• 제목/요약/키워드: medical doctors

검색결과 1,663건 처리시간 0.033초

학생(學生)의 건강행위(健康行爲), 신념(信念), 가치(價値) 및 보건의료(保建醫療) 이용(利用)에 미치는 영향(影響)에 관(關)한 연구 -가족(家族)의 형태(形態) 및 제특성(諸特性)을 중심(中心)으로- (A Study of the Relationship to the Student's Health Behavior, Belief, Value and Health Service Utilization -With Emphasis on Family Structure and Other Variables-)

  • 정연강
    • 한국학교보건학회지
    • /
    • 제6권1호
    • /
    • pp.9-44
    • /
    • 1993
  • An explorative and descriptive study in order to determine the effect of family structure and other socio-demographic variables on health behavior, belief, locus, and value and utilization of public health service was carried out. Data were collected from 1,653 subjects randomly sampled in three areas, Seoul, Kyunggi province, and Cheju province. From Seoul 849 subjects were selected, 397 subjects Kyunggi, and 407 subjects from Cheju, respectively. Self-reporting questionaires were administered during the period from March to June, 1992. The major findings were as follows: 1) The subjects visited herb-doctor's at irregular intervals mainly to have tonic medicine prepared. They preferred herb-doctor's rather than with doctors at clinics and hospitals. Statistically significant difference was found among the regions studied (p<0.05). 2) The reason for visiting hospitals was primarily for treatment of diseases. They preferred hospital because they felt that the hospitals offer much highly reliable treatment services as well as medical accessibility. For the purpose of hospital utilization, statistically significant differences existed among sex, educational level, family type and region. However, no significance was found among sex, educational level, and region (p<0.05). 3) The subjects utilized general hospitals mainly for diagnosis and treatment of diseases. They preferred general hospitals because of their much better facilities and reliability. Statistical significance was found among sex, educational level, and region (p<0.05). 4) The subjects visited dentist at irregular intervals basis. They visited once half a year or three to four months. their purpose of visit was mainly for diagnosis and treatment of diseases. Statistical significance differences were found among educational level, region and economic standard (p<0.05). 5) Whenever their illnesses were mild and the pharmacies was located in nearby they visited to pharmacies. They visited once a month and patient medicines. Statistically significant differences were found among sex, educational level and region (p<0.05). 6) The subjects believed that herb medicine was quite efficacious for treatment of some diseases, particularly by information handed down through time-honored tradition and experience. However, they recognized that the efficacy of folk medicine can vary with type and severity of diseases. Statistical significance was among sex, educational level, region and economic standard (p<0.05). 7) The reason why subjects believed that pray and superstition are effective for treatment of certain type of diseases, particularly in neuropathy, was the belief in God's almighty. Statistically significant differences were found among sex, educational level, regions and economic standard (p<0.05). 8) Most of subjects under same condition preferred western medicine because they believed that it is more scientific and prompts in showing therapeutic effect. Statistical significance was not found in the choice of type of public health service among, regions. But significant differences were found among sex, educational level and region (p<0.05). 9) The subjects looked for pharmacy if they thought the symptom was mild. However, they visited hospitals for chronic disease and general hospitals for emergency treatment. Statistical significances were found among educational level, region and economic standard (p<0.05). 10) Although most of students wanted to have a healthy life as for the component of health standard and value, they think that they are not healthy (p<0.05). As for the health behavior, significant difference was found in the proportion of smoking and drinking between educational level and region (p<0.05). The health locus was affected by educational level, and health behavior was influenced by region, sex and educational level. The utilization of type of public health service was influenced by family type and region, and health belief by region and educational level, and the health values by region and economic standard respectively, most of correlation showed statistical significance. Among them, the highest correlation was seen between locus of control and external/internal locus of control, which is quite obvious. The correlation between health belief and behavior was the next highest, but still low (0.343). All the other variables are low but significant except only a few of those. These findings indicate that health education should be incorporated into the curriculum so as to develop desirable health habit, and ability of self-control in accordance with their growth stages. A systematic and scientific understanding on the herb/folk medicine is needed, and greater reliability of the utilization of public health services are is still required. Health policy for equal distribution of health service throughout the country along the hierarchical health service system and complementary mutual assistance and cooperation among various health organizations are also required.

