Results: As a result of the increase in the fee of deciphering the MRI image, there has been an uplift in deciphering the MRI scan of the external hospital. It implies that more hospitals chose to use the MRI scan taken by other clinics or hospitals, rather than the MRI scan taken at their own facilities. Conclusion: The research results imply that a policy that facilitates the exchange of the medical image data between the hospitals is needed in order to establish an efficient management system of the healthcare resources. Such improvement is expected to reduce the social cost and contribute to the stability in the finance of national health insurance.

Study on the Factors Affecting the Intention to Share Electronic Medical Records (전자의무기록 공유 의도에 영향을 미치는 요인 연구)

  • Young Eun Kim;Jee Yeon Lee
    • Journal of the Korean Society for information Management
    • /
    • v.41 no.1
    • /
    • pp.283-311
    • /
    • 2024
  • This study examined the factors affecting the intention of the public to share electronic medical records(EMR) based on the theory of reasoned action and the privacy calculus model. It also investigated whether the purpose of EMR sharing varies depending on personal characteristics, such as the degree of interest in health and personal medical history. According to an online survey of 145 people, altruistic enjoyment, awareness of personal information protection, recognition of legal and institutional roles, and interest in health had a positive impact on the level of EMR sharing, and trust in hospitals positively adjusted the relationship between recognition of legal and institutional roles and sharing intentions. Accordingly, we confirmed that the public recognized the role of the government and hospitals in the sharing process as necessary. The public interest benefits of sharing are critical to activating public participation in the sharing of EMR, and it is also essential to prepare guidelines that legally guarantee the security and proper use of EMR.

Comparative study of 82Sr separation/purification methods used at Brookhaven National Laboratory and ARRONAX

  • Ha, Yeong Su;Yoon, Sang-Pil;Kim, Han-Sung;Kim, Kye-Ryung
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.2
    • /
    • pp.71-78
    • /
    • 2019
  • Nuclear imaging is one of the most powerful measures for non-invasive diagnosis of myocardial vascular disease. Radionuclide such as 13N, 15O, 201Tl and 82Rb is used for the measurement of cardiac blood flow. 13N, 15O and 201Tl are produced in cyclotrons while 82Rb is obtained from generator. Rubidium (Rb), an alkali ion, behaves biologically like potassium, and accumulates in myocardial tissue. Rb has rapid blood clearance profile which allows the use of 82Rb with a short physical half-life of 75 s for non-invasive evaluation of regional myocardial perfusion. There are several advantages of 82Rb over other radioisotopes. An ultra-short half-life significantly reduces the exposure of patients to radiation and allows to repeat injections for studying the effects of medical intervention. As a positron emitter, 82Rb allows positron emission tomography (PET) imaging which have shown superior diagnostic performances. 82Rb can be produced from generator by decay of its parent 82Sr. However, the preparation of 82Sr is difficult, because appropriate purity is required to meet the specification of the product. Recently reported procedure from ARRONAX research institute showed that a Chelex-100 resin is sufficient for this purpose and additional column is not necessary. Whereas Brookhaven National Laboratory (BNL) procedure contains three ion exchange resin separation, including Chelex-100 resin. Currently, since 82Sr production site is non-existent in Korea, Korea Atomic Energy Research Institute (KAERI) has plan to produce 82Sr within specifications. We compared 82Sr purification procedures reported from ARRONAX and BNL to investigate the most suitable procedure for our conditions.

The study on dose variation due to exchange of Upper and Lower jaw in the linear accelerator (선형가속기에서 상위조리개와 하위조리개의 교환에 의한 선량 변화의 고찰)

  • Lim CK.;Kim HN.;Song KW.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.6-10
    • /
    • 1999
  • The field size can be beam output, therefore MonitorUnit can be varied due to field size dependence The purpose of this study is to evaluate and compare the dose variation according to exchange of collimator The measurements were perfomed with Wellhofer dosimetry system(water phantom. ion chamber. electrometer. system controller. build up cap. etc)and two types of linear accerlerator (Mevatron KD, MevatronMX) Scatter can be affected to field size dependence and scatter correction is separated into collimator and phantom components, scatter components can affect by exchanging of collimator Measurements of collimator scatter factor(Sc) was done in air with build up cap. 1)Square field (5cm2 to 40cm2) was measured 2)and then keeping the upper jaw constant at loom and varing lower jaw from 5cm to 40cm, 3)keeping the lower jaw constant at 10cm and varing upper jaw from 5cm to 40cm Measurements of total scatter factor(Scp) was done in water at Dmax as the procedure of collimator scatter factor measurements in water Dmax The total scatter factors were obtained to the following equation(Sp=Scp/Sc) The measured data is normalized to the data of reference field size($10{\times}10$), rectangular field is inverted to equivalent field to compare three field size data As the collimator setting is varied, the output was changed In conclusion, the error was obtained small but it must be eliminated if we intend to reach the common stated goal of $5\%$ overall uncertainty in dose determination

