• Title/Summary/Keyword: measuring volume

Search Result 793, Processing Time 0.033 seconds

Preparation of Activated Carbon from Wasted Food by Chemical Activation with Zinc Chloride (염화아연 약품활성화를 이용한 음식물쓰레기로부터 활성탄 제조)

  • Kang, Hwa-Young;Lee, Young-Dong;Kim, Se-Hoon;Park, Sung-Bong;Jung, Jae-Sung;Park, Sang-Sook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.900-906
    • /
    • 2008
  • It was studied to utilize wasted food as a starting material to produce for activated carbon. The wasted food was chemically activated with zinc chloride. Experiments were carried out at different chemical ratios(activating agent/wasted foods), activation temperatures, and activation time. The activated products were characterized by measuring the iodine and methylene blue number, the BET surface area, the pore volume, the micropore ratio, the pore diameter, the yields and the scanning electron microscope(SEM). For the products activated by impregnation ratio of 1.0 of ZnCl$_2$ at 500$^{\circ}C$ for 60 min in a rotary kiln reactor had iodine number of 480 mg/g, methylene blue number of 95 mL/g, BET surface area of 410 m$^2$/g, pore volume of 0.248 cm$^3$/g, and average pore diameter of 2.43 nm, respectively. The activated carbon obtained had the contribution of micropore area of 70.7% to the total pore area and micropore volume of 53.2% to the total pore volume.

Effects of Forage Feeding Levels on the Udder Volume, Serum Hormone Level and Lactation Characteristics in Dairy Cows: From Growing to Lactating Phase (Holstein 젖소에서 조사료 급여 수준이 유방크기, 호르몬 및 산유특성에 미치는 영향: 육성기부터 비유기까지)

  • Lee, Byung-Woo;Sugathan, Subi;Singh, Naresh Kumar;Yoon, Sei-Hyung;Yoon, Byung-Il
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.33 no.4
    • /
    • pp.319-326
    • /
    • 2013
  • In the present study, we investigated the effects of high forage diets on the volume of udder, hormone level in blood, and lactation characteristics in the Holstein dairy cow. We divided into two groups; high forage diet [HF, concentrate: forage=4:6 n=41] and low forage diet [LF, 6:4 n=21]. Five cows were selected from each group based on their age for measuring the udder volume and the serum levels of estradiol and progesterone. Lactation characteristics were compared between HF and LF. The udder volume was 2.5 fold larger in HF at early gestation (p<0.01), but no difference was noted afterward. For the hormone levels, no significant difference was found between the groups. In HF, milk yield was significantly increased and maintained high longer, while somatic cell count was approximately 50% lower. Meanwhile, the milk fat content was significantly lower in HF during early lactating phase (p<0.001), but there was no difference thereafter. For milk protein and solid content, and MUN, no differences were found between the groups during lactation. Our results indicated that feeding high forage diets to dairy cows can increase milk yield and quality without notable changes in the udder volume and hormone level.

Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI

  • Chen Cui;Gang Yin;Minjie Lu;Xiuyu Chen;Sainan Cheng;Lu Li;Weipeng Yan;Yanyan Song;Sanjay Prasad;Yan Zhang;Shihua Zhao
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.114-125
    • /
    • 2019
  • Objective: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. Materials and Methods: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. Results: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). Conclusion: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia.

A Turbidimetric Determination of Protein by Trichloroacetic Acid

  • Choi, Wahn-Soo;Chung, Kae-Jong;Chang, Man-Sik;Chun, Jae-Kwang;Lee, Hyang-Woo;Hong, Sung-Youl
    • Archives of Pharmacal Research
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 1993
  • Based on the turbidimetric response of protein with 50% trichloroacetic acid (TCA), this study aims to introduce an assay method for protein in solution. The standard procedure consists of mixing equal volume of sample solution (standard or unknown) with 50%-TCA solution and measuring the absorbance at 450 nm after 20 min. The absorbances of the solutions were almost stable over 120 min at room temperature. This assy method is simple, reproducible, and tolerant to many interfering substances. It can detect less amount than $10\mu$g/ml of bovin serum albumin. The assay method has low protein-to-protein variability over wide range of molecular weight.

  • PDF

The effect on the components variation of syngas by changing temperature and steam addition in biomass gasification process (바이오매스 가스화 과정에서의 온도와 가습의 변화가 전환가스 조성에 미치는 영향)

  • Ahn, Seong-Yool;Choi, Gyung-Min;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3429-3434
    • /
    • 2007
  • An experimental study was carried out to investigate gasification process of wood sawdust in the I-dimensional downdraft fixed bed gasifier. The preheated air was used oxidizer and steam were used as a gasifying agent. The operating parameters, the supplied air temperature and steam were used. The oxidizer temperature was varied from 500K to 620K and vapor was added. The gasification process was monitored by measuring temperature at three position near the biomass using R-type thermocouples and the syngas composition was analyzed by gas chromatograph. The change of hydrogen and carbon monoxide, carbon dioxide, methane was observed. Overall, the volume fraction of hydrogen and methane were increased widely as increasing the oxidizer temperature and adding steam.