  • PDF

두 종합 병원을 방문한 영유아 양육자의 이유식에 대한 인지도 조사 (Survey on the Awareness of Guardians of Young Infants on the Weaning of Food in Pohang and Gyeongju Area)

  • 위현우;서유경;김애숙;이선주;조성민;이동석;김두권;최성민
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제9권2호
    • /
    • pp.233-241
    • /
    • 2006
  • 목 적: 저자들은 이유식에 대한 인지도를 설문조사를 통하여 조사하고, 영유아의 체중 증가와는 어떠한 관계가 있는지 알아보고자 하였다. 방 법: 2005년 9월 1일부터 2005년 12월 1일까지 동국대학교 소아과 외래를 방문한 6개월에서 18개월까지의 영유아의 양육자 141명을 대상으로 설문 조사를 실시하였다. 이유식에 대한 인지도에 관한 항목 10문항의 응답별 분포를 파악하고 응답자 각각의 총점을 구하였으며, 대상 영유아의 체중 백분위수의 증감 여부를 알아보았다. 결 과: 이유식에 대한 정보를 얻는 방법이 '주위 사람들'인 응답이 62명(44.0%)으로 가장 많았고, '의사'가 3명(3.1%)으로 나타났으며, 이유식의 정의를 '밥과 같은 고형식을 먹이기 위한 준비단계'라고 답한 사람이 54명(38.3%)이었다. 이유식의 시작시기는 모유 수유를 하는 경우에는 '4~6개월'이라고 답한 사람이 31명(60.8%), 조제유 혹은 혼합수유를 하는 경우에는 '6~8개월'이 41명(45.6%), '4~6개월'이 40명(44.4%)으로 거의 비슷한 비중을 차지하였으며, 아기가 아토피피부염이 있거나 알레르기의 가족력이 있을 경우에는 '6~8개월' (45.4%)이라는 대답이 가장 많았다. 이유식을 주는 방법으로는 '숟가락' (90.8%), 이유식으로 가장 먼저 시작하기에 가장 좋은 음식은 '쌀미음, 죽' (78.7%), 이유식을 새로 추가하여 줄 때의 음식의 가짓수는 '1가지' (58.2%), 이유식을 새로 추가하여 줄 때의 시간 간격은 '4일~1주일' (50.3%), 이유식을 주는 시간대는 '모유나 조제유를 먹기 전에' (55.3%), 생우유를 주기 시작하는 시기는 '12개월 전후' (77.3%), 이유식을 주는 동안 설사, 구토, 발진과 같은 부작용이 일어났을 때의 대처방식으로는 '주던 이유식을 즉시 중단하되 증상이 호전되면 1~3개월 후 다시 시도한다' (85.1%)라고 바르게 답한 사람이 가장 많았다. 평균 점수는 6.21이었고, 각 응답자의 총점과 대상 아기들의 체중 증감 여부에 대한 상관관계에서는 통계적으로 유의성이 없었다. 결 론: 본 연구에서의 이유식에 대한 전체적인 인지도는 과거의 조사에서보다 개선되었으나, '의사'로부터 이유식 정보를 얻는 사람들이 점차 감소하는 것으로 나타났다. 이유식에 대한 인지도와 아기들의 체중 증감과의 관계는 유의하지 않았으나, 앞으로의 이유식에 관한 연구에서는 여러 변수를 배제할 수 있는, 보다 통제된 집단을 대상으로 연구를 시행하는 것이 필요하리라 생각된다.

