• 제목/요약/키워드: mechanical anchor

검색결과 84건 처리시간 0.028초

원전 구조물용 대구경 철근의 기계적 정착을 위한 정착판 설계 (Anchor plate design for mechanical anchorage of large diameter reinforcement in nuclear containment buildings)

  • 이성호;천성철;오보환;박형철;나환선;김상구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.136-139
    • /
    • 2003
  • The re-bar work in the construction of nuclear power plants is difficult, due to the large diameter and the congestion of reinforcements. The mechanical anchorage offers a potential solution for this problem. However, the requirements or the standards for the shape of anchor plate of mechanical anchor has not been clearly established up to now. In this paper, the required performance of the mechanical anchorage for large diameter reinforcements in nuclear power plants are proposed, and the anchor plates are designed through nonlinear finite element analysis. The diameters of anchor plate are determined to be $\sqrt{5}$ times of reinforcement diameter for longitudinal reinforcements and $\sqrt{10}$ for shear reinforcements. The thickness of anchor plates is optimized as 0.3-0.35 times of reinforcement diameter for longitudinal reinforcements and 0.5~0.56 times for shear reinforcements.

  • PDF

Numerical Simulation of Electro-Mechanical Impedance Response in Cable-Anchor Connection Interlace

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • 비파괴검사학회지
    • /
    • 제31권1호
    • /
    • pp.11-23
    • /
    • 2011
  • In this study, a finite element(FE) analysis on electro-mechanical impedance response of cable-anchor connection interface under various anchor force is presented. In order to achieve the objective, the following approaches are implemented. Firstly, an interface washer coupled with piezoelectric(PZT) material is designed for monitoring cable-force loss. The interface washer is a small aluminum plate on which a PZT patch is surface-bonded. Cable-force loss could be monitored by installing the interface washer between the anchor plate and the anchorage of cable-anchor connection and examining the changes of impedance of the interface washer. Secondly, a FE model for cable-anchor connection is established to examine the effect of cable-force on impedance response of interface washer. Also, the effects of geometrical and material properties of the interface washer on impedance responses under various cable-forces are investigated. Finally, validation of the FE analysis is experimentally evaluated by a lab-scale cable-anchor connection.

철근 기계적 정착장치의 설계 고려사항과 인발특성 (Design Considerations and Pull-Out Behavior of Mechanical Anchor of Reinforcement)

  • 천성철;김대영
    • 콘크리트학회논문집
    • /
    • 제13권6호
    • /
    • pp.593-601
    • /
    • 2001
  • 철근콘크리트구조에서 철근의 인장력이 발휘되기 위해서는 적절한 정착길이 또는 갈고리가 필요하다. 그런데, 접합부와 같이 배근이 집중되는 곳이나 대구경 고강도철근이 필요한 경우 정착을 위한 정착길이나 갈고리의 제작 및 배근작업이 어려우며 콘크리트의 충진성도 저하될 수 있다. 또한 갈고리부분의 과도한 응력집중으로 국부적인 지압파괴나 slip이 발생될 우려도 있다. 이러한 문제점을 해결할 수 있는 방안으로 정착판을 철근 단부에 부착한 기계적 정착공법이 제안되고 있다. 본 연구는 기계적 정착공법의 기초가 되는 정착장치의 요구성능과 정착설계법을 고찰하고 인발실험를 통해 정착장치의 앵커기능을 확인하고자 한다 인발실험 결과, 본 연구에서 설계된 정착장치는 앵커로써의 기능을 적절히 발휘하여 기존 CCD 이론식과 매우 근접한 내력을 발휘하였다 철근항복내력 이상의 정착내력을 지니는 경우, 항복하중까지 콘크리트에 아무런 손상이 발생되지 않았으며, 정착판 후미에서 콘크리트와의 상대변위는 0.2mm이하로 콘크리트에 손상을 유발시키지 않을 것으로 판단되었다. 따라서, 본 연구의 설계과정으로 제작된 기계적 정착장치를 통해 콘크리트에 유해한 손상 없이 필요한 정착내력을 확보할 수 있다. 그러나, 철근간 간격이 좁아 파괴면이 중첩되는 경우에는 정착내력이 크게 저하되어, 순수한 콘크리트 내력만으로 기계적 정착설계가 이루어지는 경우 상당한 매립깊이가 요구된다. 따라서, 실제 구조물의 정착설계를 위해서는 인접부재와의 골조거동(frame action)에 따른 구속효과와 전단보강근의 영향을 고려할 필요가 있다. 이에 대한 추가적인 연구가 필요하다.

선단압축형(JR-2000) 앵커의 인발시험에 관한 특성연구 (Characteristics Study by Pullout Test of Compression(JR-2000) Anchor)

  • 오명주;박태영;하욱재;김문규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.819-824
    • /
    • 2005
  • Anchor system is widely used in construction works to support retaining structures. The compression anchor is characterized by excellent mechanism of pullout resistance, as well as less probability of progressive failure than a tension anchor. This paper presents the mechanical characteristics of a newly developed compression anchor(JR-2000). Field tests were performed to investigate characteristics of the pullout resistance of compression anchor.

