HDTV SMPS Aging System을 위한 원격 계측 제어 시스템 개발 (Development of the Telemetering Control System for the HDTV SMPS Aging System)

  • 김병욱;임승관;고대성;노신래;김영민
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.56-61
    • /
    • 2009
  • In this paper, A telemetering control system for the HDTV SMPS Aging System is developed. Manual Aging System is usually used to measurement of a produced SMPS. But in this system, the respective operator is arranged and monitoring the test cycle visually- According to an excess of the test time and mistakes of an operator, the reliability makes come to be low. Therefore as using the telemetering control system, it improves a productivity and a reliability of the HDTV SMPS. In the developed system, elec1rical signal is measured from aging system, and converted into the digital signal. Also the telemetering control system is composed of many units - telemetering control units for collecting the data, data relay units for the digital transmission service, data division for the multichannel realization.

A geometric approach to fault diagnosis algorithm in linear systems

  • Kim, Jee-Hong;Bien, Zeungnam
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1216-1221
    • /
    • 1990
  • An algorithm for multiple fault diagnosis of linear dynamic systems is proposed. The algorithm is constructed by using of the geometric approach based on observation that, when the number of faulty units of the system is known, the set of faulty units can be differentiated from other sets by checking linear varieties in the measurement data space. It is further shown that the system with t number of faults can be diagnosed within (t+1) sample-time units if the input-output measurements are rich and that the algorithm can be used for diagnosis even when the number of faults is not known in advance.

  • PDF

사고전동차 구조체의 안전진단에 관한 고찰 (On Study the Safety Diagnosis of Carbody Structure for Crashed Electric Multiple Units)

  • 배대성;박근수;정종덕
    • 한국철도학회논문집
    • /
    • 제8권3호
    • /
    • pp.253-259
    • /
    • 2005
  • This paper describes 3D Dimensional Measurement(EDM testing) and tensile testing results of carbody structure for crashed EMU(Electric Multiple Units). Tensile tests were performed on two different types of specimens in order to evaluate the strength changes before and after damages, obtained from plastic deformed area and nondeformed region of the crashed EMU. And Structural analysis of EMU was performed for the criteria of safety assessment. Structural analysis using commercial I-DEAS software provided important information on the stress distribution and load transfer mechanisms as well as the amount of damages during rolling stock crash. The testing results have been used to provide the critical information for the criteria of safety diagnosis.

대학주변 원룸형 다가구주택의 소음측정평가 (Evaluation on Noise Level of One-Room Type Multi-Family Housing Around Campus)

  • 최윤정
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.95-100
    • /
    • 2003
  • The purpose of this study is to evaluate the noise environment of one-room type multi-family housing around the campus. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the 26th${\sim}$28th of November 2002. The results are as follows. 1) Outdoor noise levels of 6 subject buildings were distributed 52.8${\sim}$65.3dB(A) and were inappropriate to the standard for environmental noise, 55dB(A). 2) Indoor noise level of 6 subject house units were measured 27.5${\sim}$63.5dB(A). These values were higher than the indoor noise standard (40dB(A)) except subject house D(average 37.6dB(A)). 3) It was found that the differences of indoor noise levels between subject house units were caused by resident's living factor, characteristics of window, and existence of balcony.

  • PDF

가압식 오실로메트릭 방법을 사용한 혈압측정 시스템의 설계 (Design of the Blood Pressure Measurement System Using the Inflatable Oscillometric Method)

  • 노동곤;이윤선;지정호;박성빈;이계형;김해관
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.281-286
    • /
    • 2003
  • 혈압은 사람의 건강상태를 알 수 있는 가장 기본적인 의학적 파라메터 중 하나이며, 오실로메트릭 방법을 사용한 혈압측정 시스템은 팔 동맥에서 커프를 통해 나타나는 압력을 측정함으로써 혈압수치를 비침습적으로 모니터링 하는 장치이다. 된 논문에서는 커프에 공기를 주입하면서 혈압을 측정하는 가압식 손목형 혈압측정 시스템을 설계하였다 설계한 혈압측정 시스템은 전원부와 압력을 가하는 공기주머니를 포함하는 커프, 신호검출부, 신호처리부, 무선 송수신부 그리고 디스플레이부로 구성된다. 설계한 자동 혈압측정 시스템은 기존에 일반적으로 사용되고 있는 자동혈압측정 시스템과의 수축기, 이완기 혈압 및 심박동수의 비교분석을 통해 신뢰성을 평가하였다. 수축기 혈압과 이완기 혈압을 결정하기 위해 MAA (Maximum Amplitude Algorithm)를 사용하였고, 적용한 특성비율은 0.436. 0.671이 었다.