  • PDF

일개 호스피스 병동에서 임종한 말기 폐암 환자의 임상적 고찰 (Clinical Characteristics of Terminal Lung Cancer Patients Who Died in Hospice Unit)

  • 김유진;이춘섭;이주리;이정호;홍영화;이태규;문도호
    • Journal of Hospice and Palliative Care
    • /
    • 제10권2호
    • /
    • pp.78-84
    • /
    • 2007
  • 목적: 본 연구는 오늘날 증가추세에 있는 폐암 환자에게 보다 체계적이고 효율적인 호스피스 완화의료를 위한 기초자료를 제공하고자 호스피스 병동에서 임종한 말기 폐암 환자의 임상적 특성을 조사하였다. 방법: 2003년 3월 1일부터 2006년 12월 31일까지 샘 안양병원 호스피스 병동에서 말기 폐암으로 임종한 129명의 환자를 대상으로 하여 이들의 의무기록을 후향적으로 조사하였다. 수집된 자료는 실수와 백분율, 빈도와 중간 값으로 제시하였으며 호스피스 완화의료 동안의 생존기간은 SPSS 13.0의 Kaplan-Meier방법으로 분석하였다. 결과: 129명의 말기 암 환자 중 남자 93명(72%), 여자 36명(28%), 연령의 중간 값은 68세(범위 $37{\sim}93$세)이었다. 진통제를 복용하고 있었던 환자는 82명(64%)이었으며 그렇지 않은 환자는 47명(36%)이었다. 입원 이유는 호흡곤란이 47명(36%)으로 가장 많았고 이는 일반적으로 말기 암환자의 입원이유가 통증인 것과 다르게 나타났다. 호스피스 병동 입원 후 120명(93%)의 환자에게 마약성 진통제를 사용하였고 주사용 모르핀(103명, 80%)이 가장 많이 처방되었다. 진정제를 사용한 환자는 87명(67%)이었으며 미다졸람을 가장 많이 사용하였다(68명, 53%). 호스피스 완화의료 동안의 생존기간의 중간 값은 35일, 입원 일수의 중간 값은 24일이었다. 결론: 말기 폐암환자에서 호흡곤란의 조절은 매우 중요하며 말기 폐암 환자에 대한 호스피스 완화의료의 기간이 짧아서 효과적인 호스피스 완화의료를 위해서는 가족과 환자에게 지속적인 교육과 홍보가 필요하다고 생각된다.

  • PDF

한의표준임상진료지침 개발을 위한 유방암 보완치료 실태조사 (A Survey on Treatment of Breast Cancer Patients with Korean Medicine: Preliminary Research for Clinical Practice Guidelines)

  • 김남훈;강나훈;유은실;박남춘;이진욱;박경선;이진무;이창훈;장준복;장보형;황덕상
    • 대한한방부인과학회지
    • /
    • 제31권4호
    • /
    • pp.165-178
    • /
    • 2018
  • 목 적: 한의사의 유방암 보완치료에 대한 실태를 조사하고 임상진료지침의 필요성을 알아보고자 본 연구를 시행하였습니다. 방 법: 본 연구는 e mail 설문지를 사용하였으며 유방암 환자 치료 여부, 내원환자들의 병기, 증상, 진단, 치료, 기타 의견 등을 설문하였습니다. 결 과: 322명이 응답하였으며 그 중 84명이 해당 기관에서 유방암 치료를 시행하고 있었습니다. 내원 환자들의 주된 호소는 피로 및 전신 소력감이었고 변증 및 맥진을 주된 진단법으로 한약 및 침뜸을 중심으로 치료하고 있다고 응답하였습니다. 유방암의 한의학적 보완치료로서 임상진료지침이 필요하다고 생각하며 개발된다면 적극적으로 사용하겠다고 응답하였습니다. 결 론: 유방암 보완치료 실태조사를 통해 임상진료지침에 대한 필요성을 알 수 있었으며 추가적인 연구가 필요합니다.

