• 제목/요약/키워드: mechanical device

검색결과 2,861건 처리시간 0.033초

An Experimental Study on the Design of Dobby Hook for Repeated Loading Force (반복하중을 받는 Dobby Hook의 설계에 관한 실험적 연구)

  • Kim, Jong-Su;Lee, Gyu-Jeong;Lee, Tae-Se
    • 한국기계연구소 소보
    • /
    • 통권20호
    • /
    • pp.115-118
    • /
    • 1990
  • Hook of Dobby is a important part of shedding device, which must be endured the repeated loading force. In this paper, experiment on various mechanical characteristics; measurement of loading force were carried out, and compared the experimental values with results of Finite Element Method.

  • PDF

A Study on the Manufacturing Processability of Automatic Winding Device for Manufacturing Strand Specimens (스트랜드 시편 제작 장치의 제작 공정성 연구)

  • Cha, Jae Ho;Jang, Jeong Keun;Lee, Bo Mi;Yoon, Sung Ho
    • Composites Research
    • /
    • 제33권5호
    • /
    • pp.315-320
    • /
    • 2020
  • In this study, when strand specimens were manufactured using an automatic winding device to obtain uniform strand specimens, analysis and test were conducted to investigate the effect of thermal expansion of the mandrel on strand specimens. Also, necessity of changing materials and mandrel configuration was checked. According to the results, strand specimen received unintended tension that was created by thermal expansion of the mandrel and this unintended tension depended on the curing temperature and position of specimens. Tensile test was conducted to check that initial tension affected on the performance of carbon fiber tow prepreg. All other conditions were fixed and only the initial tension was controlled at 40 N, 60 N, and 80 N. From the results of analysis and test, neither additional tension and tension deviation due to the thermal expansion of the mandrel and the initial tension difference had a significant effect on tensile test results, because carbon fiber had sufficiently high strength compared with tension. Therefore, it was confirmed that the change of the mandrel material and configuration of the automatic winding device was unnecessary.

A Study on the System for Improving the Safety Device of the Hydrogen Fluoride ISO Tank (AHF ISO Tank의 안전성 향상을 위한 안전장치에 관한 연구)

  • Park, Sang Bae;Lee, Chang Jun
    • Journal of the Korean Institute of Gas
    • /
    • 제24권3호
    • /
    • pp.54-62
    • /
    • 2020
  • Watching the leakage accident of the Gumi Hube Global AHF(Anhydrous fluoric Acid), I experienced how much chemical accidents affect on our society. Since then, many studies have been conducted on chemical accident in many fields. The use department wanted to find improvement plans for the process system and apply them to the field. The safety field wanted to study improvement of safety through the analysis of damage effects and apply them to emergency response to reduce damage effects. In this study, Mechanical safe devices have been applied which can respond quickly to chemical accidents occurring during the charging operation to enhance the safety of the AFH ISO Tank(Anhydrous fluoric Acid International Organization for Standardization Tank). Investigation of similar tanks confirmed that other chlorine tanks with the same working procedure as AHF ISO Tank have a mechanical safety device, EFV(Excess Flow Valve). Applicability and performance for emergency shutdown when EFV is introduced in AHF ISO Tank can be verified by comparing and examining the accident situation of Hube Global Accident and the accident in Ulsan 2018. Comparing accident cases, expected performance and applicability, It is suggested that EFV, a mechanical safety device that can reduce damage from chemical accidents to the tank and handle accidents early, should be introduced to the tank.

A CASE REPORT OF COMPLICATIONS DURING MANDIBULAR TRANSVERSE SYMPHYSIS WIDENING (하악 이부 확장술 시 나타나는 합병증의 치험례)

