• Title/Summary/Keyword: medical device

Search Result 2,094, Processing Time 0.029 seconds

Surface Tribology of Total Ankle Joint Replacement (인공발목관절의 표면 마모 특성)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF

X-ray Medical Image Spatio-temporal Denoising Algorithm (엑스선 의료영상의 시공간 잡음제거 알고리즘)

  • Park, Sangwook;Joo, Hui Jin;Sohn, Jeongwoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.685-686
    • /
    • 2016
  • 엑스선 투시촬영장치와 같은 의료용 동영상의 잡음 제거에 있어서 시공간 잡음제거 알고리즘을 제안한다. 제안된 알고리즘에서는 무한 충격 응답 기반 시간 영역 잡음 제거 얄고리즘을 도입하여 움직임이 적은 영역에서는 자연스러운 잡음 제거가 가능하며 움직임이 많은 영역에서는 연산량 측면에서 효율성을 고려하여 지역적 평균 필터 기반 공간 잡음 제거 알고리즘을 적용하여 움직임에 의한 흐려짐 열화 현상을 최소화 하면서 잡음 제거를 수행하였다.

X-ray Medical Image Dynamic Range Adjustment Algorithm (엑스선 의료영상의 다이내믹 레인지 조절 알고리즘)

  • Park, Sangwook;Joo, Hui Jin;Sohn, Jeongwoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.683-684
    • /
    • 2016
  • 엑스선 영상의 명암 차를 조절하는 다이내믹 레인지 조절 알고리즘은 병변의 부위 크기를 진단하는데 직접적인 영향을 준다. 그러므로 의료 영상을 통한 정확한 진단을 위해 원본 영상의 왜곡없이 적절한 다이내믹 레인지로 조절하는 알고리즘은 의료 영상 획득의 중요한 과정 중 하나이다. 본 논문에서는 엑스선 의료영상의 다이내믹 레인지를 효과적으로 조절하는 알고리즘을 제시한다. 먼저 영상의 히스토그램 중에 최대값에 해당되는 밝기 값을 구한다. 다음으로 해당 밝기 값을 중심으로 적합한 로지스틱 함수를 적용하여 순람표를 만든다. 계산된 순람표를 적용하여 최종 밝기 값을 구하여 의료 진단에 최적인 다이내믹 레인지를 갖는 영상을 획득할 수 있었다.

A Study on Safety Management for Senior-Friendly Medical Devices (고령친화 의료기기의 안전관리방안 연구)

  • Lim, Kyeongmin;Song, Tongjin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.256-267
    • /
    • 2018
  • The number of items and the market size of the senior-friendly medical devices are rapidly increasing, and it is necessary to come up with a safety management plan for senior-friendly medical devices. We searched and analyzed the definition and policy of senior-friendly medical device, and classified medical device items of the Ministry of Food and Drug Safety, calculated market sizes and manufacturing export import results by classification, and investigated the current state of senior-friendly industry and the fields of its culture. In order to prepare a safety management plan, we reduce the number of items that need to be managed intensively by extracting 69 items for administration, that are substantially harmful to the elderly. As specific safety management plans of items for administration, we propose plans for introductions of readability-enhanced labeling, QR codes for cautions and manuals, universal design mandatory, UDI code system with considering a balanced viewpoint of the industry development.

Effects of Various Laser Wavelengths and Power Densities on the Ocular Damage in Pigmented Rats

  • Chung, Phil-Sang;Shin, Jang-In;Chang, Moo-Hwan;Chang, So-Young;Kang, Jung-Wook;Hwang, Hee-Jun;Ahn, Jin-Chul
    • Biomedical Science Letters
    • /
    • v.14 no.3
    • /
    • pp.173-178
    • /
    • 2008
  • With the widespread use of laser in medical and industrial settings, the incidence of laser injury to the ocular continues to grow among workers involved in handling lasers. The aim of this study is to compare ocular damages after irradiation with various laser wavelengths and power density. Ocular of pigmented rats was irradiated with $CO_2$ laser, 1064 nm Nd:YAG laser, and 532 nm diode laser. We observed damage of cornea, lens, and retina using slit lamp microscope and funduscopy. H&E staining of histopathology were applied to study the specimens. The higher exposure ($200mW/cm^2$, 10 sec) with $CO_2$ laser resulted in severe damage at the cornea. For the 1064 nm Nd:YAG laser, the higher exposure than $10mW/cm^2$ (10 sec) resulted in damage at the cornea and lens. Further, with the 532 nm diode laser, retinal lesions were induced when $10mW/cm^2$ (0.25 sec) was delivered to the eye. Theses results suggest that the ocular damages are different from various laser wavelength and power density.

  • PDF

Medical Contents Visualization System for Smart Device (스마트 기기용 의료 콘텐츠를 위한 영상 가시화 시스템)

  • Kwon, Koojoo;Kang, Dong-Su;Kho, Youngihn;Shin, Byeong-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.10
    • /
    • pp.1264-1272
    • /
    • 2012
  • Three-dimensional volume rendering method which shows the inside of human body is widely used in medical imaging area. Existing medical imaging system using a volume rendering method already has provided a variety of three-dimensional results. Recently existing results in the medical imaging among physicians and patients to facilitate communication have been studied since smart device which has advantage of portability applied in the medical imaging. In this paper, we propose 3D volume visualization system for a relatively low spec portable smart devices by using 2D textures and we also implements 2D diagnostic images of portable medical imaging visualization system.

