Pressure Loss across Tube Bundles in Two-phase Flow (2상 유동 내 관군에서의 압력 손실)

  • Sim, Woo Gun;Banzragch, Dagdan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.181-189
    • /
    • 2016
  • An analytical model was developed by Sim to estimate the two-phase damping ratio for upward two-phase flow perpendicular to horizontal tube bundles. The parameters of two-phase flow, such as void fraction and pressure loss evaluated in the model, were calculated based on existing experimental formulations. However, it is necessary to implement a few improvements in the formulations for the case of tube bundles. For the purpose of the improved formulation, we need more information about the two-phase parameters, which can be found through experimental test. An experiment is performed with a typical normal square array of cylinders subjected to the two-phase flow of air-water in the tube bundles, to calculate the two-phase Euler number and the two-phase friction multiplier. The pitch-to-diameter ratio is 1.35 and the diameter of cylinder is 18mm. Pressure loss along the flow direction in the tube bundles is measured with a pressure transducer and data acquisition system to calculate the two-phase Euler number and the two-phase friction multiplier. The void fraction model by Feenstra et al. is used to estimate the void fraction of the two-phase flow in tube bundles. The experimental results of the two phase friction multiplier and two-phase Euler number for homogeneous and non-homogeneous two-phase flows are compared and evaluated against the analytical results given by Sim's model.

The Development of Confocal Microscopy Using the Amplified Double-compound Flexure Guide (레버 증폭 구조의 플렉서를 이용한 공초점 현미경의 개발)

  • Lee, Sang-Won;Kim, Wi-Han;Jung, Young-Dae;Park, Min-Kyu;Kim, Jee-Hyun;Lee, Sang-In;Lee, Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 2011
  • A confocal microscope was developed utilizing a scanning sample stage based on a home-built double-compound flexure guide. A scanning sample stage with nano-scale resolution consisted of a double leaf spring based flexure, a displacement amplifying lever, a Piezo-electric Transducer(PZT) actuator and capacitance sensors. The performance of the two-axis stage was analyzed using a commercial finite element method program prior to the implementation. A single line laser was employed as the light source along with the Photo Multiplier Tube(PMT) that served as the detector. The performance of the developed confocal microscope was evaluated with a mouse ear skin imaging test. The designed scanning stage enabled us to build the confocal microscope without the two optical scanning mirror modules that are essential in the conventional laser scanning confocal microscope. The elimination of the scanning mirror modules makes the optical design of the confocal microscope simpler and more compact than the conventional system.

A Study on Vibration & Noise Reduction of Fast Back Feeding Device for Manufacturing Process (제조공정용 Fast Back 이송장치 진동·소음 저감에 관한 연구)

  • Han, Doo-Hee;Lee, Seung-Hun;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.642-648
    • /
    • 2019
  • This paper presents a fast back-type transfer device for snack food processing that uses the inertia of transferred material. A conventional conveying system is a drive system that uses a belt conveyor and mechanical crank, which generate noise and vibration and cause environmental pollution. Vibration and noise are reduced in the proposed fast back feeding device by using a counterweight. The crank drive unit was replaced with a linear servomotor, and an equilibrium device was designed to balance the force due to acceleration. This makes it is possible to adjust the forward and backward speed and acceleration through PLC control. A vibration damper device offsets the vibration force of the periodic shock form. The main cause of the vibration was identified through vibration analysis, and reduction measures were established. We verified the effectiveness of the vibration by making a prototype and performing about 10 vibration tests. Because no mechanical transducer is needed, energy loss, noise, and vibration do not occur, and the operating speed is not limited.

Effects of Intermittent Sciatic Nerve Stimulation on the Soleus and Medial Gastrocnemius Muscle Atrophy in Hindlimb Suspended Rats

