• Title/Summary/Keyword: mechanical device

Search Result 2,854, Processing Time 0.028 seconds

A Study on Measuring Vehicle Length Using Laser Rangefinder (레이저 거리계를 이용한 차량 전장 측정 방법에 관한 연구)

  • Ryu, In-Hwan;Kwon, Jang-Woo;Lee, Sang-Min
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.1
    • /
    • pp.66-76
    • /
    • 2016
  • Determination of type of a vehicle is being used in various areas such as collecting tolls, collecting statistical traffic data and traffic prognosis. Because most of the vehicle type classification systems depend on vehicle length indirectly or directly, highly reliable automatic vehicle length measurement system is crucial for them. This study makes use of a pencil beam laser rangemeter and devises a mechanical device which rotates the laser rangemeter. The implemented system measures the range between a point and the laser rangemeter then indicates it as a spherical coordinate. We obtain several silhouettes of cross section of the vehicle, the rate of change of the silhouettes, signs of the rates then squares the rates to apply cell averaging constant false alarm rate (CA-CFAR) technique to find out where the border is between the vehicle and the background. Using the border and trigonometry, we calculated the length of the vehicle and confirmed that the calculated vehicle length is about 94% of actual length.

Stress-Strain Responses of Concrete Confined by FRP Composites (FRP 합성재료에 의하여 구속된 콘크리트의 응력-변형률 응답 예측)

  • Cho, Soon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.803-810
    • /
    • 2007
  • An analytical method capable of predicting various stress-strain responses in axially loaded concrete confined with FRP (fiber reinforced polymers) composites in a rational manner is presented. Its underlying idea is that the volumetric expansion due to progressive microcracking in mechanically loaded concrete is an important measure of the extent of damage in the material microstructure, and can be utilized to estimate the load-carrying capacity of concrete by considering the corresponding accumulated damage. Following from this, an elastic modulus expressed as a function of area strain and concrete porosity, the energy-balance equation relating the dilating concrete to the confining device interactively, the varying confining pressure, and an incremental calculation algorithm are included in the solution procedure. The proposed method enables the evaluation of lateral strains consecutively according to the related mechanical model and the energy-balance equation, rather than using an empirically derived equation for Poisson's ratio or dilation rate as in other analytical methods. Several existing analytical methods that can predict the overall response were also examined and discussed, particularly focusing on the way of considering the volumetric expansion. The results predicted by the proposed and Samaan's bilinear equation models correlated with observed results with a reasonable degree, however it can be judged that the latter is not capable of predicting the response of lateral strains correctly due to incorporating the initial Poisson's ratio and the final converged dilation rate only. Further, the proposed method seems to have greater benefits in other applications by the use of the fundamental principles of mechanics.

Measurement of Ir-192 Source Activity for High Dose Rate Brachytherapy (고 선량률 근접치료시 사용되는 Ir-192 선원의 방사능 평가)

  • 최동락;허승재;안용찬;임도훈;김대용;우홍균
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.25-29
    • /
    • 1997
  • Ir-192 source activity for high dose rate brachytherapy is measured using Farmertype ionization chamber. The source-to-chamber distance is 10 cm and the measured charge unit is converted to activity unit. The measured values are compared to the values provided from vendor. Because of time dependency of Ir-192 source activity, the activities are regularly checked and compared to calculated values. As the accuracy of Ir-192 source activity is depend on the mechanical measurement setup, we estimated the precision of remote controlled source dwell position using home-made device and film scanner. The difference between measured and predicted dwell position is within 1 mm. As a result, the errors of source activity are 0.7${\pm}$1.5 % for measured and vendor-provided values and 0.l${\pm}$1.2% for measured and time-dependent calculated vlaues. In conclusion, our measured activity has been comparable to the values provided from vendor and our brachytherapy unit has been very accurate until now. Regular quality control of brachytherapy is essential for successful treatment which depends on the accuracy of source position and activity.

  • PDF

Effect of Corrosion Environment on the Fretting Wear Corrosion of a Hinge Material( I ) (힌지재료의 찰과마멸부식에 미치는 부식환경의 영향( I ))

  • Kwak Nam-In;Lim Uh-Joh;Lee Jong-Rark
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.1 s.9
    • /
    • pp.26-32
    • /
    • 2000
  • The fretting wear corrosion characteristics between the SM20C and the SM20C, the YBsC3 and the STC4H was experimented by using radical type friction experimental device under the corrosion environment of atmosphere, neutral solution, acid solution and chemical factors of the sea water. The affection of underground water that affect fretting wear corrosion of the SM20C which is moving specimen was more sensitive at the STC4H and more insensible at the YBsC3. The affection of underground water that affect fretting wear corrosion of the STC4H was less, but in the $0.5\%\;H_2SO_4$ and $0.5\%\;HNO_3$ solutions the fretting wear corrosion of the STC4H was more large. The fretting wear corrosion of the SM20C which is moving specimen in the underground water was less than in the $3.5\%\;NaCl$, $0.5\%\;H_2SO_4$ and $0.5\%\;HNO_3$ solutions. As time passed, the fretting wear corrosion is increased in the $HNO_3$ solution and dull in the $0.5\%\;H_2SO_4$ solution.