평면 오차 보정 가공을 위한 측정 방법에 관한 연구 (A Measurement Method to Compromise Surface Error in Machined Workpieces)

  • 장문주;홍성욱;박천홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.409-412
    • /
    • 2002
  • This paper presents a measurement method to compromise surface error in surface machining processes. In order to compromise the surface error in machining process, on-machine measurement is essential. There are two kinds of on-machine measurement methods available to measure the surface errors in flat workpieces: i.e., surface scanning method and sensor scanning method. However, motion errors are inevitably engaged in both methods. This paper proposes a new idea to measure the surface error for error compensation. The measurement system consists of a laser, a CCD camera and processing system, a carrier system with a stylus, and some optical units. The experimental results show that the proposed method is useful to compensate the surface errors of machined workpieces.

  • PDF

측정데이터를 이용한 실시간 정적 부하모델링 (On-line Static Load Modeling using Measurement Data)

  • 박상현;정동현;강상균;이병준;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.282-284
    • /
    • 2006
  • In this paper, Static load models are developed using measurement based approach which is fundamental for on-line load modeling. The measurement data can be acquired from PMU(phasor measurement units). On the assumption that we have on-line measurement data, a scheme which is for Static load model capable to apply SCADA/EMS is developed. The Least Squares criterion is used for minimizing between measured and simulated data. In this manner, On-line Static load modeling algorithm can be developed. In this paper, a scheme that simple Static load model is applied for On-line load modeling is studied.

  • PDF

휴대용 무선 응급 단말기 및 통합 시스템 개발 (Development of Portable Wireless Emergency Units and Integrated System)

  • 송미혜;명현석;이경중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2161-2162
    • /
    • 2006
  • In this study, we developed five mobile units and an integrated system which can manage vital signs from each unit using Bluetooth wireless communication. The five kinds of mobile unit were so designed that each has different function to be applied according to the condition of patient properly. The mobile units can measure ECG signal of single or 12 channel, blood pressure, pulse and SpO2 signal from a patient. Also, to reduce the uncomfortable measurement, several types of units such as belt type, wrist type and necklace type were designed. Our proposed system can integrate and monitor several biological signals from different patient by using Bluetooth wireless communication simultaneously. The developed system was evaluated in the simulated emergent situation and showed the system can monitor 5 patients in maximum according to the data quality. It showed the possibilities that the developed system can be used effectively for emergency situation or in- or out-hospital transport of patient. In future, with the combination of mobile communication technique, a patient who is in emergency situation can be provided with proper first-aid and a doctor can pile information of patient and give better diagnosis and treatments.

  • PDF

화력발전소의 미세먼지 배출특성 (Emission Characteristics of Fine Particles from Thermal Power Plants)

  • Park, Sooman;Lee, Gayoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.455-460
    • /
    • 2020
  • In order to identify the characteristics of fine particle emissions from thermal power plants, this study conducted measurement of the primary emission concentration of TPM, PM10 and PM2.5 according to Korea standard test method (ES 01301.1) and ISO 23210 method (KS I ISO 23210). Particulate matters were sampled in total 74 units of power plants such as 59 units of coal-fired power plants, 7 units of heavy oil power plants, 2 units of biomass power plant, and 6 units of liquid natural gas power plants. The average concentration of TPM, PM10, PM2.5 by fuel are 3.33 mg/m3, 3.01 mg/m3, 2.70 mg/m3 in coal-fired plant, 3.02 mg/m3, 2.99 mg/m3, 2.93 mg/m3 in heavy oil plant, 0.114 mg/m3, 0.046 mg/m3, 0.036 mg/m3 in LNG plant, respectively. These results of TPM, PM10 and PM2.5 were satisfied with the standards of fine dust emission allowance in all units of power plants, respectively. Also, this study evaluated the characteristics of fine particle emissions by conditions of power plants including generation sources, boiler types and operation years and calculated emission factors and then evaluated fine particle emissions by sources of electricity generation.