  • PDF

Development of a Test Stand for Measuring Ink Jetting Performance (잉크젯 토출 특성 평가 장치 개발)

  • Kwon, Kye-Si
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.45-50
    • /
    • 2008
  • An ink jetting measurement system has been developed such that the velocity as well as the volume of ink droplets can be measured. In order to measure the ink droplet, a strobe LED light was synchronized to the droplet firing signal in order to obtain frozen droplet images. Then, a LabVIEW based software was developed for the analysis of the droplet image. For the efficient droplet analysis, a user generated rectangular shaped ROI (Region of Interest) was used. By using ROI, the ink droplet image can be easily isolated from the other structures such as printhead and the processing area can be minimized.

Comparative Analysis of Photoplethysmography under Pulsed Magnetic Field and Low Level Laser Stimulus: Motivation for Blood Flow Increase using Stimulus on Acupoint LI4 (Hegu)

  • Kim, Young Jin;Yoo, Jun Sang;Hwang, Do Guwn;Lee, Hyun Sook
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.32-36
    • /
    • 2014
  • The purpose of this study was to investigate the effect of pulsed magnetic field (PMF) and low frequency low level laser (LFLLL) stimuli on acupoint LI4 (Hegu) using photoplethysmography (PPG). Our PMF system was designed to generate maximum intensity of 0.20 T at a transition time of 0.16 ms, with pulse intervals of 1 Hz. The diode laser with wavelength of 650 nm and power of 5 mW was also employed. It was observed the change of the pulsating blood volume through measuring PPG signals from both hands. These results imply that stimulating acupoint LI4 with PMF and LFLLL improves the circulation of peripheral vascular system. In particular, PMF stimulation brings a big improvement of the blood flow even with short term stimulation of 3-4 minutes compared to LFLLL stimulus.

Quality Evaluation and Standardization Trend of Holographic Displays (홀로그래픽 디스플레이 화질 평가 및 표준화 연구 동향)

  • Nam, J.;Oh, K.J.;Park, M.;Kim, J.
    • Electronics and Telecommunications Trends
    • /
    • v.32 no.5
    • /
    • pp.65-73
    • /
    • 2017
  • A holography technique optically reconstructs a three-dimensional object in space to provide a natural sense of depth and volume to the observer, thereby providing an ultimate 3D image capable of solving the problem of "vergence-accommodation conflict" occurring in a conventional stereoscopic imaging system. In this paper, we present a technical framework for measuring the performance and evaluating the quality of a holographic display, which enables a quantitative measurement of the optical and physical properties that affect the performance and quality of a holographic display. In addition, we provide the trend regarding standardization related to holographic display measurements. Although this trend has barely started, research activities related to holographic display measurements and quality evaluations are expected to grow in the near future.

Beta particle energy spectra shift due to self-attenuation effects in environmental sources

  • Alton, Thomas Theakston;Monk, Stephen David;Cheneler, David
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1483-1488
    • /
    • 2017
  • In order to predict and control the environmental and health impacts of ionizing radiation in environmental sources such as groundwater, it is necessary to identify the radionuclides present. Beta-emitting radionuclides are frequently identified by measuring their characteristic energy spectra. The present work shows that self-attenuation effects from volume sources result in a geometry-dependent shift in the characteristic spectra, which needs to be taken into account in order to correctly identify the radionuclides present. These effects are shown to be compounded due to the subsequent shift in the photon spectra produced by the detector, in this case an inorganic solid scintillator ($CaF_2:Eu$) monitored using a silicon photomultiplier. Using tritiated water as an environmentally relevant, and notoriously difficult to monitor case study, analytical predictions for the shift in the energy spectra as a function of depth of source have been derived. These predictions have been validated using Geant4 simulations and experimental results measured using bespoke instrumentation.

Effects of metal catalysts on the characteristics of NO sensor using ZnO thin film as sensing material (금속 촉매가 ZnO 박막을 감지물질로 이용한 NO 센서의 특성에 미치는 영향)

  • Chung, Gwiy-Sang;Jeong, Jae-Min
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.58-61
    • /
    • 2010
  • This paper describes the fabrication and characteristics of NO sensor using ZnO thin film by RF magnetron sputter system. The sensitivity, working temperature, and response time of sputtered pure ZnO thin film and added catalysts such as Pt, Pd, Al, Ti on those films were measured and analyzed. The sensitivity of pure ZnO thin film at working temperature of $300^{\circ}C$ is 0.875 in NO gas concentration of 0.046 ppm. At same volume of the gas in chamber, measuring sensitivity of 1.87 at $250^{\circ}C$ was the case of Pt/ZnO thin film. The ZnO thin films added with catalyst materials were showed higher sensitivity, lower working temperature and faster adsorption characteristics to NO gas than pure ZnO thin film.