Browse > Article
http://dx.doi.org/10.4283/JMAG.2014.19.1.032

Comparative Analysis of Photoplethysmography under Pulsed Magnetic Field and Low Level Laser Stimulus: Motivation for Blood Flow Increase using Stimulus on Acupoint LI4 (Hegu)  

Kim, Young Jin (Department of Oriental Biomedical Engineering, Sangji University)
Yoo, Jun Sang (Department of Sasang Constitutional Medicine, Sangji University)
Hwang, Do Guwn (Department of Oriental Biomedical Engineering, Sangji University)
Lee, Hyun Sook (Department of Oriental Biomedical Engineering, Sangji University)
Publication Information
Abstract
The purpose of this study was to investigate the effect of pulsed magnetic field (PMF) and low frequency low level laser (LFLLL) stimuli on acupoint LI4 (Hegu) using photoplethysmography (PPG). Our PMF system was designed to generate maximum intensity of 0.20 T at a transition time of 0.16 ms, with pulse intervals of 1 Hz. The diode laser with wavelength of 650 nm and power of 5 mW was also employed. It was observed the change of the pulsating blood volume through measuring PPG signals from both hands. These results imply that stimulating acupoint LI4 with PMF and LFLLL improves the circulation of peripheral vascular system. In particular, PMF stimulation brings a big improvement of the blood flow even with short term stimulation of 3-4 minutes compared to LFLLL stimulus.
Keywords
pulsed magnetic field stimulus; low level laser stimulus; acupoint LI4; PPG;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Y. Maegawa, T. Itoh, T. Hosokawa, K. Yaegashi, and M. Nishi, Lasers Surg Med. 27, 427 (2000).   DOI
2 N. M. Shupak, F. S. Prato, and A. W. Thomas, Neurosci. Lett. 363, 157 (2004).   DOI   ScienceOn
3 E. Haker, H. Egekvist, and P. Bjerring, J. Auton. Nerv. Syst. 79, 52 (2000).   DOI   ScienceOn
4 J. Walleczek, The FASEB Journal 6, 3177 (1992).
5 J. Hulme, V. Robinson, R. DeBie, G. Wells, M. Judd, and P. Tugwell, Cochrane Database Syst. Rev. 1, 14 (2002).
6 H. S. Lee, S. W. Kim, and D. G. Hwang, IEEE Trans. Magn. 47, 3060 (2011).   DOI   ScienceOn
7 A. S. Chao, A. Chao, T. H. Wang, Y. C. Chang, H. H. Peng, S. D. Chang, and A. M. Wong, Pain 127, 214 (2007).   DOI   ScienceOn
8 D. Hwang, J. Kor. Mag. Soc. 24, 28 (2014).   DOI   ScienceOn
9 R. Babapour, E. Glassberg, and GP Lask, Low-energy laser systems. Clin Dermatol 13, 87 (1995).   DOI   ScienceOn
10 M. Sandberg, Q. Zhang, J. Styf, B. Gerdle, and L. G. Lindberg, Acta. Physiol. Scand. 183, 335 (2005).   DOI   ScienceOn
11 T. Huang, L. J. Yang, W. B. Zhang, S. Y. Jia, Y. Y. Tian, G. J. Wang, X. Mu, L. Wang, and G. Litscher, Evid. Based Complem. and Altern. Med. 2012, 4 (2012).