AHP를 이용한 중소기업형 의료기기 개발사업의 선정

  • 조근태;하상도;김성민;염용권
    • Journal of Technology Innovation
    • /
    • v.8 no.2
    • /
    • pp.1-17
    • /
    • 2000
  • Recently, due to the primary emphasis of health industry and to the restriction of budget, setting the priorities for effective and efficient investment on the medical device and material products has been one of the critical issues in the government sector. This paper shows how an Analytic Hierarchy Process (AHP) model can be used for assessing selected medical device and material products for grant of the Ministry of Health & Welfare. The final results show that unabsorbable suture is the most attractive medical device product among 88 evaluated products, followed by IV cannula, central venous catheter.

  • PDF

U-Healthcare Patch Type Wireless Body Temperature Monitoring System (유헬스케어 패치형 무선 체온 모니터링 시스템 구현)

  • Park, Young-Sang;Kwon, Oeon;Cho, Hyun-Sung;Son, Jaebum
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.55-61
    • /
    • 2020
  • Recently, there have been many research on fever management using u-healthcare technology. Especially, fever of infants requires continuous monitoring of body temperature by parents. For infants between 4 weeks and under 5 years old, it is recommended to use an electronic thermometer or chemical thermometer in the axilla, or to use an infrared thermometer. However, in order to overcome the reality of not being able to waste significant time on continuous monitoring, there have been demands of patch type thermometers with the internet of things (IoT) and wireless communication technologies. Existing IoT thermometers are difficult to attach to infants' body because they do not take into account its size, and their interoperability is not guaranteed because they do not comply with standards in communication. Therefore, in this study, a patch-type thermometer with a diameter of 20 mm and a weight of 2.9 g was developed to manage the fever of infants, while it communicates wirelessly with Bluetooth Low Energy (BLE) communication protocol and complies with IEEE 11073 PHD(Personal Health Device) at the same time. We verified its performance under the requirements of thermometers regulated by the Korean Ministry of Food and Drug Safety.

Analysis on international trade flow of medical devices in Korea, China, and Japan (한.중.일 의료기기 무역분석)

  • Bae, Hong-Kyun
    • International Commerce and Information Review
    • /
    • v.14 no.4
    • /
    • pp.131-152
    • /
    • 2012
  • This study has analyzed the international trade flow of medical devices in Korea, China, and Japan more theoretically and systematically through a mutual connection of the medical device export structure of Korea and the import structure of China and Japan organically, with an intensity approach on the bilateral international trade flow. Also, it is meaningful to find a solution to boost exports of Korea to China and Japan. Therefore in this study, we recognize the importance of the medical device market in China and Japan, which is the main competition for Korea and its market, and look into the trade situation of these three countries. We also look into the relative market stream and the trade intensity of the main medical devices in Korea, China and Japan, and seek measures for the steady growth of the medical device market in these three countries.

  • PDF

Feasibility of the AtriClip Pro Left Atrium Appendage Elimination Device via the Transverse Sinus in Minimally Invasive Mitral Valve Surgery

  • Shirasaka, Tomonori;Kunioka, Shingo;Narita, Masahiko;Ushioda, Ryohei;Shibagaki, Keisuke;Kikuchi, Yuta;Wakabayashi, Naohiro;Ishikawa, Natsuya;Kamiya, Hiroyuki
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.383-388
    • /
    • 2021
  • Background: Achieving external access to and manual occlusion of the left atrial appendage (LAA) during minimally invasive mitral valve surgery (MIMVS) through a small right thoracotomy is difficult. Occlusion of the LAA using an epicardial closure device seems quite useful compared to other surgical techniques. Methods: Fourteen patients with atrial fibrillation underwent MIMVS with concomitant surgical occlusion of the LAA using double-layered endocardial closure stitches (n=6, endocardial suture group) or the AtriClip Pro closure device (n=8, AtriClip group) at our institution. The primary safety endpoint was any device-related adverse event, and the primary efficacy endpoint was successful complete occlusion of blood flow into the LAA as assessed by transthoracic echocardiography at hospital discharge. The primary efficacy endpoint for stroke reduction was the occurrence of ischemic or hemorrhagic neurologic events. Results: All patients underwent LAA occlusion as scheduled. The cardiopulmonary bypass and aortic cross-clamp times in the endocardial suture group and the AtriClip group were 202±39 and 128±41 minutes, and 213±53 and 136±44 minutes, respectively (p=0.68, p=0.73). No patients in either group experienced any device-related serious adverse events, incomplete LAA occlusion, early postoperative stroke, or neurologic complication. Conclusion: Epicardial LAA occlusion using the AtriClip Pro during MIMVS in patients with mitral valve disease and atrial fibrillation is a simple, safe, and effective adjunctive procedure.