일 대학 병원의 가정간호시범사업 서비스 내용 및 만족도에 대한 조사연구 (A study on Hospital based Home Health Care Service and the Level of Client Satisfaction)

  • 김정남;권영숙;고효정;김명애;박청자;신영희;이병숙;이경희;서향숙
    • 한국보건간호학회지
    • /
    • 제14권2호
    • /
    • pp.246-259
    • /
    • 2000
  • The purpose of this study was to assess the provided home health care services and to evaluate the patient's satisfaction level of received home health care services. Well trained two home health care nurses interviewed with 138 respondents who received home health care by Keimyung University Hospital from January 1st to August 31st 1999. The results were summarized as follows : 1) Among 138 respondents, $55.8\%$ were mail and $44.2\%$ were female and $70.3\%$ of them were over sixty years old. Respondents main family care givers were spouse$(53.6\%)$, daughters and sons$(36.2\%)$ and parents$(7.2\%)$. 2) $60.2\%$ of cancer patients received home health care services, $23.3\%$ of cerebral­cardiovascular patients, $7.5\%$ of endocrine disorder patients, $2.3\%$ of those who have indwelling foley catheter patients, $1.5\%$ of those who have respiratory problems and others$(5.2\%)$. 3) $88.1\%$ of respondents were satisfied with the number of home visits they received. $50.5\%$ of respondents' were received 1 to 3 times of home visits by home health care nurse per month. $48.6\%$ of respondents answered they were introduced by attending doctors or nurses to home health care services. $55.8\%$ of respondents answered registration to home health care services was simple and easy. $97.4\%$ of respondents answered home health care payment system was adequate. $64.9\%$ of respondents answered the cost of home health care per visit was adequate and comfortable. 4) Health education, counselling, physical assessment was provided to most of the patients. Those who suffered with cerebral-cardiovascular disease was needed hands on direct care most of all. The least home health care service provided was medication. 5) The satisfaction measurement tool was composed with 13 items and 3 score scale. The mean score of satisfaction on provided home health care services was 2.67 out of 3. Among 13 items. 'home health care service was kind enough' was highest(2.84). 'nurse use precise word to understand and communicate'. 'nurse gave home visiting notice ahead of time and kept the home visiting promise on time' was 2.83. 'whenever I need home health care nurse I can give a call and meet the nurse' was lowest 2.41. Special Home Health care programs such as comprehensive hospice care programs for elders over sixty years old should be organized. Adequate and standardized home health care payment system should be developed as soon as possible. In korean family situation. when family members are getting sick and stay at home. family members were taking care of the patients. special program such as counselling family members are needed.

  • PDF

공공보건의료사업 수행과 주민특성이 공공병원 이미지에 미치는 영향 (The Effects of Performance of Public Health Services and Personal Characteristics on Community Image of Public Hospitals)

  • 심인옥;황은정
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.6089-6098
    • /
    • 2015
  • 본 연구는 33개 공공병원을 대상으로 공공보건의료사업 수행관련 특성과 관할 지역주민의 특성에 따른 지역주민 이미지와의 관련성을 분석한 상관관계 조사연구이다. 본 연구에서 활용된 자료는 보건복지부에서 수행한 '2011년 지역거점 공공병원 운영평가'를 통해 수집된 이차자료 중 본 연구의 목적에 부합하는 자료를 일부 추출하여 수행기관의 승인을 득한 후 활용하였다. 연구대상자는 114에 등록되어 있는 해당지역 주민들로, 연구의 목적에 대한 설명을 제공한 후 참여를 허락한 지역주민을 대상자로 하였다. 자료수집 기간은 2011년 3월~9월까지였다. 본 연구에 참여한 최종 대상자 수는 총 1,789명으로, 남자 891명(49.80%), 여자 898명(50.20%)이었다. 본 연구 대상자의 일반적 특성별로 공공병원에 대해 긍정적 이미지군과 부정적 이미지군 간에 유의한 차이를 보인 변수는 연령(p<.001), 최종 교육형태(p<.001), 직업유무(p<.05), 월평균 수입(p<.001), 1년 이내에 해당 공공병원 이용경험 여부(p<.001)이었다. 공공병원에 대해 지역주민 이미지에 유의한 영향을 미치는 변수는 연령(OR=0.34, 95% CI=0.19-0.60), 최종 교육형태(OR=3.03, 95% CI=1.60-5.76), 최근 1년 이내 해당 공공병원 이용경험(OR=0.57, 95% CI=0.40-0.81), 건강수준(OR=0.69, 95% CI=0.49-0.96), 거주 지역유형(OR=2.10, 95% CI=1.11-3.99), 지역주민 1,000명당 공공보건의료사업 실적(OR=0.58 95% CI=0.35-0.96)으로 나타났다. 중앙정부와 광역정부, 지방정부는 공공병원으로 하여금 공공보건의료사업을 원활히 수행할 수 있도록 제도적, 재정적으로 꾸준히 지원해야 할 것이다. 아울러 공공병원도 지역주민이 원하는 바를 지속적으로 확인하고 이를 공공보건의료사업 서비스 개선에 반영하여 공공기관에 대한 긍정적 이미지가 지역주민들에게 형성될 수 있도록 노력해야 할 것이다.

