• Title/Summary/Keyword: medical equipment

Search Result 1,262, Processing Time 0.03 seconds

A Study on the Strategy of IoT Industry Development in the 4th Industrial Revolution: Focusing on the direction of business model innovation (4차 산업혁명 시대의 사물인터넷 산업 발전전략에 관한 연구: 기업측면의 비즈니스 모델혁신 방향을 중심으로)

  • Joeng, Min Eui;Yu, Song-Jin
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.2
    • /
    • pp.57-75
    • /
    • 2019
  • In this paper, we conducted a study focusing on the innovation direction of the documentary model on the Internet of Things industry, which is the most actively industrialized among the core technologies of the 4th Industrial Revolution. Policy, economic, social, and technical issues were derived using PEST analysis for global trend analysis. It also presented future prospects for the Internet of Things industry of ICT-related global research institutes such as Gartner and International Data Corporation. Global research institutes predicted that competition in network technologies will be an issue for industrial Internet (IIoST) and IoT (Internet of Things) based on infrastructure and platforms. As a result of the PEST analysis, developed countries are pushing policies to respond to the fourth industrial revolution through cooperation of private (business/ research institutes) led by the government. It was also in the process of expanding related R&D budgets and establishing related policies in South Korea. On the economic side, the growth tax of the related industries (based on the aggregate value of the market) and the performance of the entity were reviewed. The growth of industries related to the fourth industrial revolution in advanced countries overseas was found to be faster than other industries, while in Korea, the growth of the "technical hardware and equipment" and "communication service" sectors was relatively low among industries related to the fourth industrial revolution. On the social side, it is expected to cause enormous ripple effects across society, largely due to changes in technology and industrial structure, changes in employment structure, changes in job volume, etc. On the technical side, changes were taking place in each industry, representing the health and medical sectors and manufacturing sectors, which were rapidly changing as they merged with the technology of the Fourth Industrial Revolution. In this paper, various management methodologies for innovation of existing business model were reviewed to cope with rapidly changing industrial environment due to the fourth industrial revolution. In addition, four criteria were established to select a management model to cope with the new business environment: 'Applicability', 'Agility', 'Diversity' and 'Connectivity'. The expert survey results in an AHP analysis showing that Business Model Canvas is best suited for business model innovation methodology. The results showed very high importance, 42.5 percent in terms of "Applicability", 48.1 percent in terms of "Agility", 47.6 percent in terms of "diversity" and 42.9 percent in terms of "connectivity." Thus, it was selected as a model that could be diversely applied according to the industrial ecology and paradigm shift. Business Model Canvas is a relatively recent management strategy that identifies the value of a business model through a nine-block approach as a methodology for business model innovation. It identifies the value of a business model through nine block approaches and covers the four key areas of business: customer, order, infrastructure, and business feasibility analysis. In the paper, the expansion and application direction of the nine blocks were presented from the perspective of the IoT company (ICT). In conclusion, the discussion of which Business Model Canvas models will be applied in the ICT convergence industry is described. Based on the nine blocks, if appropriate applications are carried out to suit the characteristics of the target company, various applications are possible, such as integration and removal of five blocks, seven blocks and so on, and segmentation of blocks that fit the characteristics. Future research needs to develop customized business innovation methodologies for Internet of Things companies, or those that are performing Internet-based services. In addition, in this study, the Business Model Canvas model was derived from expert opinion as a useful tool for innovation. For the expansion and demonstration of the research, a study on the usability of presenting detailed implementation strategies, such as various model application cases and application models for actual companies, is needed.

