• Title/Summary/Keyword: measuring volume

Search Result 798, Processing Time 0.04 seconds

A Study on Surface Properties of Ablative Materials from 0.4MW Arc-Heated Wind Tunnel Test (0.4MW 아크 가열 풍동 시험을 통한 삭마 재료의 표면 특성 연구)

  • Kim, Nam Jo;Oh, Philyong;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.12
    • /
    • pp.1048-1053
    • /
    • 2015
  • Ablative materials in a thermal protection system for atmospheric re-entry suffers from the most severe heat fluxes and temperatures, which induces surface recession in the thickness direction. In this paper, a 0.4MW arc-heated wind tunnel is operated to test for ablative materials, and a non-contact three-dimensional surface measuring system is used to evaluate the different surface characteristics of them. In particular, by postprocessing the three-dimensional image data, the surface roughness and recession of ablative materials can be calculated before and after the wind tunnel test. Moreover, the surface properties are analyzed quantitatively by comparing volume and mass losses of the test specimens.

Perturbation of Dose Distributions for Air Cavities in Tissue by High Energy Electron (고(高) 에너지 전자선(電子線) 치료시(治療時) 체내(體內) 공동(空洞)으로 인(因)한 선량분포(線量分布)의 변동(變動))

  • Chu, S.S.;Lee, D.H.;Choi, B.S.
    • Journal of Radiation Protection and Research
    • /
    • v.1 no.1
    • /
    • pp.22-30
    • /
    • 1976
  • The perturbation of dose distribution adjacent to cavities in high energy electron has shown that the percentage of dose increase varies markedly as a function of the build-up layer, the length and thickness of the cavities, and the electron energy. The dose distribution showed that cavities similar in size to those encountered in the head and neck measured by industrial film dosimetry and corrected by ionization chambers. The most increased doses by measuring are resulted in a localized dose of up to 130% of that measured at the depth of maximum dose within a homogeneous tissue equivalent phantom. The measured values and correction factors of dose perturbation due to air cavities showed in diagrams and would be summarized as follows. 1. In $8{\sim}12MeV$ electron beams, the most marked dose is observed when the build-up layer thickness is 0.5cm and cavity volume is $2{\times}2{\times}2cm^3$. 2. The highest dose point is located under cavity when the energy is increased and cavity length is longer. 3. The cavity length at which the maximum percentage dose occurs decreases with increasing energy. 4. The highest percentage cavity doses are obtained when the energy is high, the build-up layer is thin, the thickness of the cavity is large, and the length of the cavity is approximately 1 to 3cm. 5. The doses of upper portion of cavity are less than the standard dose distribution as 5 to 10%. 6. The maximum range of electron beam are extended as much as thickness of cavity. 7. A cavity having a length of 5cm closely approximates a cavity of infinite length.

  • PDF

The Investigation Study of Compaction Density by Waste Composition Change in Landfill Site (매립장의 반입쓰레기 성상변화에 따른 다짐밀도 조사연구)

  • Jung, Byung-Gil;Choi, Young-Ik;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.397-403
    • /
    • 2008
  • The purpose of this study is to investigate weighted compaction density according to a leading density in truck, a compaction density of solid waste and composition ratios of solid waste fur calculation of a capacity of the landfill sites. The experiments for calculations of in-place density at landfill site have been conducted in S landfill site at B City. The size of vessel for measuring the compaction density was $1m^3(1m{\times}1m{\times}1m)$. The experiment tests have been carried out methods (1 time for bulldozer and 4 times for compactor) that do contain all of specification at the landfill site. Average of the loading density at the landfill site was $0.264\;ton/m^3$ ($0.113{\sim}0.487\;ton/m^3$). When the loading density for each compositions was compared, the composition of the highest average loading density ($0.474\;ton/m^3$) was miscellaneous wastes. The composition of the lowest average loading density ($0.120 ton/m^3$) was general solid waste. The reported results indicated that the compaction density at the landfill site was $0.538\;ton/m^3$, which was calculated with weighted incoming ratios of compositions. The ranges of the density for each composition were from $0.021\;ton/m^3$ to $0.221\;ton/m^3$. When the compaction density for each composition was compared, the composition with the highest average compaction density ($0.221\;ton/m^3$) was miscellaneous wastes. The composition with the lowest average compaction density ($0.021\;ton/m^3$) was general solid wastes.