전인적 호스피스간호중재 프로그램이 입원한 호스피스환자의 통증과 불안에 미치는 효과 (Effects of Wholistic Hospice Nursing Intervention Program on Pain and Anxiety for In-patient of Hospice Palliative Care Unit)

  • 최성은;강은실;최화숙
    • 호스피스학술지
    • /
    • 제8권1호
    • /
    • pp.55-67
    • /
    • 2008
  • 목적: 말기환자와 그 가족들은 신체적인 고통뿐 아니라 심리·사회적, 영적 측면에서 전인적인 고통을 겪고 있으므로 이러한 고통을 완화시켜주기 위해서는 간호사, 의사, 성직자, 사회복지사 등의 다학제(multi- discipline) 전문가들과 자원봉사자로 구성된 호스피스 팀에 의해 제공되는 호스피스 간호중재 프로그램의 개발이 필요한 현실이다. 본 연구는 단일군 전․후 유사실험 연구설계로 전인적 호스피스 간호중재 프로그램이 호스피스 병동에 입원한 호스피스 환자의 통증과 상태불안에 미치는 효과를 알아보고자 하였다. 방법: 자료수집은 P시 소재 S병원의 호스피스 병동에 입원한 18세 이상의 환자 27명을 대상으로 2004년 4월 6일부터 2005년 4월 20일까지 구조화된 설문지를 통해 수집하였다. 제공된 전인적 호스피스간호중재 프로그램은 전인적, 다학제적, 개별 및 집단적인 중재형태로 구성되어 있고, 상호협동적인 다학제 전문가팀(간호사, 의사, 성직자, 사회복지사, 무용치료사, 미술치료사, 자원봉사자)이 호스피스 대상자 병실이나 병동에서 매회 120분씩, 총 10회(총1,200분)에 걸쳐 실시한 프로그램이었다. 프로그램 효과를 측정하기 위한 도구로서 통증 척도는 윤영호(1998) 등이 한국형 간이통증 조사지(Korean Version of Brief Pain Inventory, BPI-K)로 개발한 도구 중 일부를 윤매옥(2000)이 사용한 도구, 상태불안 척도로는 Spielberger (1975)의 상태불안 측정도구(State-Anxiety Inventory)를 김정택과 신동균(1978)이 번역하여 사용한 도구를 사용하였다. 자료분석은 수집된 자료를 SPSS/WIN 12.0 프로그램을 이용하여 실수, 백분율, 최대값, 최소값, 평균, 표준편차, Paired t-test로 분석하였다. 결과: 본 연구의 결과는 다음과 같다. (1) 가설 1 ‘전인적 호스피스 간호중재 프로그램을 제공받은 입원 호스피스 환자(이하 실험군)는 실험 전보다 실험 후의 통증 정도가 낮을 것이다’ 를 검증한 결과 실험군은 실험 후의 통증 점수가 유의하게 낮아 가설이 지지되었다(t=-10.585, P= .000). (2) 가설 2 ‘전인적 호스피스 간호중재 프로그램을 제공받은 실험군은 실험 전보다 실험 후의 상태불안 정도가 낮을 것이다’ 를 검증한 결과 실험군은 실험 후의 상태불안 정도가 유의하게 낮아 가설이 지지되었다(t=-8.234, P= .000). 결론: 본 연구의 결과, 전인적 호스피스 간호중재 프로그램은 호스피스 대상자의 통증 및 상태불안을 완화시키고 향상시켜 신체 및 정서적 차원에서 그 효과가 확인되었으므로 호스피스 임상 실무에 적극적으로 활용할 수 있을 것이며, 그로 인해 호스피스 대상자의 통증을 조절하고 불안을 감소시켜 삶의 질을 총체적으로 높일 수 있는 데 기여하리라 사료된다.