A Study on Reduction of Radiation Exposure by Nuclear Medicine Radiation Workers (핵의학 방사선 작업종사자 피폭 감소 방안에 대한 연구)

  • Lee, Wanghui;Ahn, Sungmin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.271-281
    • /
    • 2019
  • This study investigated the shielding efficiency of various types of shielding materials and measured the dose by organ using the phantom. Results of Shielding Efficiency Measurement Using Personal Radiation Meter. Among the various shielding materials, 1.1 mm RNS-TX composed of nano tungsten showed the highest shielding efficiency and 0.2 mm lead shielding showed the lowest shielding efficiency. 99mTc 30 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 20.53 mSv without radiation protective clothing, 8.75 mSv when wearing 0.25 mm Pb protective clothing, 6.03 mSv when wearing 0.5 mm Pb protective clothing. 131I 2 mCi mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 7.71 mSv without radiation protective clothing, 4.88 mSv when wearing 0.25 mm Pb protective clothing, 2.79 mSv when wearing 0.5 mm Pb protective clothing. 18F 5 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 16.39 mSv without radiation protective clothing, 15.84 mSv when wearing 0.25 mm Pb protective clothing, 12.52 mSv when wearing 0.5 mm Pb protective clothing. None of the radiation workers working in the nuclear medicine department exceeded the dose limit. However, when compared with other workers in the hospital, they showed a relatively high dose. Therefore, it is necessary to prepare measures to reduce and manage the dose of radiation workers in the nuclear medicine department through the wearing of radiation protective clothing made of lightweight, shielding material with good shielding efficiency, circulation task, task sharing, and substitution equipment such as auto dispenser.

A Study on Hospital Infection Management of Radiological Technologist (방사선사의 병원감염관리에 대한 연구)

  • Jeong, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.727-735
    • /
    • 2018
  • Targeting the radiological technologists working in Gyoungsangnam province, this study was performed to obtain the fundamental data to improve the competency and right awareness of the hospital infection management, and to educate infection management of radiological technologists by analyzing the status, awareness, and performance of the hospital infection management. During April 1, 2018 to April 31, 2015, after we sent out a total of 400 questionnaires for the survey to radiological technologists working at the clinic located in Gyoungsangnam province, 320 questionnaires suitable for research were analysis by using SPSS 18.0 statistical analysis software. As the hospital infection management factors, 5 items for hospital infection and 60 items of the awareness and performance for the hospital infection management were used. 60 items of the awareness and performance for the hospital infection management were consisted hand hygiene, personal hygiene and clothing, medical equipment and supplies, cleaning and waste, examination and environment. And as the sociodemographic characteristics, the gender, marriage, age, level of education, working organization, working period, and working department were used. Consequentially, the awareness for the hospital infection management($4.19{\pm}.60$) and the performance($4.22{\pm}.52$) were confirmed as high level. Using these results, the hospital infection management level of the radiological technologists working in Gyoungsangnam province was found to be high in arareness and performance of hospital infection management. There was a significant correlation between the degree of awareness and performance of radiological technologists for hospital infection management. Furthermore, in the multiple regression analysis of cognitive factors on performance, it was found that 66.1% explanatory power had a significant positive influence. In order to improve the awareness of hospital infection management of radiological technologist working in various departments, the infection management education and improvement of hospital work environment are necessary. And also, It is important to participate actively in hospital infection management and preventive education and to play a pivotal role in securing expertise in hospital infection management.

A Study on Contents Activism Analysis using Social Media - Focusing on Cases Related to Tom Moore's 100 Laps Challenge and the Exhibition of the Statue of Peace - (소셜미디어를 활용한 콘텐츠 액티비즘 분석 연구 - 톰 무어의 '100바퀴 챌린지'와 '평화의 소녀상' 전시를 중심으로-)