  • PDF

Study on grout-free smart ground anchor using electromagnetic induction

  • Hyun-Seok Lee;Jong-Kyu Park;Jung-Tae Kim
    • Structural Engineering and Mechanics
    • /
    • 제90권6호
    • /
    • pp.531-542
    • /
    • 2024
  • This study proposes a ground anchor using electromagnetic induction and utilizes an extended structure using hinges and links and mounting and sensing using electromagnets. The aim is to secure the anchor force, excluding grout, and to secure various sensing capabilities, including ground behavior. We propose a design based on the drilling diameter of 150 mm, and the materials used were STS304 and Aluminum 6061-T6. Computerized analysis was performed to confirm structural safety and functional implementation. The pull-out experiment was conducted by simulating the bedrock environment on a model earthwork as an experiment to check whether anchor force was generated by the insertion and tension of the anchor. The environmental pollution of grout, the difficulty of removing strands, and the inability to check whether the anchor is seated, which were pointed out as disadvantages of the existing ground anchor, were solved. Therefore, this study suggest that it can be effectively utilized as a secure and monitored anchoring solution in eco-friendly construction practices, including the installation of landslide prevention barriers.

코너프로텍션과 내조를 고려한 대용량 LNG 저장탱크 앵커스트랩의 구조설계를 위한 유한요소해석 (Structural Analysis for Design of Anchor Straps for a Large-Scale LNG Storage Tank with Corner Protection and Inner Tank)

  • 김성주;하성규;김성종;이영환
    • 대한기계학회논문집A
    • /
    • 제35권12호
    • /
    • pp.1543-1548
    • /
    • 2011
  • 본 연구에서는 대용량 액화천연가스(LNG 즉 Liquefied Natural Gas) 저장탱크의 앵커스트랩(anchor strap)의 설계를 위한 구조해석이 수행되었다. 본 논문에 고려된 LNG 저장탱크는 반경이 40m 의 완전방호식 저장탱크로 크게 외조와 내조로 구성되고, 둘 사이의 공간은 단열재인 블랑켓과 펄라이트로 채워져있다. 앵커스트랩은 내조, 외조 및 코너프로텍션과 연결되어 있어 지진하중에 의한 내조의 파손을 방지하는 역할을 한다. 본 연구에서는 앵커스트랩만 고려한 단일모델과 실제 형상을 고려하여 앵커스트랩, 내조, 외조 및 코너프로텍션을 동시에 고려한 확장모델에 대해서 각각 유한요소해석을 수행하여 비교, 분석하였다. 하중조건으로는 LNG 의 유출상태 및 지진하중을 고려한 다섯 가지 경우를 고려하였고, 각 하중조건에 대한 두 모델의 Tresca 응력분포를 구하여 설계기준과 비교해 보았다.

Anchor bracket 체결 볼트에 대한 절단 강도 해석 (Breaking Strength Analysis for Bolt Connection of Anchor Bracket)

  • 이봉주;양헌석;오형식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.55-60
    • /
    • 2011
  • For the bolster type bogie, bolster anchor body connections are proviede to transmit the longitudinal loads for traction or braking between the carbody and the truck. The bolster anchor body connection is generally composed of anchor rod bracket, anchor rod and its fastening devices. The bolster anchor body connection shall be basically capable of withstanding a longitudinal load resulting from excessive braking case or impact. Additionally the north America standard requires that the anchor rod bracket shall be frangible, I.e. the anchor rod bracket shall fail and fall away under load before the carbody structure is damaged since to protect the cabody structure in the event of unexpected accident. This paper describes the shear connection design using the optimized mechanical fasteners in the bolster anchor body connection to satisfy these Northe America requirements.

  • PDF

이산와법에 의한 원호형 Sea Anchor의 유동장 수치해석 (Numerical Analysis for Flowfield of a Circular Arc Type Sea Anchor by Discrete Vortex Method)

  • 노기덕;권병국;안희춘
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1041-1051
    • /
    • 1998
  • The fluid dynamic properties of a circular arc type sea anchor were calculated by a discrete vortex method. The flow for the surface of the sea anchor was represented by arranging bound vortices at adequate intervals. The simulations were performed by assuming that the separations occur at edges. With time, the drag coefficient was almost constant but the lift coefficient oscillated in a cycle by von Karman's vortex street. As the camber ratios increase, the drag coefficient and Strouhal number were almost constant but the oscillating amplitude of the lift coefficient increased largely.

Numerical Calculation of Flow Pattern and Fluid Force on a Circular Arc-type Sea Anchor

  • Ro, Ki-Deok;Oh, Se-Kyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권8호
    • /
    • pp.1258-1269
    • /
    • 2004
  • The fluid dynamic characteristics of a circular arc type sea anchor were calculated by a discrete vortex method. The flow for the surface of the sea anchor was represented by arranging bound vortices at adequate intervals. The simulations were performed by assuming that the separations occur at edges. With time, the drag coefficient was almost constant but the lift coefficient oscillated in a cycle due to von Karman's vortex street. As the camber ratios increase, the drag coefficient and Strouhal number were almost constant but the oscillating amplitude of the lift coefficient increased largely.

기계적 정착된 철근의 인발거동에 대한 비선형 유한요소 해석 (Nonlinear finite element analysis on the pullout behavior of the mechanical anchorage of reinforcement in concrete)

  • 천성철;이성호;오보환;박형철;나환선;김상구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.132-135
    • /
    • 2003
  • Mechanical anchorage can substitute a standard hook. To enhance the workability and economical benefit of mechanical anchorage, the size of anchor plate should be optimized. In this paper, the pull-out behaviors such as strength, failure mode, and crack patterns of mechanically anchored reinforcement in concrete are investigated using nonlinear finite element analysis. The nonlinear finite element analysis results are consistent with the experimental results. These results show that the optimal anchor plates can be designed using the nonlinear finite element analysis.

  • PDF