A Study on Measurement Accuracy of A Theodolite System(V) - A Measurement System Accuracy depending on the distance from theodolite system to target Bars  

Yoon Yong-Sik (한국항공우주연구원 우주시험그룹)
Lee Dong-Ju (충남대학교 기계공학과)
Publication Information
Transactions of the Korean Society of Machine Tool Engineers / v.14, no.4, 2005 , pp. 13-21 More about this Journal
Abstract
The affected factors for an accuracy of theodolite system are not only the measurement environment of temperature, illumination, etc. but also the measurement processes of the distance between two theodolites, the distance from theodolite system to scale bar and the distance from theodolite system to targets. We have known that the best collimation distance between two theodolites and the best distance from theodolite system to scale bar is $3{\sim}4m$. This study was performed for searching the best distance from theodolite system to targets on above measurement configuration. And, we could know that the best distance from theodolite system to targets is $2{\sim}6m$ and the system accuracy could be within ${\pm}0.025mm$.
Keywords
Theodolite; Scale Bar; Target Bar; Collimation; Measurement Accuracy; Measurement Precision; Measurement System Accuracy;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Yoon, Y. S. and Lee, D. J., 2002, 'Measurement Technology and Trend of Non-contacted 3-Dimension Precision Coordinate Measurement of Middle-Large Structure,' Journal of the KSMTE, Vol. 11, No. 1, pp. 7-13
2 Sandwith, S. C., 1993, 'Gageless Tool Building with Computer-Aided Theodolites,' Leica Practice Report, Leica co. Ltd
3 Hong, J. H., 1998, The Fundamental of Measurement Engineering, Sigma Press
4 Yoon, Y. S., Lee, D. J., and Cheong, J. G., 2004, 'A Study on Measurement Accuracy of Theodolite System(II) - A Measurement Accuracy for a Height of Scale Bar,' Transactions of the KSMTE, Vol. 13, No. 4, pp. 37-43
5 Yoon, Y. S., Lee, D. J., and Yoon, I. J., 2005, 'A Study on Measurement Accuracy of Theodolite System (III) - A Measurement System Accuracy depending on a distance of Scale Bar on the Distance 3m between two Theodolites,' Transactions of the KSMTE, Vol. 14, No. 2., pp. 48-54
6 Yoon, Y. S., 2004, A Study on Measurement Accuracy Improvement of Theodolite System, Chungnam Univ. Ph. D. Thesis
7 Yoon, Y. S. and Lee, D. J., 2004, 'A Study on Measurement Accuracy of Theodolite System(I) - A Measurement Accuracy According to a Theodolite Collimation Distance,' Transactions of the KSMTE, Vol. 13, No. 2, pp. 61-68
8 Yoon, Y. S., Lee, D. J. and Park, Y. C., 2005, 'A Study on Measurement Accuracy of Theodolite System (IV) - A Measurement System Accuracy depending on a distance of Scale Bar on the Distance 4m between two Theodolites,' Transactions of the KSMTE, Vol. 14, No. 3
9 Yoon, Y. S. and Lee, D. J., 2003, 'A Study on Measurement Error Factors of Theodolite System,' Transactions of the KSMTE, Vol. 12, No. 4, pp. 36-42
10 Yoon, Y. S., Lee, J. Y., Cho, C. R., and Lee, S. S., 2001, '3-Dimensional Precision Measurement of Spacecraft Structure Test Model,' Proceedings of the KSPE Spring Conference, pp. 131-134
11 Cohen, D. and Brydon, L., 1998, 'Reflector Surface Thermal Stability Measurement,' CMSC Annual Conference
12 Nakazawa, H., 1994, Principles of Precision Engineering, Oxford Univ. Press