  • Park, Byung-Rim;Cho, Jung-Shick;Kim, Min-Sun;Chun, Sang-Woo
    • The Korean Journal of Physiology
    • /
    • v.26 no.2
    • /
    • pp.159-166
    • /
    • 1992
  • The present study was designed to evaluate effects of intermittent electrical stimulation of the sciatic nerve on the atrophic response of antigravity muscles, such as the soleus (slow m.) and medial gastrocnemius (fast m.) muscles. Rats (Sprague-Dawley, 245-255g) were subjected to a hindlimb suspension and divided into three groups : one was with hindlimb suspension (MS) and another with hindlimb suspension plus intermittent electrical stimulation of the sciatic nerve (HS ES). Control group (CONT) was kept free without strain of the hindlimb. After 7 days of hindlimb suspension, the soleus and medial gastrocnemius muscles were cut at their insertion sites, and were then connected to the force transducer to observe their mechanical properties. Optimal pulse width and frequency of electrical stimulation were 0.2ms, 20Hz for the soleus muscle and 0.3ms, 40Hz for the medial gastrocnemius muscle under supramaximal stimulation. Body weight and circumference of the hindlimb were significantly decreased in HS and HS-ES groups compared with the control group. In HS-ES group, however, the weight of the soleus muscle was not different from that in the control group while the weight of the medial gastrocnemius muscle was lower than that in the control group. In HS group, mechanical properties of muscle contraction including contraction time, half relaxation time, twitch tension, tetanic tension, and fatigue index of both muscles were significantly decreased compared with the control group except for twitch tension and tetanic tension of medial gastrocnemius muscle. The degree of atrophy of the soleus muscle in HS group was more prominent than that of the medial gastrocnemius muscle. Twitch tension and fatigue index of the soleus muscle and fatigue index of the medial gastrocnemius muscle in HS-ES group were not different from those of the control group. While mechanical properties of the soleus muscle examined were all significantly increased in HS-ES group compared with HS group, only contraction time and fatigue index of the medial gastrocnemius muscle were significantly increased in HS-ES group. These data indicate that intermittent electrical stimulation may be useful in prevention of muscle atrophy.

  • PDF

Effect of Major Factors on the Spray Characteristics of Ultrasonic Atomizing Nozzle (초음파 미립화 노즐의 분무 특성에 미치는 주요 인자의 영향)

  • Jeong, Seon Yong;Lee, Kye Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.1-7
    • /
    • 2017
  • The atomization of a liquid into multiple droplets has many important industrial applications, including the atomization of fuels in combustion processes and coating of surfaces and particles. Ultrasonic atomizing nozzle has a transducer that receives electrical input in the form of a high frequency signal from a power generator and converts that into mechanical energy at the same frequency. Liquid is atomized into a fine mist spray using high frequency sound vibrations. In coating applications, the unpressurized, low-velocity spray reduces the amount of overspray significantly because the droplets tend to settle on the substrate, rather than bouncing off it. The spray can be controlled and shaped precisely by entraining the slow-moving spray in an ancillary air stream using specialized types of spray-shaping equipment. The desired patterns of spray can be obtained using an air stream. To simulate the water mist behavior of an ultrasonic atomizing nozzle using an air stream, the Lagrangian dispersed phase model was employed using the commercial code FLUENT. The effects of the nozzle contraction shape, water droplet size and the pneumatic pressure drop on the spray characteristics were investigated to obtain the optimal condition for coating applications.

Acoustic Emission (AE) Technology-based Leak Detection System Using Macro-fiber Composite (MFC) Sensor (Macro fiber composite (MFC) 센서를 이용한 음향방출 기술 기반 배관 누수 감지 시스템)

  • Jaehyun Park;Si-Maek Lee;Beom-Joo Lee;Seon Ju Kim;Hyeong-Min Yoo
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.429-434
    • /
    • 2023
  • In this study, aimed at improving the existing acoustic emission sensor for real time monitoring, a macro-fiber composite (MFC) transducer was employed as the acoustic emission sensor in the gas leak detection system. Prior to implementation, structural analysis was conducted to optimize the MFC's design. Consequently, the flexibility of the MFC facilitated excellent adherence to curved pipes, enabling the reception of acoustic emission (AE) signals without complications. Analysis of AE signals revealed substantial variations in parameter values for both high-pressure and low-pressure leaks. Notably, in the parameters of the Fast Fourier Transform (FFT) graph, the change amounted to 120% to 626% for high-pressure leaks compared to the case without leaks, and approximately 9% to 22% for low-pressure leaks. Furthermore, depending on the distance from the leak site, the magnitude of change in parameters tended to decrease as the distance increased. As the results, in the future, not only will it be possible to detect a leak by detecting the amount of parameter change in the future, but it will also be possible to identify the location of the leak from the amount of change.

Effects of $Ca^{2+}-antagonists$ on the electrical activity of guinea-pig taenia coli (결장뉴 전기활동도에 대한 칼슘 길항제의 영향)