  • Suh, Chung-Whan;Kang, Kyung-Hwa;Choi, Moon-Gi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권5호
    • /
    • pp.480-488
    • /
    • 2008
  • Orthodontists often treat cases which are difficult to treat with conventional orthodontics. In such cases, it could be treated with surgical procedures with the help of an oral surgeon. Especially, transverse deficiency of the mandible can be corrected by widening the transverse width of mandibular symphysis, using distraction osteogenesis. Transverse widening of mandibular sympysis is known as a safe treatment but still complications could occur during the treatment. We are reporting some complications of cases that mandibular symphysis transverse widening were applied. Some cases showed complications because of the inappropriate osteotomy line. Since straight vertical osteotomy line was inclined to the left, only the left bony segment was likely to expand. According to bio-mechanical considerations, it will be better to perform a step osteotomy, cutting the eccentric area of the alveolar crest and the centric area of the basal symphyseal area. Complications could also occur by the failure of the distraction device. The tooth borne distraction device was attached on the lingual side of the tooth with composite resin. During the distraction period, it was impossible to obtain appropriate distraction speed and rhythm because of frequent fall off of the distraction device. Therefore, distraction device should be attached firmly with orthodontic band or bone screw, etc. Tooth mobility increasement could also occur as a complication. 'Walking teeth phenomenon' was observed during the distraction period, showing severe teeth mobility and pain during mastication. These symptoms fade out during the consolidation period. Since the patient could feel insecure and uncomfortable, it should be notified to the patient before the procedure. Finally, alveolar crestal bone loss could occur. Alveolar crestal bone loss occurred because of lack of distraction device firmness and teeth trauma caused by lower lip biting habit. Therefore, adequate firmness of the distraction device and habit control will be needed.

Electrical Properties of PNN-PMN-PZT ceramics for Rosen Type Transformer Applications (Rosen type 변압기 응용을 위한 PNN-PMN-PZT 세라믹스의 전기적 특성)

  • Joo, H.K.;Kim, I.S.;Song, J.S.;Kim, M.S.;Jeong, S.J.;Lee, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1244-1245
    • /
    • 2008
  • Recently, piezoelectric transformer is applied to wide fields. Multi layer piezoelectric transformer has the advantage of high step up ratio, electromechanical coupling coefficient(Kp) and mechanical quality factor(Qm), but is indicated of peeling-phenomenon of electrode, rising sintering temperature made price of costly electrode. So in this study, it discuss on method for fabrication of rosen type piezoelectric transformers. For the fabrication as rosen type piezoelectric transformers, synthesized the powder using 0.01Pb$(ni_{1/3}Nb_{2/3})O_3$ - 0.08Pb$(Mn_{1/3}Nb_{2/3})O_3$ - 0.91Pb$(Zr_{0506}Ti_{0496})O_3$ (abbreviated as PNN-PMN-PZT) ceramics. The density, microstructure, dielectric and piezoelectric properties as a function of sintering temperature were investigated. The results indicated that the optimized properties of ceramics were obtained at sintering temperature of 1200$^{\circ}C$, showed the value of $d_{33}$=273pC/N, $K_p$=0.60 $Q_m$=1585, ${\varepsilon}_r$=1454, density=7.917$g/cm^3$ and $tan{\delta}$=0.0064.

  • PDF

Developing a smart structure using integrated DDA/ISMP and semi-active variable stiffness device

  • Karami, Kaveh;Nagarajaiah, Satish;Amini, Fereidoun
    • Smart Structures and Systems
    • /
    • 제18권5호
    • /
    • pp.955-982
    • /
    • 2016
  • Recent studies integrating vibration control and structural health monitoring (SHM) use control devices and control algorithms to enable system identification and damage detection. In this study real-time SHM is used to enhance structural vibration control and reduce damage. A newly proposed control algorithm, including integrated real-time SHM and semi-active control strategy, is presented to mitigate both damage and seismic response of the main structure under strong seismic ground motion. The semi-active independently variable stiffness (SAIVS) device is used as semi-active control device in this investigation. The proper stiffness of SAIVS device is obtained using a new developed semi-active control algorithm based on real-time damage tracking of structure by damage detection algorithm based on identified system Markov parameters (DDA/ISMP) method. A three bay five story steel braced frame structure, which is equipped with one SAIVS device at each story, is employed to illustrate the efficiency of the proposed algorithm. The obtained results show that the proposed control algorithm could significantly decrease damage in most parts of the structure. Also, the dynamic response of the structure is effectively reduced by using the proposed control algorithm during four strong earthquakes. In comparison to passive on and off cases, the results demonstrate that the performance of the proposed control algorithm in decreasing both damage and dynamic responses of structure is significantly enhanced than the passive cases. Furthermore, from the energy consumption point of view the maximum and the cumulative control force in the proposed control algorithm is less than the passive-on case, considerably.

