• Title/Summary/Keyword: measurement scale

Search Result 2,630, Processing Time 0.03 seconds

A Study on Measurement Accuracy of Theodolite System(II) -A Measurement Accuracy for a Height of Scale Bar (데오드라이트 시스템의 측정 정확도에 대한 연구(II) -기준자 측정 높이에 따른 측정 정확도)

  • 윤용식;이동주;정종길
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.37-43
    • /
    • 2004
  • A measurement accuracy of theodolite system may be affected by a measurement environment, a measurement distance change and so on. This study was performed for measuring an accuracy when the height of scale bar is changed 0.05m, 0.5m, 1m and 1.5m under the distance 3m between two theodolites, the distance 4m from the theodolite system to scale bar and the distance 5m from the thodolite system to the horizontal target bar. And we could know that the best height is 0.05m and 1m.

Development of body-fat measurable electronic scale. (체지방측정이 가능한 전자식 체중계의 개발)

  • Choi, Byung-Sang;Kim, Il-Hwan;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.243-248
    • /
    • 2006
  • The purpose of this study is to design a body-fat measurable electronic scale which can measure body impedance and weight. The hardware configuration of this system for the body-fat measurement includes a sinewave constant current generator, a analog switch circuit and a microprocessor with peripheral interface as well as electronic scale circuit. And the dedicated software is also designed for calculating body fat and body composition analysis from the result of the measurement.

  • PDF

A Study on Measurement Accuracy of A Theodolite System(V) - A Measurement System Accuracy depending on the distance from theodolite system to target Bars (데오드라이트 시스템의 측정 정확도에 대한 연구(V) - 타켓 바의 거리에 따른 측정 정확도)

  • Yoon Yong-Sik;Lee Dong-Ju
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.4
    • /
    • pp.13-21
    • /
    • 2005
  • The affected factors for an accuracy of theodolite system are not only the measurement environment of temperature, illumination, etc. but also the measurement processes of the distance between two theodolites, the distance from theodolite system to scale bar and the distance from theodolite system to targets. We have known that the best collimation distance between two theodolites and the best distance from theodolite system to scale bar is $3{\sim}4m$. This study was performed for searching the best distance from theodolite system to targets on above measurement configuration. And, we could know that the best distance from theodolite system to targets is $2{\sim}6m$ and the system accuracy could be within ${\pm}0.025mm$.

Suppliers Measurement of Channel Member Performance in Korea (우리 나라 공급업체의 유통경로구성원 성과 특정)

  • 김종훈;한장희
    • Journal of Distribution Research
    • /
    • v.4 no.2
    • /
    • pp.21-39
    • /
    • 1999
  • This study investigates the general applicability of the measurement scale for assessing channel-member performance for the supplier's view that was proposed by Kumar, and Achrol (1992). First, we attempted to examine whether the measurement-scale could be used without any change; the results from the initial data-analysis proposed that the scale needed a certain amount of a revision for further utilization. It seemed that the scale needed some adjustment for being applied to this study; their scale was developed with the data collected from the network of independent dealers handling multiple product items or multiple brands in the U.S. and Canada, while the data of this study were provided by a Korean car manufacturer having a dealer network selling and servicing only its own brand without ownership. Accordingly, we determined that it was necessary to develop a newly finalized performance-measurement scale revising Kumar et al.'s. During the data-analysis of the data resulted in a scale of fifteen items measuring three facets-financial performance, behavioral performance, and competence, each of which consisted of five items respectively. This empirically developed scale looked more valid for the situation of this study than the Kumar, Stern, and Achrol's which was composed of twenty-one items measuring seven facets--three items each.