  • Kim, Ki-Whan;Kim, Woo-Gyeum
    • The Korean Journal of Physiology
    • /
    • v.19 no.1
    • /
    • pp.1-13
    • /
    • 1985
  • The influences of $Ca^{2+}-antagonists$, verapamil and $Mn^{2+}$, upon the spontaneous electrical activity and contractions were studied in guinea-pig taenia coli. Spontaneous contractions were recorded with force transducer, and spike action potentials were measured extracellularly by use of suction electrode. All experiments were performed in tris-buffered Tyrode solution Which was aerated With 100% $O_2$ and kept at $35^{\circ}C$. The results obtained were as follows : 1) Verapamil suppressed the frequency and amplitude of spontaneous contractions dose dependently, and blocked completely mechanical responses at the concentration of 1 mg/1. 2) The frequency of bursts of spike discharge(bursts frequency) and the number of spikes in a burst(spikes frequency) were reduced in a dose·dependent manner within the concentration range of $10^{-5}$ to $10^{-3}g/l$, and bursts frequency was affected more readily at a low concentration of $10^{-5}g/l$ verapamil. 3) The verapamil_induced suppression of spontaneous contractions in the Tyrode solution containing 1 mM $Ca^{2+}$ was completely antagonized by the addition of extra $Ca^{2+}$ to the Tyrode solution $(2\;m\;MCa^{2+})$. 4) $Mn^{2+}$ suppressed the amplitude of spontaneous contractions, whereas $Mn^{2+}$ accelerated the frequency dose-dependently within the range of low concentrations$(10^{-7}\;to\;10^{-4}\;M\;Mn^{2+})$. 5) The bursts frequency determining frequency of spontaneous contractions was increased in a dose-dependent manner, whereas the spikes frequency known to determine the contractions amplitude was reduced within the range of low concentrations. At a high concentration of 1 mM $Mn^{2+}$, however, all spontaneous contractile responses were blocked simultaneously with the disapperance of electrical activity. 6) The frequency and amplitude of spontaneous contractions altered by $Mn^{2+}$ in 1mM $Ca^{2+}$ Tyrode were increased by extra $Ca^{2+}(2mM)$.

  • PDF

Evaluation of Fatigue Damage of Metal Matrix Composite by LFB Acoustic Microscopy (Line-Focus-Beam 초음파 현미경을 이용한 금속복합재료의 피로손상에 관한 연구)

  • Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.2
    • /
    • pp.40-47
    • /
    • 1993
  • Composites composed of a precipitation harden 2124 alloy matrix reinforced by SiC whiskers, which are fabricated by powder metallugy, are suscepttible to fatigue damage due to the pile-up of moving dislocation and the microcrack initiation along SiC-Al interfaces, especially at the external surfaces of a body. The initial process, such as pile-up of dislocation or microcrack, that corresponds to the stage I during fatigue failure process are too small to be detected and characterized by conventional ultrasonic technique. This paper describes the applicability of an acoustic microscope with Line-Focus-Beam(LFB) lens of 225MHz to evaluate fatigue damage of SiC whiskers reinforced Al alloy. The specimens which were 6.6mm thick, 13mm wide, and 105mm long in the gage section were fatigued in tension-tension under load control. The velocity of leaky surface and leaky pseudosurface acoustic waves are obtained by FFT analysis technique from V(z) curve which is a record of output of piezoelectric transducer. These results are discussed with the change of number of fatigue cycles. The result obtained by acoustic microscope is compared with that by ultrasonic technique generated at 5MHz with conventional surface wave transducers.

  • PDF

Non-contact Ultrasonic Technique for the Evaluation Wall Thinning of the Plate (박판의 두께감육 평가를 위한 비접촉 유도초음파 검사 기법)

  • Park, Ik-Keun;Kim, Hyun-Mook;Kim, Tae-Hyung;Kim, Yong-Kwon;Cho, Yong-Sang;Song, Won-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.287-293
    • /
    • 2005
  • Ultrasonic guided waves are gaining increasing attention for the inspection of platelike and rodlike structures. At the same time, inspection methods that do not require contact with the test piece are being developed for advanced applications. This paper capitalizes on recent advances in the areas of guided wave ultrasonics and noncontact ultrasonics to demonstrate a superior method for the nondestructive detection of defects thinning simulating hidden corrosion in thin aluminum plates. The proposed approach uses EMAT(electro-magnetic acoustic transducer) for the noncontact generation and detection of guided waves. Interesting features in the dispersive behavior of selected guided modes are used for the detection of plate thinning. It is shown that mode cutoff measurements provide a qualitative detection of defects thinning. Measurement of the mode group velocity can be also used to quantify depth thinning.

A Study on the Guided Wave Mode Conversion using Self-calibrating Technique (자가교정기법에 의한 유도초음파 모드전이에 관한 연구)

  • Park, Jung-Chul;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.3
    • /
    • pp.206-212
    • /
    • 2000
  • The guided wave mode conversion phenomena were investigated for the NDE of a plate-like structure with thickness variation. The ratios of reflection and transmission (R/T) were measured via the self-calibrating procedure which allows us to obtain experimental guided wave data in a more reliable way regardless of the coupling uncertainty between transducer & specimen. The results on R/T could be used to determine the thickness reduction of the structure. It was shown that not only the incident modes but also the converted ones need to be considered in the self-calibrating guided wave inspection to extract a reasonable correlation between experimental data & the thickness variation. Through this study, the potential of guided wave inspection as a quantitative NDE technique was explored based on the combined concept of self-calibration & multi-mode conversion in guided wave scattering problems.

  • PDF