  • Shin, Jung-Ah
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.8
    • /
    • pp.91-106
    • /
    • 2021
  • The purpose of this study is to define the process of leading to self-realization and social solidarity through the process of contents planning, production, and distribution as Contents Activism, and to categorize specific execution steps. Based on this, we try to analyze concrete cases to find out the social meaning and effect of the practice of Contents Activism. As for the research method, after examining the differences between traditional activism and Contents Activism through a review of previous studies, the implementation process of Contents Activism was categorized into 7 steps. By applying this model, this study analyzed two cases of Contents Activism. The first case is the 100 laps challenge in the backyard planned by an elderly man ahead of his 100th birthday in early 2020, when the fear of COVID-19 spread. Sir Tom Moore, who lives in the UK, challenged to walk 100 laps in the backyard to help medical staff from the National Health Service as COVID-19 infections and deaths increased due to a lack of protective equipment. His challenge, which is difficult to walk without assistive devices due to cancer surgery and fall aftereffects, drew sympathy and participation from many people, leading to global solidarity. The second case analyzes the case of 'The Unfreedom of Expression, Afterwards' by Kim Seo-kyung and Kim Woon-seong, who were invited to the 2019 Aichi Triennale special exhibition in Japan. The 'Unfreedom of Expression, After' exhibition was a project to display the Statue of Peace and the lives of comfort women in the Japanese military, but it was withdrawn after three days of war due to threats and attacks from the far-right forces. Overseas artists who heard this news resisted the Triennale's decision, took and shared photos in the same pose as the Statue of Peace on social media such as Twitter and Instagram, empathizing with the historical significance of the Statue of Peace. Activism, which began with artists, has expanded through social media to the homes, workplaces, and streets of ordinary citizens living in various regions. The two cases can be said to be Contents Activism that led to social practice while solidifying and communicating with someone through contents.

Heavy concrete shielding properties for carbon therapy

  • Jin-Long Wang;Jiade J Lu;Da-Jun Ding;Wen-Hua Jiang;Ya-Dong Li;Rui Qiu;Hui Zhang;Xiao-Zhong Wang;Huo-Sheng Ruan;Yan-Bing Teng;Xiao-Guang Wu;Yun Zheng;Zi-Hao Zhao;Kai-Zhong Liao;Huan-Cheng Mai;Xiao-Dong Wang;Ke Peng;Wei Wang;Zhan Tang;Zhao-Yan Yu;Zhen Wu;Hong-Hu Song;Shuo-Yang Wei;Sen-Lin Mao;Jun Xu;Jing Tao;Min-Qiang Zhang;Xi-Qiang Xue;Ming Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2335-2347
    • /
    • 2023
  • As medical facilities are usually built at urban areas, special concrete aggregates and evaluation methods are needed to optimize the design of concrete walls by balancing density, thickness, material composition, cost, and other factors. Carbon treatment rooms require a high radiation shielding requirement, as the neutron yield from carbon therapy is much higher than the neutron yield of protons. In this case study, the maximum carbon energy is 430 MeV/u and the maximum current is 0.27 nA from a hybrid particle therapy system. Hospital or facility construction should consider this requirement to design a special heavy concrete. In this work, magnetite is adopted as the major aggregate. Density is determined mainly by the major aggregate content of magnetite, and a heavy concrete test block was constructed for structural tests. The compressive strength is 35.7 MPa. The density ranges from 3.65 g/cm3 to 4.14 g/cm3, and the iron mass content ranges from 53.78% to 60.38% from the 12 cored sample measurements. It was found that there is a linear relationship between density and iron content, and mixing impurities should be the major reason leading to the nonuniform element and density distribution. The effect of this nonuniformity on radiation shielding properties for a carbon treatment room is investigated by three groups of Monte Carlo simulations. Higher density dominates to reduce shielding thickness. However, a higher content of high-Z elements will weaken the shielding strength, especially at a lower dose rate threshold and vice versa. The weakened side effect of a high iron content on the shielding property is obvious at 2.5 µSv=h. Therefore, we should not blindly pursue high Z content in engineering. If the thickness is constrained to 2 m, then the density can be reduced to 3.3 g/cm3, which will save cost by reducing the magnetite composition with 50.44% iron content. If a higher density of 3.9 g/cm3 with 57.65% iron content is selected for construction, then the thickness of the wall can be reduced to 174.2 cm, which will save space for equipment installation.