  • PDF

Flexible camera series network for deformation measurement of large scale structures

  • Yu, Qifeng;Guan, Banglei;Shang, Yang;Liu, Xiaolin;Li, Zhang
    • Smart Structures and Systems
    • /
    • v.24 no.5
    • /
    • pp.587-595
    • /
    • 2019
  • Deformation measurement of large scale structures, such as the ground beds of high-rise buildings, tunnels, bridge, and railways, are important for insuring service quality and safety. The pose-relay videometrics method and displacement-relay videometrics method have already presented to measure the pose of non-intervisible objects and vertical subsidence of unstable areas, respectively. Both methods combine the cameras and cooperative markers to form the camera series networks. Based on these two networks, we propose two novel videometrics methods with closed-loop camera series network for deformation measurement of large scale structures. The closed-loop camera series network offers "closed-loop constraints" for the camera series network: the deformation of the reference points observed by different measurement stations is identical. The closed-loop constraints improve the measurement accuracy using camera series network. Furthermore, multiple closed-loops and the flexible combination of camera series network are introduced to facilitate more complex deformation measurement tasks. Simulated results show that the closed-loop constraints can enhance the measurement accuracy of camera series network effectively.

A Study on Measurement Error Factors of Theodolite System (데오도라이트 시스템의 측정 오차 요인에 대한 연구)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.4
    • /
    • pp.36-42
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is ${\pm}0.5mm$or better for distance 0~100m. And the system is used for the measurement of a product of middle and large scale. This study is performed for the measurement error factors of the system. We could know that the main measurement error factors are temperature, illumination and skill. Also, we performed the study for the effect according to the height difference of scale bar.

A Study on Measurement Uncertainty of Theodolite System (데오도라이트 시스템의 측정 불확도 연구)

  • 이건탁;이동주;박흥철;오재명
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.229-233
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is 0.5 mm or better for distance 0 ~ 100m. And the system is used for a product of middle and large scale. This study is performed for the measurement uncertainty of the system. We could know that the main uncertainty factors are temperature, illumination and skill. And, we perform the study for the effect according to the height difference of scale bar. And, we calculated the measurement uncertainty with those factors.

  • PDF

Evidence from Turkish and Syrian People for the Measurement Invariance of the CBBE Scale and Clues for the Distribution Strategies of the Brands

  • Ahmet KAYAOGLU;Yavuz Selim GULMEZ
    • Journal of Distribution Science
    • /
    • v.21 no.5
    • /
    • pp.75-82
    • /
    • 2023
  • Purpose: This research aims to test the measurement invariance of the consumer-based brand equity scale on Turkish and Syrian university students who live together but are from different cultural groups. Research design, data, and methodology: The consumer-based brand equity scale developed by Buil et al. (2008) is applied to the participants. In testing the consumer-based brand equity scale, the Netflix brand, which is considered well-known by both cultural groups, is preferred. It is thought that choosing an internationally recognized brand would facilitate the conduct of this research. Structural invariance and measurement invariance are tested using structural equation modeling. Results: The consumer-based brand equity scale has measurement invariance on Turkish and Syrian university students. Therefore, it has been revealed that the responses of participants from both cultures regarding the Netflix brand are comparable. Conclusion: The findings of the study provide clues for practitioners to review their distribution strategies. As a matter of fact, cultural studies conducted in different countries are common. Still, the originality of this study is ensured by the profile of participants who live in the same country but come from different countries.

A Theoretical Review for developing a Korean Type Marital Satisfaction Scale (한국형 결혼만족도 척도 개발을 위한 이론적 고찰)

  • 정현숙
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.11
    • /
    • pp.89-106
    • /
    • 2001
  • The purpose of this study is to critically review the related issues of marital satisfaction scale in order to develop a Korean Type Marital Satisfaction Scale. Especially definitional ambiguity, unit of analysis theory of marital satisfaction and issues about measurement and cultural implication are reviewed. Also a section deals with suggestions that could be considered to develop Korean Type Marital Satisfaction Scale.

  • PDF

Development of electro-spray micro-thruster and measurement of nano-scale thrust (Electro-spray 마이크로 추진 장치 개발 및 나노 크기의 힘 측정)

  • Lee Young-Jong;Si Bui Quang Tran;Byun Do-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.45-48
    • /
    • 2007
  • Conventional force sensors such as piezoelectric sensor has limitations for measuring micro/nano-scale thrust. In this study we developed nano-scale measurement system using laser displacement sensor and cantilever. And electrospray microthruster was fabricated by using stainless capillary and extraction electrode, to generate nano-scale thrust. The measurement system can measure the around 90 nN thrust from this thruster. In addition, we designed and fabricated electrospray micro thruster based on PMMA(Polymethyl methacrylate), which has a nozzle protruded from the substrate.

  • PDF