A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain

  • Jung, Yu-Seok;Lee, Jae-Whang;Choi, Yeon-Jo;Ahn, Jin-Soo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.111-115
    • /
    • 2010
  • PURPOSE. This study was conducted to evaluate clinical validity of a zirconia full-coverage crown by comparing zirconia's wear capacity over antagonistic teeth with that of feldspathic dental porcelain. MATERIALS AND METHODS. The subject groups were divided into three groups: the polished feldspathic dental porcelain group (Group 1), the polished zirconia group (Group 2), and the polished zirconia with glazing group (Group 3). Twenty specimens were prepared from each group. Each procedure such as plasticity, condensation, and glazing was conducted according to the manufacturer's manual. A wear test was conducted with 240,000 chewing cycles using a dual-axis chewing simulator. The degree of wear of the antagonistic teeth was calculated by measuring the volume loss using a three-dimensional profiling system and ANSUR 3D software. The statistical significance of the measured degree of wear was tested with a significant level of 5% using one-way ANOVA and the Tukey test. RESULTS. The degrees of wear of the antagonistic teeth were $0.119{\pm}0.059\;mm^3$ in Group 1, $0.078{\pm}0.063\;mm^3$ in Group 3, and $0.031{\pm}0.033\;mm^3$ in Group 2. Statistical significance was found between Group 1 and Groups 2 and between Group 2 and 3, whereas no statistical significance was found between Group 1 and Group 3. CONCLUSION. Despite the limitations of this study on the evaluation of antagonistic teeth wear, the degree of antagonistic tooth wear was less in zirconia than feldspathic dental porcelain, representing that the zirconia may be more beneficial in terms of antagonistic tooth wear.

Analysis of Middle School Students' Ability in Estimating Order of Magnitude for physical Quantities (중학생의 물리량에 대한 차수 어림 능력 분석)

  • Suh, Jung-Ah;Jo, Kwang-Hee;Pak, Sung-Jae
    • Journal of The Korean Association For Science Education
    • /
    • v.23 no.3
    • /
    • pp.229-238
    • /
    • 2003
  • In this study, we investigated middle school student' ability in estimating order of magnitude of physical quantities. Participants were 448 students of seventh grades and ninth graders in Seoul area. A multiple-choice typed questionnaire was designed for estimating five physical quantities such as length, mass, speed, volume, and density. The answers were analyzed through dimension of quantity, size of object, students' grade and their gender. In the results, more than two thirds of all participants chose the right order of magnitude in estimating length, but only around a quarter of them did so in estimating density. They had a tendency to show lower ability when they estimated order of magnitude of more complex dimensioned quantity. Moreover, students' answers had relatively wide distribution in estimating smaller sized objects. Through there was no big difference between seventh graders and ninth graders in estimation, male students where better in estimating base quantities, especially in length. However, more than half of participants did not choose the right order of magnitude in total and it showed their lack of qualitative understanding about these physical quantities and meaningless usage of unit in measuring.

Basic Research of Non-Invasive Optical Transcutaneous pCo2 Gas Sensor & Analytic Equipment (비침습적 방법에 의한 광학식 Transcutaneous pCo2 가스센서 및 분석장치 개발을 위한 기초연구)

  • Kim, Do-Eok;Lee, Seung-Ha;Cho, Eun-Jong;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.258-263
    • /
    • 2004
  • In this study, we carried out a basic study for the development of optical transcutaneous $pCO_{2}$ gas sensor and analyzer using non-invasive method. The basic principle of $pCO_{2}$ measurement is adapted Beer lambert's law and embodied the system using NDIR method. This measuring system was composed of a IR lamp, a optical filter, a optical reaction chamber, pyroelectric sensor and a signal process. We measured $EtCO_{2}'s$ concentration in basis step instead of $pCO_{2}$ gas that can collect by inflicting heat in outer skin. We minimize the size of optical reaction chamber which takes up the largest volume, to make the portable sensor. We made optical reaction chamber in Si wafer using MEMS technology and the optical reaction chamber was shortened to 2 mm and we carried out an experiment. When we injected the $EtCO_{2}$ to the inside of the optical reaction chamber, we could confirm change of 4.6 mV. The system response time was within 2 second that is fairly fast.

Quantitative Determination and Antioxidant Effects of Cheonwangbosimdan (LC-MS/MS를 이용한 천왕보심단(天王補心丹)의 함량분석 및 항산화 효능 연구)

  • Seo, Chang-Seob;Kim, Ohn Soon;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.45 no.4
    • /
    • pp.300-314
    • /
    • 2014
  • An ultra-performance liquid chromatography-electrospray ionization-mass spectrometer (UPLC-ESI-MS) method was established for the simultaneous quantification of eighteen marker compounds in traditional Korean formula, Cheonwangbosimdan (CWBSD). In addition, we evaluated the antioxidant effects of CWBSD. Eighteen marker components were separated on a UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}m$) and kept at $45^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as mobile phase. The flow rate was 0.3 mL/min and the injection volume was $2.0{\mu}L$. The antioxidant activities of CWBSD were assessed by measuring free radical scavenging activities on 2,2'-azinobis-3-ethylbenzothiazoline-6-sulfonic acid (ABTS) and 1-1-diphenyl-2-picrylhydrazyl (DPPH). The calibration curves of all analytes showed good linearity (correlation coefficient ${\geq}0.9937$) within the test ranges. The limits of detection and quantification for the 18 marker compounds were 0.01-4.71 ng/mL and 0.03-14.13 ng/mL, respectively. The contents of the 18 compounds in CWBSD extract ranged from none to $1701.00{\mu}g/g$. The CWBSD showed the radical scavenging activity in a dose-dependent manner. The concentration required for 50% reduction ($RC_{50}$) against ABTS and DPPH radicals were $149.42{\mu}g/mL$ and $339.24{\mu}g/mL$.

