• Title/Summary/Keyword: measuring instrument

Search Result 844, Processing Time 0.038 seconds

The Development of Visual Inspection for Length Measurement of Injection Product Using Vision System (Vision System을 이용한 사출제품의 길이 측정용 시각검사 System 개발)

  • J.Y. Kim;B.S. Oh;S. You
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.126-134
    • /
    • 1997
  • In this study, We made visual inspection system using Vision Board. It is consist of an illuminator (a fluorescent lamp), image input device (CCD (Charge-Coupled Device) camera), image processing system(Vision Board(FARAMVB-02)), image output device (video monitor, printer), and a measuring instrument(TELMN1000). Length measurement by visual inspection system make use of 100mm guage block(instead of calculating distance between a camera and a object). It measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measure- ment of a injection. A measuring instrument used to ompare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument with visual inspecion system using length factor of 100mm gauge block. We find that maximum error of length is 0.55mm when it compar with the measuring value of two devices(FARAMVB-02, TELMN1000). Program of visual inspection system is made up Borland C++3.1.

  • PDF

측정기의 효율적 운영에 관한 실증적 연구

  • Yu, Hyeon-Jong;Jeong, Su-Il
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.48
    • /
    • pp.64-74
    • /
    • 2009
  • Measurement is a essential part in all kinds of industry, especially in manufacturing. But until now, measurement hasn't been located to the core of manufacturing in domestic. This improvement guide line for the multilateral problems of measuring instrument investigation of small and medium-sized enterprises. To use measuring treat it must be accustomed with the structure, the performance, the method. must be corrected periodically. The correcting-schedule is established with accuracy, stability, purpose, condition, and frequency.

  • PDF

The Study for Development on Earlier Evaluation Instrument of Strength of Concrete -Outline of Experiment and Investigation on Suitability of Instrument- (콘크리트 강도 조기 판정기의 개발에 관한 연구 (1) 실험 계획 및 실험기기의 적합성 검토)

  • 김화중;이도헌;윤상천;박정민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.435-440
    • /
    • 1994
  • It is considered to pressing problem that the develpment of the rapid and simple method and measuring instrument, can evaluate for quality of concrete at early period. Accordingly in this paper proposed to earlier evaluation method on quality of concrete using resistance method and ultra-sonic pulse velocity test. It was found to the possibility of development on test method and instrument through a series of fundmental investigation.

  • PDF

A Study on Analysis of Fine Dust Measuring System to Improve Quality of Life (삶의 질 향상을 위한 미세먼지 측정 시스템 분석 연구)

  • Lee, Kwang-Jae
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.6
    • /
    • pp.69-77
    • /
    • 2019
  • Among the many factors that threaten the improvement of public health and quality of life, the proportion of fine dust is not so small, and the kinds and causes of the dust are also diversified. However, the domestic measuring instrument is in the initial stage and the certification system is insignificant. Recognizing the threat of fine dust for a long time, the United States has established a protocol of measurement standards and measurement methods and applied the developed fine dust measuring device authentication system. Through this system, the United States is leading the world's fine dust industry, technology and market. The EPA, FRM and FEM of the fine dust-related protocol were analyzed to reduce the harmful effects of repeated fine dust every year. In addition, light scattering method and spectroscopy method which can measure in real time by measuring method were examined, and the types and characteristics of fine dust measuring instrument of international certification level were analyzed. Finally, development and service plan of the domestic fine dust measuring instrument are presented.

Assessing Reliability and Validity of an Instrument for Measuring Resilience Safety Culture in Sociotechnical Systems

  • Shirali, Gholamabbas;Shekari, Mohammad;Angali, Kambiz Ahmadi
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.296-307
    • /
    • 2018
  • Background: Safety culture, acting as the oil necessary in an efficient safety management system, has its own weaknesses in the current conceptualization and utilization in practice. As a new approach, resilience safety culture (RSC) has been proposed to reduce these weaknesses and improve safety culture; however, it requires a valid and reliable instrument to be measured. This study aimed at evaluating the reliability and validity of such an instrument in measuring the RSC in sociotechnical systems. Methods: The researchers designed an instrument based on resilience engineering principles and safety culture as the first instrument to measure the RSC. The RSC instrument was distributed among 354 staff members from 12 units of an anonymous petrochemical plant through hand delivery. Content validity, confirmatory, and exploratory factor analysis were used to examine the construct validity, and Cronbach alpha and test-retest were employed to examine the reliability of the instrument. Results: The results of the content validity index and content validity ratio were calculated as 0.97 and 0.83, respectively. The explanatory factor analysis showed 14 factors with 68.29% total variance and 0.88 Kaiser-Meyer-Olkin index. The results were also confirmed with confirmatory factor analysis (relative Chi-square = 2453.49, Root Mean Square Error of Approximation = 0.04). The reliability of the RSC instrument, as measured by internal consistency, was found to be satisfactory (Cronbach ${\alpha}=0.94$). The results of test-retest reliability was r = 0.85, p < 0.001. Conclusion: The results of the study suggest that the measure shows acceptable validity and reliability.

Development of Calibrating Instrument for Tool Wear using Spindle Orientation Function in End Milling (엔드밀 가공시 주축 오리엔테이션 기능을 통한 공구마멸 보정 장치의 개발)

  • Kim, Jeon-Ha;Kang, Myung-Chang;Kim, Jeong-Suk;Kim, Kwang-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.7
    • /
    • pp.1095-1102
    • /
    • 2003
  • The most important thing in measuring the tool wear is to set up the measurement base. The end mill that is being used for machining of die is difficult to set up the base and to measure the tool wear because of geometric properties of that such as a helix and relief angle. In this study, a new instrument using spindle orientation function in end milling is developed to measure the tool wear and evaluated by the measuring system on the machine. Finally, this new method makes possible the wear measurement of same position and reduces the measuring time compared with the measuring methods such as the microscope and CCD.

Development of Calibration Instrument far Tool Wear Measurement using Spindle Orientation Function in End Milling (엔드밀 가공시 주축 오리엔테이션 기능을 통한 공구마멸측정 보정 장치의 개발)

  • 강익수;김전하;강명창;김정석;김기태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.149-153
    • /
    • 2003
  • The most important thing in measuring the tool wear is to set up the measurement base. The end mill that is being used for machining is difficult to set up the base and to measure the tool wear because of geometric properties of that such as a helix and relief angle. In this study, a new instrument using spindle orientation function in end milling is developed to measure tool wear and evaluated by measuring system on the machine. Finally, this new method makes possible the wear measurement of same position and reduces measuring time compared with measuring methods such as the microscope and CCD.

  • PDF

Review of the tracebility of impulse voltage measuring system in test laboratory (시험소 충격전압 측정시스템의 소급성검토)

  • Heo, J.C.;Choi, I.S.;Jeong, J.Y.;Ban, S.G.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1632-1634
    • /
    • 2003
  • For lihgtning and switching impulse voltage performances in laboratories, impulse voltage measuring system, which is consisted of voltage divider, recording instrument and connecting system between divider and recording instrument, is used. In order to show reliability of test result in test laboratory, tracebility of these measuring system to be using in test laboratory is needed. In this paper, we describe tracebility and uncertainty of impulse voltage measuring system in test laboratory.

  • PDF

Development of Korean Elderly Life Quality Scale (한국노인의 '삶의 질'에 관한 측정도구 개발)

  • Choi, Soo-Jeong
    • Korean Journal of Adult Nursing
    • /
    • v.14 no.3
    • /
    • pp.401-410
    • /
    • 2002
  • Purpose: This research was designed to develop an instrument that can be used for measuring of the quality of life for the elderly in Korea. Method: Subjects were 2,110 aged people, residing in Seoul and Kyeungi-Do. In developing this instrument, the researcher first established a conceptual framework based on the literature review and interview and open questionnaire. The collected data were analyzed using the SPSS-WIN program. For the component factors of the measuring instrument, a factor analysis method and item analysis was used. The reliability of the scale was tested by Cronbach's alpha. Result: 1) The results of the analysis of the 32 items making up the instrument were classified into the following 4 factors: life stability, easy of resource utility, health and affection in family, establishment of supportbase. 2) The reliability of the instrument for the quality of life was 0.952 (Cronbach's alpha). In the factor analysis Cronbach's alpha correlations for the 4 factors ranged from 0.736 to 0.949. Conclusion: This scale could be adequately applied in assessing the quality of life for the elderly in Korea. And the results of this scale in a study can contribute to the promotion of quality of life for the elderly.

  • PDF

Development of an Instrument to Measure the Readiness of an Organization for Knowledge Management (조직의 지식경영 준비도(Readiness) 측정도구 개발에 관한 연구)

  • Kim, Hyogun;Kwon, Hee-Young;Jeong, Seong-Hwi
    • Knowledge Management Research
    • /
    • v.2 no.1
    • /
    • pp.45-63
    • /
    • 2001
  • The role of knowledge as the key source of potential advantage for organizations and economies has become a hotly debated topic. Some studies found that organizations had their own knowledge management styles. Knowledge Management draws form existing resources that organizations may already have in place. Checking the organization's infrastructures for Knowledge Management is the first step for Knowledge Management. Although the as- is analysis of organizations before knowledge management is important, but there is no study on the readiness for Knowledge Management. This study reports on the development of an instrument designed to measure the readiness of an organization for knowledge Management. Starting with the literature, 4 dimensions - strategy, process, culture/people, and technology - and 18 factors were identified. Then, a questionnaire for measuring readiness was created. Finally, the instrument was pilot tested to prove its reliability and validity. Following the pilot test, the factors all demonstrated acceptable levels of reliability. The result is 19 factors instrument comprising 4 dimensions which provide a useful tool for measuring the readiness for Knowledge Management.

  • PDF