Development and Evaluation of Smart Foundation with Heating Devices (발열장치를 이용한 보온 기능성 스마트 파운데이션의 개발 및 평가)

  • Hwang, Young-Mi;Lee, Jeong-Ran
    • Fashion & Textile Research Journal
    • /
    • 제15권2호
    • /
    • pp.231-239
    • /
    • 2013
  • This research developed a smart girdle for adult women in their 20's that has an inserted carbon weaving heater to help with relief from coldness and abdominal disease through the thermal insulation effect. A pocket of powernet fabric was attached to the inside of the girdle for the easy insertion and separation of the heating device, while the heating device was fixed to a mesh material by cotton yarn and was wrapped with elastic lining material to prevent the mechanical devices from being exposed. A set of 3 hooks was attached to the center of the back of the heating device in consideration of convenience and mobility. Whereas the switch was inserted into around the right waistband, and the battery into the inner pocket around the waist, to integrate the heating device with the girdle. The satisfaction and usability of the fabricated smart girdle was verified by having research participants wear it to evaluate the appearance change caused by the device, the inconvenience of wearing/unwearing, mobility, and the satisfactory functionality of the device. As a result, the grand mean was evaluated to be high, with appearance (4.19), mobility (4.17), and functionality (4.51) being higher than 4.00; which indicates that the heat generation function of the smart girdle is effective. It may be said that such collection and analysis of data that reflect users' opinions have value and significance in that they can be grafted onto future research on new technology as well as they contribute to taking a step forward in the rapidly increasing research of smart clothing, with the new-type clothing equipped with new function.

Micromachined DNA Manipulation Device Using Circular Multi-Electrodes (원형 다중전극을 이용한 DNA 조작소자)

  • Moon, Sang-Jun;Yun, Jae-Young;Lee, Seung-S.;Nam, Hong-Kil;Chi, Yeun-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제27권7호
    • /
    • pp.1071-1075
    • /
    • 2003
  • In this paper, we present a DNA manipulation device in the reaction chamber, which consists of a center electrode and circular outer electrodes of a reaction unit. The charged bio-molecules, DNA, are manipulated by the charge of the electrode in reaction unit. Controlling the induced dynamic electric field between the center electrode and the outer electrodes, concentration / repulsion / manipulation of bio-molecules are enabled at a periphery of electrode. Concentration of the fluorescent DNA at the center electrode is observed by applying +2V. Subsequently, applying -2V, the concentrated DNA is repelled rapidly from the center electrode, which makes dispersion completely in 0.5second. Furthermore, repeated applying +1V/-1V every 5 seconds at each outer electrode, we can circulate the DNA. We also investigate a micro-heater and sensor for DNA manipulation and reaction temperature. The coefficient of heat-resistance and heater temperature characteristic is 0.0043 and 100$^{\circ}C$/sec, respectively.

Inspection method of BGA Ball Using 5-step Ring Illumination (5층 링 조명에 의한 BGA 볼의 검사 방법)

  • Kim, Jong Hyeong;Nguyen, Chanh D.Tr.
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제21권12호
    • /
    • pp.1115-1121
    • /
    • 2015
  • Fast inspection of solder ball bumps in ball grid array (BGA) is an important issue in the flip chip bonding technology. Particularly, semiconductor industry has required faster and more accurate inspection of micron-size solder bumps in flip chip bonding, as the density of balls increase dramatically. In this paper, we describe an inspection approach of BGA balls by using 5-step ring illumination device and normalized cross-correlation (NCC) method. The images of BGA ball by the illumination device show unique and distinguishable characteristic contours by their 3-D shapes, which are called as "iso-slope contours". Template images of reference ball samples can be produced artificially by the hybrid reflectance model and 3D data of balls. NCC values between test and template samples are very robust and reliable under well-structured condition. The 200 samples on real wafer are tested and show good practical feasibility of the proposed method.