  • PDF

Applications of Nanomanipulator in Nanowires (나노메니퓰레이터를 이용한 나노선의 특성평가)

  • Yoon, Sang-Won;Seo, Jong-Hyun;Ahn, Jae-Pyoung;Seong, Tae-Yeon;Lee, Kon-Bae
    • Journal of Powder Materials
    • /
    • v.16 no.2
    • /
    • pp.138-145
    • /
    • 2009
  • The combination of focused ion beam (FIB) and 4 point probe nanomanipulator could make various nano manufacturing and electrical measurements possible. In this study, we manufactured individual ZnO nanowire devices and measured those electrical properties. In addition, tensile experiments of metallic Au and Pd nanowires was performed by the same directional alignment of two nanomanipulators and a nanowire. It was confirmed from I-V curves that Ohmic contact is formed between electrodes and nanomanipulators, which is able to directly measure the electrical properties of a nanowire itself. In the mechanical tensile test, Au and Pd nanowires showed a totally different fracture behavior except the realignment from <110> to <002>. The deformation until the fracture was governed by twin for Au and by slip for Pd nanowires, respectively. The crystallographic relationship and fracture mechanism was discussed by TEM observations.

Stability Analysis for a Virtual Spring Model with an Extrapolation and High-frequency ZOH (외삽법과 고주파 영차홀드 출력이 포함된 가상 스프링 모델의 안정성 영역 분석)

  • Lee, Kyungno
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.12-17
    • /
    • 2018
  • In order to enhance the realism of a virtual environment, a method of maximizing the stiffness of the virtual environment model is needed, which maintains the stability of the haptic system. In our previous research, we proposed a haptic system with a first order hold, instead of a zero order hold, and showed that the maximum available stiffness of a virtual spring with the first-order hold is larger than that with the zero-order hold. However, in terms of real system implementation, the zero order hold is a more common and easy method. In this paper, we propose an extrapolation method and a high frequency zero-order-hold output method in order to obtain the stability region using a zero order hold, which is equivalent to the method using the first-order-hold. The simulation results shows that the stability range of the virtual spring becomes almost the same as that of the method using the first order hold when the sampling period of the high frequency zero-order-hold method is decreased. Moreover, the stability range of the proposed method is several times to several tens of times greater than that of the method using the zero order hold only. Therefore, it is expected that the proposed method can enhance the realism of rigid bodies in a virtual environment.

5GHz Wi-Fi Design and Analysis for Vehicle Network Utilization (차량용 네트워크 활용을 위한 5GHz WiFi 설계 및 분석)

  • Yu, Hwan-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.18-25
    • /
    • 2020
  • With the development of water internet technology, data communication between objects is expanding. Research related to data communication technology between vehicles that incorporates related technologies into vehicles has been actively conducted. For data communication between mobile terminals, data stability, reliability, and real-time performance must be guaranteed. The 5 GHz Wi-Fi band, which is advantageous in bandwidth, communications speed, and wireless saturation of the wireless network, was selected as the data communications network between vehicles. This study analyzes how to design and implement a 5 GHz Wi-Fi network in a vehicle network. Considering the characteristics of the mobile communication terminal device, a continuous variable communications structure is proposed to enable high-speed data switching. We simplify the access point access procedure to reduce the latency between wireless terminals. By limiting the Transmission Control Protocol Internet Protocol (TCP/IP)-based Dynamic Host Configuration Protocol (DHCP) server function and implementing it in a broadcast transmission protocol method, communication delay between terminal devices is improved. Compared to the general commercial Wi-Fi communication method, the connection operation and response speed have been improved by five seconds or more. Utilizing this method can be applied to various types of event data communication between vehicles. It can also be extended to wireless data-based intelligent road networks and systems for autonomous driving.

Annual report of thoracic and cardiovascular surgery in Korea [II] (흉부외과 진료통계( II ) -1992년-)