Slope Stability Analysis by Optimization Technique Considering Unsaturated Characteristics of Weathered Granite Soil (화강풍화토 지반의 불포화 특성을 고려한 최적화기법에 의한 사면안정해석 방법)

  • 이승래;이성진;변위용;장범수
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.123-133
    • /
    • 2001
  • Since most of soil slopes are in an unsaturated state, it is necessary to consider the unsaturated characteristics of soil slopes, in order to obtain more reasonable results. Therefore in this study we supplemented a slope stability analysis program to consider them, based on the concept of limit equilibrium. We also applied an optimization technique to search for a failure surface. Besides, we carried out experiments to obtain the unsaturated soil properties required in the analysis with weathered granite soils. We formulated a nonlinear apparent cohesion relationship with the matrix suction to be able to apply the unsaturated shear strength characteristics to the stability analysis. In addition, we intended to obtain more accurate soil water characteristic curves(SWCC) by measuring the change in volume of the specimen in the SWCC tests. As a result, we could appropriately assess the change of the safety factor according to the rainfall intensity and duration, by considering the variation of suction, permeability, and shear strength caused by the infiltration of rainfall into slopes.

  • PDF

Shear Deformation of Steel Fiber-Reinforced Prestressed Concrete Beams

  • Hwang, Jin-Ha;Lee, Deuck Hang;Ju, Hyunjin;Kim, Kang Su;Kang, Thomas H.K.;Pan, Zuanfeng
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.sup3
    • /
    • pp.53-63
    • /
    • 2016
  • Steel fiber-reinforced prestressed concrete (SFRPSC) members typically have high shear strength and deformation capability, compared to conventional prestressed concrete (PSC) members, due to the resistance provided by steel fibers at the crack surface after the onset of diagonal cracking. In this study, shear tests were conducted on the SFRPSC members with the test variables of concrete compressive strength, fiber volume fraction, and prestressing force level. Their localized behavior around the critical shear cracks was measured by a non-contact image-based displacement measurement system, and thus their shear deformation was thoroughly investigated. The tested SFRPSC members showed higher shear strengths as the concrete compressive strength or the level of prestress increased, and their stiffnesses did not change significantly, even after diagonal cracking due to the resistance of steel fibers. As the level of prestress increased, the shear deformation was contributed by the crack opening displacement more than the slip displacement. In addition, the local displacements around the shear crack progressed toward directions that differ from those expected by the principal strain angles that can be typically obtained from the average strains of the concrete element. Thus, this localized deformation characteristics around the shear cracks should be considered when measuring the local deformation of concrete elements near discrete cracks or when calculating the local stresses.

Analysis of Risk Factors and Management of Cerebrospinal Fluid Morbidity in the Treatment of Spinal Dysraphism

  • Lee, Byung-Jou;Sohn, Moon-Jun;Han, Seong-Rok;Choi, Chan-Young;Lee, Dong-Joon;Kang, Jae Heon
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.225-231
    • /
    • 2013
  • Objective : Spinal dysraphism defects span wide spectrum. Wound dehiscence is a common postoperative complication, and is a challenge in the current management of cerebrospinal fluid (CSF) leaks and wound healing. The purpose of this study is to evaluate the risks of CSF-related morbidity in the surgical treatment of spinal dysraphism. Methods : Ten patients with spinal dysraphism were included in this retrospective study. The median age of the cohort was 4.8 months. To assess the risk of CSF morbidity, we measured the skin lesion area and the percentage of the skin lesion area relative to the back surface for each patient. We then analyzed the relationship between morbidity and the measured skin lesion area or related factors. Results : The overall median skin lesion area was 36.2 $cm^2$ (n=10). The percentage of the skin lesion area relative to the back surface ranged from 0.6% to 18.1%. During surgical reconstruction, 4 patients required subsequent operations to repair CSF morbidity. The comparison of the mean area of skin lesions between the CSF morbidity group and the non-CSF morbidity group was statistically significant (average volume skin lesion of $64.4{\pm}32.5cm^2$ versus $27.7{\pm}27.8cm^2$, p<0.05). CSF morbidity tended to occur either when the skin lesion area was up to 44.2 $cm^2$ or there was preexisting fibrosis before revision with an accompanying broad-based dural defect. Conclusion : Measuring the lesion area, including the skin, dura, and related surgical parameters, offers useful information for predicting wound challenges and selecting appropriate reconstructive surgery methods.