  • PDF

한국의 세계기록유산 보존 현황 및 과제 (Preservation of World Records Heritage in Korea and Further Registry)

  • 김성수
    • 한국기록관리학회지
    • /
    • 제5권2호
    • /
    • pp.27-48
    • /
    • 2005
  • 이 논문은 한국의 세계기록유산에 대하여 먼저 그 의미와 가치를 재확인하고, 이들 세계기록유산에 대한 보존 관리 및 그 현황을 조사하며, 한국의 기록유산을 디지털화 하는데 있어서의 문제점과 해결책을 모색하고, 추후 한국의 기록유산 중 세계기록유산으로 등록되기를 희망하는 4종의 기록물들에 대한 가치와 의의를 고찰한 연구이다. 본 연구의 상세 사항은 다음과 같다. 첫째, 제2장에서는 한국의 세계기록유산에 대한 가치와 의의를 고찰하였다. 먼저 세계기록유산의 선정기준과 절차 등을 먼저 파악하고, 한국의 세계기록유산인 "훈민정음" "조선왕조실록" "승정원일기" "직지(백운화상초록불조직지심체요절(白雲和尙抄錄佛祖直指心體要節))"에 대하여 각각 그 가치와 의미를 분석하였다. 둘째, 제3장에서는 '한국의 세계기록유산 보존 관리 현황'에서는 세계기록유산을 보존하고 있는 <서울대학교 규장각> <국가기록원 부산기록정보센터> <간송미술관>의 기관별로 그 보존 관리 현황을 고찰하였다. 그 결과, 이 3기관 모두 세계기록유산 보존 관리 현황은 '매우 우수하다'고 평가할 수 있었다. 즉, 1)그 세부적인 보안대책이 완벽하다. 2)그 보존방법에 있어서도 항온 항습의 특별한 서고를 별도로 마련하고, 이 서고 내에서 다시 '오동나무 상자 서장(書欌)'을 설치한 후, 이들 상자와 서장 속에 세계기록유산을 납입하여 보존하고 있다. 3)방화장치와 서고조명 및 소독 등에도 철저를 기하고 있음 등을 파악하였다. 셋째, 제4장에서는 '한국의 기록유산 디지털화 과제'에 대하여 개괄적으로 고찰하였다. 그 결과, 한국 기록유산의 디지털작업 및 DB구축에서 '디지털화 표준'이 가장 중요한 문제이며, 이 문제의 해결을 위해서는 디지털화(Digitization)에 대한 총체적이고 표준적인 시스템의 개발이 시급함을 지적하였다. 그리고 국가기록관리시스템을 개발한 경험이 있는 <국가기록원>과 한국학 고기록물의 디지털화에 많은 관심을 가진 <문화재청>이 공동으로 노력하여, 한국학 관련 기록유산의 디지타이제이션(Digitization)에 대한 총체적이고 표준적인 시스템의 개발이 요구됨을 파악하였다. 넷째, 제5장 '세계기록유산 등록을 추후 희망하는 한국의 기록유산'에서는 한민족의 기록유산 중에서 차후 세계기록유산으로 등재되기를 희망하는 4종 즉, 1)<해인사 고려대장경 경판>, 2)"동의보감", 3)"삼국유사", 4)"무구정광대다라니경"의 기록물에 국한하여, 그 어떤 의미에서 세계적인 가치와 의의가 있는가를 고찰하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF