• 제목/요약/키워드: measuring impedance

검색결과 318건 처리시간 0.028초

비침습적 복압 측정을 위한 생체 임피던스 전극의 최적 위치 선정 (Optimum electrode selection for measuring the abdominal pressure using bio-impedance method)

  • 안양수;김거식;송철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.46-48
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2$+0.0620x+0.6958, respectively. It demonstrated that the abdominal pressure could be measured non-invasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

  • PDF

접지 그리드에서의 보조전극 배치에 따른 접지임피던스 측정 및 분석 (Measurement and Analysis of Ground Impedance according to Arrangement of Auxiliary Probe around Ground Grid)

  • 길형준;송길목;김영석;김종민
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.46-50
    • /
    • 2015
  • This paper describes the measurement and analysis of ground impedance according to arrangement of auxiliary probe around ground grid using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method involves passing a current between a ground electrode and a current probe, and then measuring the voltage between a ground electrode and a potential probe. To minimize interelectrode influences due to mutual resistances, the current probe is a generally placed at a substantial distance from the ground electrode under test. In order to analyze the effects of ground impedance due to the arrangement of auxiliary probe and frequency, ground impedances were measured in case that the arrangements of auxiliary probe were straight line, perpendicular line, and horizontal line. The distance of current probe was located from 10[m] to 200[m] and the measuring frequency was ranged from 55[Hz] to 513[Hz]. As a consequence, the ground impedance increases with increasing the distance from the ground electrode to the point to be tested, but the ground impedance decreases with increasing the frequency.

가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법 (A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter)

  • 이복희;엄주홍
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

초정밀가공 시 임피던스 측정을 통한 시편 수평맞춤 및 공구의 기준위치 설정 (Workpiece Horizontality and Reference Positioning of Cutting Tool by Measuring Impedance in Ultra-Precision-Machining)

  • 이호철;김기대
    • 한국정밀공학회지
    • /
    • 제28권12호
    • /
    • pp.1366-1371
    • /
    • 2011
  • In ultra precision machining, it is necessary to adjust the horizontality and reference position of a workpiece in a noncontact manner. For this, a simple process by measuring impedance between a tool tip and a workpiece which are connected to impedance analyzer is proposed. As the distance between the tool and the workpiece gets closer, the reduction rate of impedance becomes higher over all frequency ranges. By setting threshold value of impedance reduction rate at specific frequencies through preliminary experiments, the distance between the tool and the workpiece can be predicted and it directly enables us to horizontalize the workpiece and to set the tool to the desired reference position.

절연유-절연지에서 이중 임피던스에 의해 부분방전측정 (Partial Discharge Measurement of Oil-Paper Insulation by Dual Measuring Impeadance)

  • 김광화;류희석;선종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1778-1780
    • /
    • 1996
  • In this paper, we describe the partial discharge measurement with measuring impedance to have two wide frequency band transformers(filters) in the oil-paper and air insulation. The measuring impedance consists of high and low limiting frequency transformers. This measuring impedance could be measured the partial discharge current wave. We have the results that the amplitude partial discharge pulse ratio of low limiting frequency tranformer to high limiting frequency one is varied in the condition(in oil-paper insulation and air) to generate partial discharge.

  • PDF

휴대용 체지방계의 개발 (The Development of Portable Body Fat Meter)

  • 박종찬;임응춘;박수홍;한운동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.34-37
    • /
    • 2003
  • The purpose of this paper is the development of portable body fat meter. Bioelectrical impedance method for measuring human body composition is based upon the principle that the electrical conductivity of the fat mass is far greater than that of the fat. Finally measurement of percent body fat was made possible using a developed impedance measuring device which measure impedance between the thumb and ring finger.

  • PDF

Loop Impedance 측정을 통한 접지계통 비교분석

  • 정진수;한운기;김오환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.211-212
    • /
    • 2009
  • This Paper present about loop impedance measuring method by a comparison & analysis of the earthing systems in IEC60364. And comparing analysis about only considering a resistance and considering resistance & inductance. Result, For measuring of loop impedance than must measured resistance and reactance. And TT earthing system was lower fault current then TN systems, but an electric shock was higher then TN systems.

  • PDF

변전소와 차량간의 동기화를 통한 실시간 전차선로 임피던스 예측 기법 연구 (A Study on Real Time Catenary Impedance Estimation Technique using the Synchronized Measuring Data between Substation and Train)

  • 정호성
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1458-1464
    • /
    • 2013
  • This paper proposed a new real time catenary impedance estimation technique using synchronized power data from the measured data of operating vehicle and substation for catenary protective relay and fault locator setting. This paper presented estimation equation of catenary impedance using synchronized power data between substation and vehicle of AT feeding system for the performance verification of the proposed technique. Also AC feeding system is modeled through power analysis program and performance was verified through simulation according to various load changes. We verified that average 2.38%(distance equivalent 23.8 m) error appeared between the proposed estimation equation of catenary impedance and power analysis program simulation output in no connection double track system between up track and down track. Furthermore, We confirmed that estimation error is bigger depending on the increasing the distance from substation and vehicle impedance using only using vehicle current when calculating vehicle impedance in connection double track system between up track and down track. But, We confirmed that the proposed technique estimated accurately catenary impedance regardless of vehicle impedance and distance from substation.

전류보조전극 거리 및 주파수에 따른 접지임피던스 특성 (Characteristics for Ground Impedance according to Distance of Current Probe and Frequency)

  • 길형준;이기연;문현욱
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.122-128
    • /
    • 2010
  • 본 논문에서는 전위강하법을 이용한 전류보조전극의 거리 및 주파수에 따른 조합형 봉형 접지전극의 접지임피던스 특성을 다루고, 측정오차를 최소화하기 위한 방법을 제안하였다. 전위강하법은 전압과 전류 측정원리에 기반을 두고 측정오차는 보조전극의 위치에 의해 발생한다. 전류보조전극의 거리와 주파수에 기인한 접지임피던스 영향을 분석하기 위해 전류보조전극의 거리를 5~20[m]로 변화시키며 측정이 이루어졌고, 55~513[Hz]로 측정주파수를 변화시키며 특성을 분석하였다. 연구결과는 접지시스템에서 접지임피던스를 측정할 경우에 전류보조전극의 위치와 측정주파수를 결정하는데 활용될 수 있다.

Remote Impedance-based Loose Bolt Inspection Using a Radio-Frequency Active Sensing Node

  • Park, Seung-Hee;Yun, Chung-Bang;Inman, Daniel J.
    • 비파괴검사학회지
    • /
    • 제27권3호
    • /
    • pp.217-223
    • /
    • 2007
  • This paper introduces an active sensing node using radio-frequency (RF) telemetry. This device has brought the traditional impedance-based structural health monitoring (SHM) technique to a new paradigm. The RF active sensing node consists of a miniaturized impedance measuring device (AD5933), a microcontroller (ATmega128L), and a radio frequency (RF) transmitter (XBee). A macro-fiber composite (MFC) patch interrogates a host structure by using a self-sensing technique of the miniaturized impedance measuring device. All the process including structural interrogation, data acquisition, signal processing, and damage diagnostic is being performed at the sensor location by the microcontroller. The RF transmitter is used to communicate the current status of the host structure. The feasibility of the proposed SHM strategy is verified through an experimental study inspecting loose bolts in a bolt-jointed aluminum structure.