  • Sun, Kyung;Kwak, Young-Tae;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 1993
  • This is the result of the annual statistic analysis of thoracic and cardiovascular surgical cases in 1992 Korea. Overall 17, 520 cases of surgery [11, 732 cases of thoracic surgery by 54 institutes / 5, 788 cases of cardiovascular surgery by 48 institutes] were done. 1. Tumor [N=2, 532] : Lung was the most frequently involved organ by tumor [54.9%],and the remainders were mediastinum [16.2%] / esophagus [14.8%] / chest wall [11.7%] / tracheobronchus [1.3%] / pleura [1.1%] in order. Of 1, 082 cases of primary lung cancer surgery,the frequency of cell type was squamous [62.6%] / adeno [21.6%] / small cell [7.1%] / large cell [2.7%]. Of 411 cases of mediastinal tumor surgery,the frequency of cell type was neurogenic [28.8%] / thymoma [27.6%] / teratoma [17.7%] / congenital cystic [17.2%]. Of 376 cases of esophageal tumor surgery,primary cancer were the most [85.4%]. 2. Infection [N=3, 157] : Pleura was the most frequently involved organ [59.0%],and the remainders were lung [31.3%] / chest wall [8.6%] / mediastinum [1.1%] in order. 3. Miscellaneous [N=6, 043] : Lung and pleural disease esp. pneumothorax [85.1%] was the most frequent surgical indication. The remainders were chest wall anomaly [3.4%] / benign esophageal disease [3.4%] / diaphragmatic pathology [2.4%] / myasthenia [1.4%] in order. Of 85 cases of thymectomy for myasthenia gravis,thymoma was noted in 58.8%. 1. Congenital heart disease [N=3, 363] : The ratio of noncyanotic to cyanotic heart disease was 3:1. Of 2, 516 cases of noncyanotic heart disease,the frequency of disease entity was VSD [44.1%] / ASD [26.0%] / PDA [19.4%] / PS [3.3%],and that of 847 cases of cyanotic heart disease was TOF [29.4%] / ECD [15.6%] / TGA [9.7%] / DORV [7.6%]. Overall mortalities were 2.1% in noncyanotic and 12.2% in cyanotic heart surgery. 2. Acquired heart disease [N=1, 929] : Of 1, 422 cases of valvular surgery,single mitral pathology was the most frequent candidate [48.0%],and total 1, 574 prosthetic valves which were mainly mechanical [95.6%] were used. Of 376 cases of coronary surgery,triple vessel was the most [35.9%],and the frequency of bypassing grafts was great saphenous vein [52.9%] / internal mammary artery [44.7%] / artificial vessel [2.4%]. Overall mortalities were 3.4% in valvular and 4.5% in coronary surgery. 3. Pericardium,Cardiac tumor,Arrhythmia,Aortic aneurysm,Assist device,and Pacemaker : There were no specific changes compared to previous survey1]. This nation-wide inquiry will be continued and reported annually by KTCS Society.

  • PDF

A Study of the Relationship between Perception and Activities in the News Replies -Focused on News Perception and Credibilities- (온라인 댓글 인식과 댓글 활동의 관계에 관한 연구 -댓글의 신뢰도와 인터넷뉴스 수용자의 수용경향 중심으로-)

  • Kweon, Sang-Hee;Kim, Ik-Hyun
    • Korean journal of communication and information
    • /
    • v.42
    • /
    • pp.44-78
    • /
    • 2008
  • The present study explored the agenda setting effects of replies called "Daet-Gul", and perception of the news replies. This study has established three research questions: 1) the recognition of the online communication 2) the degree of the reading and writing on online spare 3) the amount of the effects on the online communication. This study is performed using survey method. The survey results indicated in that the participants are very passive readers and writers on the online spare. In addition, the survey repliers evaluated that replies' mechanical device and antigravitational speed have high score, whereas they marked low store in the content and credibility of 'the replies. Therefore, they did not estimate the effects of the replies highly. All the results indicate that 'the replies' is not the fundamental factors of the deliberative democracy. It's because online communication with 'the replies' are thought to be fated the abuse and slander. Therefore, it's essential to improve the online communication with 'the replies', through the introduction of the 'trackback', which is a sort of the 'remote replies'

  • PDF

A Study on the Electrical Resistivity of Graphene Added Carbon Black Composite Electrode with Tensile Strain (인장변형에 따른 그래핀복합 카본블랙전극의 저항변화연구)

  • Lee, T.W.;Lee, H.S.;Park, H.H.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.1
    • /
    • pp.55-61
    • /
    • 2015
  • Stretchable electrode materials are focused to apply to flexible device such as e-skin and wearable computer. Used as a flexible electrode, increase in electrical resistance should be minimalized under physical strain as bend, stretch and twist. Carbon black is one of candidates, for it has many advantages of low cost, simple processing, and especially reduction in resistivity with stretching. However electrical conductivity of carbon black is relatively low to be used for electrodes. Instead graphene is one of the promising electronic materials which have great electrical conductivity and flexibility. So it is expected that graphene added carbon black may be proper to be used for stretchable electrode. In this study, under stretching electrical property of graphene added carbon black composite electrode was investigated. Mechanical stretching induced cracks in electrode which means breakage of conductive path. However stretching induced aligned graphene enhanced connectivity of carbon fillers and maintained conductive network. Above all, electronic structure of carbon electrode was changed to conduct electrons effectively under stretching by adding graphene. In conclusion, an addition of graphene gives potential of carbon black composite as a stretchable electrode.