  • PDF

Enhancement of Gas Transfer Efficiency in an Intravascular Lung Assist Device using Blood Substitutes (혈관내의 폐보조장치에서 혈액대용물질을 사용한 기체전달 효율향상)

  • 김기범;박재관;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.391-399
    • /
    • 2003
  • Intravascular oxygenation represents an attractive. alternative support modality for therapy originated with acute respiratory distress syndrome(ARDS). However. the clinical study concluded that more gas exchange was needed for intravascular oxygenation to be clinically effective in ARDS treatment. In this study, we tried to enhance gas exchange on the VIVLAD using microencapsulation of hemoglobin and perfluorocarbon emulsion(PFC emulsion). Blood gas measurements were performed by collecting blood samples from the arterial and venous sides of the circuit, and processing them in a blood/gas analyzer. The function of hemosome. blood/hemosome mixed solution. and blood/PFC emulsion mixed solution were tested by an oxygen dissociation curve using a blood/gas analyzer. As a result, it was shown that the oxygen transfer of hemosome and blood/hemosome mixed solution were higher than that of whole blood. Also. it showed that the carbon dioxide transfer of whole blood/PFC emulsion mixed solution was higher than that of others. Therefore, we determined that hemosome and PFC emulsion could increase oxygen transfer and carbon dioxide transfer. respectively.

Development of a Management Tool of CCD/CCR-centric Standard Clinical Document (CCD/CCR 중심의 표준진료문서 관리 도구의 개발)

  • Lee, In-Keun;Cho, Hune;Kim, Hwa-Sun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.507-514
    • /
    • 2012
  • XML-based standards such as CCD(Continuity of Care Document) and CCR(Continuity of Care Record) have been developed for representation, integration, and exchange of personal health record(PHR), and various of researches on PHR based on the standards have been conducted. These researches have developed and used CCD/CCR parsers each with their own different ways, but it can be hard to develop and update the parsers because of the structural complexity of the standards. Moreover, inter-exchange between CCD and CCR documents in the PHR-related medical information systems should be possible for the interoperability of the systems. Therefore, we proposed a designing method to develop the tools treating XML-based CCD/CCR documents. And we implemented CCD/CCR parser based on the proposed method and developed a converter from CCD to CCR using the parsers. To confirm the usefulness of the developed tool, we performed an experiment of creating CCD documents using the personal health data gathered from chronically ill patients in Kyungpook National University Hospital and of converting from the CCD documents to CCR documents.

Transmitting/Receiving of Standard Health Data Using Bluetooth HDP on the Android Platform (안드로이드에서 블루투스 HDP를 이용한 표준건강정보의 송수신)

  • Park, Young-Jin;Cho, Hui-Sup;Son, Jong-Wuk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.5
    • /
    • pp.464-470
    • /
    • 2013
  • These days, with increasing interest about the health care, research about standard for transmitting/receiving data of health device has been actively conducted. Standardization and testing / certification is underway through the IEEE 11073 PHD, Health Level Seven and the Continua Health Alliance, it'll continue to be more research and experiments in the future. In this paper, we introduce the IEEE 11073 PHD standards for exchange of remote health information and the Bluetooth Health Device Profile(HDP) for health device profile of the Bluetooth technology, also we conducted experiments about exchange health information between health device and smart device which are adapted the IEEE 11073 PHD and Bluetooth HDP. Transmitting/receiving of the IEEE 11073 PHD standard protocol using the Bluetooth HDP profile between health device and smart device can be known by this experiment, and it expect to implement variety of remote medical services through health device supporting these standards in future.

Temperature-Range-Dependent Optimization of Noninvasive MR Thermometry Methods (온도범위에 따른 비침습적 자기공명 온도측정방법의 최적화)

  • Kim, Jong-Min;Kumar, Suchit;Jo, Young-Seung;Park, Joshua Haekyun;Kim, Jeong-Hee;Lee, Chulhyun;Oh, Chang-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.241-250
    • /
    • 2015
  • Noninvasive temperature monitoring is feasible with Magnetic Resonance Imaging (MRI) based on temperature sensitive MR parameters such as $T_1$ and $T_2$ relaxation times, Proton Resonance Frequency shift (PRFs), diffusion, exchange process, magnetization transfer contrast, chemical exchange saturation transfer, etc. While the temperature monitoring is very useful to guide the thermal treatment such as RF hyperthermia or thermal ablation, the optimization of the MR thermometry method is essential because the range of temperature measurement depends on the choice of the measurement methods. Useful temperature range depends on the purpose of treatment methods, for example, $42^{\circ}C$ to $45^{\circ}C$ for RF hyperthermia and over $50^{\circ}C$ for thermal ablation. In this paper, MR thermometry methods using $T_1$ and $T_2$ relaxation times and PRFs-based MR thermometry are tried on a 3.0 T MRI system and their results are reported and compared. In addition, the scanning protocol and temperature calculation algorithms from $T_1$ and $T_2$ relaxation times and PRFs are optimized for the different temperature ranges for the purpose of RF hyperthermia and/or thermal ablation.