Relation between Ablation Execution Time and Radiation Exposure Effect in the Treatment of Atrial-fibrillation using Cryo-balloon and 3D Radio-frequency Ablation (냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.427-434
    • /
    • 2022
  • Atrial fibrillation treatment includes 3D RFCA and Cryo-balloon ablation. Both procedures have in common that they enter after understanding the structure of the heart using angiography equipment. Therefore, there is a disadvantage that the effect of exposure according to the procedure time can be a threat to both the patient and the operator, so this study aims to confirm the relationship between the total ablation time and the effect of radiation exposure. We used follow-up data (retrospective) from 41 patients who underwent coronary angiography and arrhythmia at the same time from March 2019 to July 2022. The range for total ablation time was based on the recorded data from the start to the end of the total ablation. The end point of 3D RFCA was when the ablation was completed for 4 pulmonary veins, and in the case of Cryo-balloon ablation, the data that succeeded in electrical insulation were included. As a result of analyzing the total ablation time, the time taken for Cryo-balloon ablation was 1037.29±103.66 s, which was 2448.61 s faster than 3D RFCA using 3485.9±405.71 s, and was statistically significant. (p<0.05) As a result of analyzing the total fluoroscopy time, the exposure time for 3D RFCA was 2573.75±239.08 s, which was less by 1717.15 s than the exposure time for Cryo-balloon ablation, 4290.9±420.42 s, and was statistically significant. In the case of total area dose product, 3D RFCA was 59.04±13.1 uGy/m2, which was lower than Cryo-balloon ablation 980.6±658.07 uGy/m2 by 921.56 uGy/m2, which was statistically significant. As the insulation time of the Cryo-balloon ablation is shorter than that of the 3D RFCA, the method using the Cryo-balloon ablation is considered to be effective when the patient's condition is not good and a quick procedure is required. However, in patients with permanent Atrial fibrillation, there is a high probability of structural changes in the heart, so it is considered that 3D RFCA is better than Cryo-balloon ablation, which is difficult to manipulate.

Effects of Changes in Collimation Size and the sub ROI on Exposure Index of Hand Radiography (손 방사선검사에서 조사야 크기와 보조관심영역 변화가 노출지수 값에 미치는 영향)

  • Young-Cheol Joo;Dong-Hee Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.851-857
    • /
    • 2023
  • The purpose of this study is to investigate the effect of changes in collimation size and sub ROI on exposure index(EI) in hand radiography, present collimation size and EI suitable for average hand size of Koreans, and present the effect of changes in sub ROI on EI. The subjects of this study were hand-wrist phantom, and the exposure conditions were set to 55 kVp, 125, mA, and 6.25 mAs, and source to image receptor distance was applied to 110 cm. Based on the vendor recommended sub-ROI (18.7" × 18.7", 8" × 10", 8" × 7.4", 6" × 7.4")and the textbook's recommended sub-ROI 8" × 10", each obtaining 30 images, and comparing the EI shown in the equipment. The EI according to the change in the size of the collimation were 1663.7±4.52, 8"×10" is 1489.1±4.49, 8"×7.4" is 1716.9±3.00, 6"×7.4" is 168.7±3.66 for each EI, and the average value of each value was statistically significant. The average EI according to the sub ROI change was 1489.1±4.49 for SS, LS was 1694.8±5.19 for AEC, 2052.9±5.96, VR was 1548.3±3.20, and HR was 1663.2±4.33. The appropriate field size considering the hand size of Koreans was found to be 8"×7.4". In addition, when the field size increases based on the generally known field size (8"×10") during hand radiography, the EI value changes from a maximum of 15% to a minimum of 11%, and the sub ROI shape based on sub ROI 'SS' Depending on the change, the EI value increased from a maximum of 37% to a minimum of 3%.

Comparative Analysis of Community Health Practitioner's Activities and Primary Health Post Management Before and After Officialization of Community Health practitioner (보건진료원의 정규직화 전과 후의 보건진료원 활동 및 보건진료소 관리운영체계의 비교 분석)

  • Yun, Suk-Ok;Jung, Moon-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.19 no.2
    • /
    • pp.141-158
    • /
    • 1994
  • To provide better health care services to the rural population, the government has made the Community Health Practitioner(CHP) a regular government official from April 1, 1992. This study was carried out to study the impact of officialization of CHP on the activities and management system of Primary Health Post(PHP). Fifty PHPs were selected by two stage sampling, cluster and simple random, from 595 PHPs in Kyungnam and Kyungpook provinces. Data were collected by a personal interview with CHPs and review of records and reports kept in the PHPs. The study was done for the periods of January 1-March 31, 1992 (before officialization) and January 1-March 31, 1993 (after officialization). Ninety-six percent of the CHPs wanted to become a regular government official in the hope of better job security and higher salary. The proportion of CHPs who were proud of their iob was increased from 24% to 46% after officialization. Those CHPs who felt insecure for their job decreased from 30% to 10%. Monthly salary was increased by 34% from 802,600 Won to 1,076,000 Won and 90% of the CHPs were satisfied with their salary, also more CHPs responded that they have autonomy in their work planning, implementation of plan, management of the post, and evaluation of their activity. There were no appreciable changes in such CHPs' activities as assessment of local health resources, drawing map for the catchment area, utilization of community organization, grasping the current population structure in the catchment area, keeping the family health records, individual and group health education, and school health service. However, the number of home visits was increased from 13.6 times on the average per month per CHP to 27.5 times. More mothers and children were referred to other medical facilities for the immunization and family planning services. Average number of patients of hypertension, cancer, and diabetes in three months period was decreased from 12.7 to 11.6, from 1.5 to 1.2, and 4.3 to 3.4, respectively. Records for the patient care, drug management, and equipment were well kept but not for other records. The level of record keeping was not changed after officialization. The proportion of PHPs which had support from the health center was increased for drug supply from 14.0% to 30.0%, for consumable commodities from 22.0% to 52.0%, for maintenance of PHP from 54.0% to 68.0%, for supply of health education materials from 34.0% to 44.0%, and supply of equipment from 54.0% to 58.0%. Total monthly revenue of a PHP was increased by about 50,000 Won; increased by 22,000 Won in patient care and 34,700 Won in the government subsidy but decreased in the membership due and donation. However, there was no remarkable changes in the expenditure. The proportion of PHPs which had received official notes from the health center for the purpose of guidance and supervision of the CHPs was increased from 20% to 38% during three months period and the average number of telephone call for supervision from the health center per PHP was increased from 1.8 to 2.1 times(p<0.01). However, the proportion of PHPs that had supervisory visit and conference was reduced from 79% to 62%, and from 88% to 74%, respectively. The proportion of CHPs who maintained a cooperative relationship with Myun Health Workers was reduced from 42% to 36%, that with the director of health center from 46% to 24%, that with the chief of public health administration section from 56% to 36%, and that with the chairman of PHP management council from 62% to 38%. Most of the CHPs (92% before and 82% after officialization) stated that the PHP management council is not helpful for the PHP. CHPs who considered the PHP management council unnecessary increased from 4% to 16%(p<0.05). Suggestions made by the CHPs for the improvement of CHP program included emphasis on health education, assurance of autonomy for PHP management, increase of the kind of drugs that can be dispensed by CHPs, and appointment of an experienced CHP in the health center as the supervisor of CHPs. The results of this study revealed that the role and function of CHPs as reflected in their activities have not been changed after officialization. However, satisfaction in job security and salary was improved as well as the autonomy. Support of health center to the PHP was improved but more official notes were sent to the PHPs which required the CHPs more paper works. Number of telephone calls for supervision was increased but there was little administrative and technical guidance for the CHP activities.

  • PDF

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF