Measurement of thermal contact resistance at Cu-Cu interface

  • Kim, Myung Su;Choi, Yeon Suk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권2호
    • /
    • pp.48-51
    • /
    • 2013
  • The thermal contact resistance (TCR) is one of the important components in the cryogenic systems. Especially, cryogenic measurement devices using a cryocooler can be affected by TCR because the systems have to consist of several metal components in contact with each other for heat transferring to the specimen without cryogen. Therefore, accurate measurement and understanding of TCR is necessary for the design of cryogenic measurement device using a cryocooler. The TCR occurs at the interface between metals and it can be affected by variable factors, such as roughness of metal surface, contact area and contact pressure. In this study, we designed TCR measurement system at various temperatures using a cryocooler as a heat sink and used steady state method to measure the TCR between metals. The copper is selected as a specimen in the experiment because it is widely used as a heat transfer medium in the cryogenic measurement devices. The TCR between Cu and Cu is measured for various temperatures and contact pressures. The effect of the interfacial materials on the TCR is also investigated.

An international Comparison Measurement of Silicon Wafer Sheet Resistance using the Four-point Probe Method

  • Kang, Jeon-Hong;Ying, Gao;Cheng, Yuh-Chuan;Kim, Chang-Soo;Lee, Sang-Hwa;Yu, Kwang-Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.325-330
    • /
    • 2015
  • With approval from the Asia Pacific Metrology Program Working Group on Materials Metrology (APMP WGMM), an international comparison for sheet resistance standards for silicon wafers was firstly conducted among Korea Research Institute of Standards and Science (KRISS) in Korea, CMS/ITRI in Taiwan, and NIM in China, which are national metrology institutes (NMIs), from August 2011 to January 2012. The sheet resistance values of the standards are $10{\Omega}$, $100{\Omega}$, and $1000{\Omega}$; the measurement was conducted in sequence at KRISS, CMS/ITRI, NIM, and KRISS again using the four-point probe method with single and dual configuration techniques. The reference value for the measurement results of the three NMIs was obtained through averaging the values of the three results for each sheet resistance range. The differences between the reference value and the measured values is within 0.22% for $10{\Omega}$, 0.17% for $100{\Omega}$, and 0.12% for $1000{\Omega}$. Therefore, the international consistency for conducting sheet resistance measurements is confirmed within 0.22% through the APMP WGMM approved comparison.

변이율을 활용한 접지저항 측정 기술 (Ground Resistance Measurement Technology Utilizing the Variation Rate)

  • 이상무
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.51-56
    • /
    • 2005
  • 접지의 성능을 결정하는 기본 요소인 접지저항을 측정하는 것은 성능평가를 위한 중요한 기술이 된다. 접지저항의 정확한 측정을 위하여는 측정 환경상 고려하여야 할 주요한 변수들이 있는데 실제의 측정 현장에서 이러한 변수들을 알고 측정하기는 곤란한 것이 현실이다. 본 논문에서는 3점전위강하법상의 전류전극에 이르기까지 나타나는 전위차 특성 곡선에 대하여 측정 환경 변수의 특성을 내포하고 있는 변이율이라는 개념을 도입하여 미지의 측정 환경 변수중에서도 가능한 접지저항의 참값에 근접한 측정을 지향하는 방법을 제의한 것이다. 이 이론은 이미 기검증된 논문들의 결과 내용을 분석함으로써 귀납적인 결론을 유도한 것이다.

직류 전압/저항 비율 초정밀 측정기술 (Precision Measurement Technique of DC Voltage/Resistance Ratio)

  • 김규태;유광민
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권3호
    • /
    • pp.96-99
    • /
    • 2002
  • We developed 1:1 resistance ratio measurement system for precision measurement of a series-resistor type dc voltage divider. By using active guard technique and exchange technique, any leakage effects, which are one of the most critical error sources, were successfully removed. The best measurement uncertainty with the developed ratio measurement system was estimated to be approximately $10^{-8}\;for\;10\;k{\Omega}\;and\;100\;k{\Omega}$.

극저온에서 금속표면의 열 접촉 저항 측정 (Thermal Contact Resistance Measurement of Metal Interface at Cryogenic Temperature)

  • 김명수;최연석
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.32-37
    • /
    • 2014
  • The thermal contact resistance (TCR) is one of the important resistance components in cryogenic systems. Cryogenic measurement devices using a cryocooler can be affected by TCR because the device has to consist of several metal components that are in contact with each other for heat transfer to the specimen without a cryogen. Therefore, accurate measurement and understanding of TCR is necessary for the design of cryogenic measurement devices using a cryocooler. The TCR occurs at the interface between metals and it can be affected by variable factors, such as the roughness of the metal surface, the contact area and the contact pressure. In this study, we designed a TCR measurement system at variable temperature using a cryocooler as a heat sink. Copper was selected as a specimen in the experiment because it is widely used as a heat transfer medium in cryogenic measurement devices. We measured the TCR between Cu and Cu for various temperatures and contact pressures. The effect of the interfacial materials on the TCR was also investigated.

동전위 분극저항 측정에서의 불확도 (Uncertainty in Potentiodynamic Polarization Resistance Measurement)

  • 김종집
    • Corrosion Science and Technology
    • /
    • 제8권5호
    • /
    • pp.193-196
    • /
    • 2009
  • For the estimation of uncertainty in potentiodynamic polarization resistance measurement, the type A uncertainty was measured using type 316 stainless steel in an acidified NaCl solution. Sensitivity coefficients were determined for measurand such as scan rate of potential, temperature of solution, concentration of NaCl, concentration of HCl, surface roughness of specimen and flow rate of purging gas. Sensitivity coefficients were large for the measurand such as the scan rate of potential, temperature of solution and roughness of specimen. However, the sensitivity coefficients were not the major factors influencing the combined standard uncertainty of polarization resistance due to the low values of uncertainty in measurements of the measurands. A major influencing factor was the concentration of NaCl. The value of type A uncertainty was 1.1 times the value of type B uncertainty, and the combined standard uncertainty was 10.5 % of the average value of polarization resistance.

대체 보조전극을 이용한 접지저항 측정 신뢰성 분석 (Trust Analysis of Ground Resistance Measurements by the Substitute Auxiliary Electrode)

  • 이상익;유재근;전정채;전현재
    • 전기학회논문지P
    • /
    • 제56권2호
    • /
    • pp.109-114
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance. The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding a trust analysis of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a neutral line multiplex ground to earth, a wire net for auxiliary electrode. This information is confirmed bv compared with the measurement value.

친환경자동차의 전기안전을 위한 절연저항 측정에 관한 연구 (A Study on the Insulation Resistance Measurement Technique for Electrical Safety of Green Car)

  • 이기연;김동욱;김향곤;문현욱
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.597-601
    • /
    • 2009
  • Green car such as a hybrid electrical vehicle and fuel cell vehicle is developed as a commercial target. UN/ECE/WP29 is developing GTR of HFCV and establishing the regulation and standard of electrical safety by ELSA. The regulation and standard about Electrical safety of vehicle are prescribed in ISO, UN/ECE, FMVSS, Japanese Attachment and so on, in case of insulation resistance is referred to keep more than 100/Vdc, 500/Vac. However, accurate method to measure insulation resistance agreeable to structure of vehicle does not exist now, it is actually that correctness of measurement drops according to the feature of battery and fuel cell stack. In this paper, the method to measure insulation resistance for protection against electrical shock by direct contact or indirect contact in Green Car will be indicated by making a comparison between the insulation measurement in standard of electrical safety and the experiment results for HEV and HFCV.

지표면전위 해석에 의한 접지저항 측정기법에 관한 연구 (A Study on the Measurement of Grounding Resistance based on the Earth Surface Potential Analysis)

  • 윤장완;안용호;정길조;한병성
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.117-123
    • /
    • 2002
  • 접지저항의 측정은 접지계통의 접지성능이 적정한가를 평가하기 위한 가장 기본적이고 중요한 작업이라고 할 수 있다. 그러나 실제 현장에서, 특히 접지극의 크기가 큰 경우일수록 접지저항을 정확히 측정하기란 쉽지 않은데, 이는 정확한 접지전위 측정을 위한 기준전위 점을 찾기가 힘들기 때문이다. 본 논문에서는 접지극 주변에서 측정한 지표면전위를 분석하여 기준전위 점의 위치를 정확히 식별하는 방법과 그 정당성을 제시하였다.

Monitoring Failure Behaviour of Pultruded CFRP Composites by Electrical Resistance Measurement

  • Mao, Yaqin;Yu, Yunhua;Wu, Dezhen;Yang, Xiaoping
    • Carbon letters
    • /
    • 제5권1호
    • /
    • pp.18-22
    • /
    • 2004
  • The failure behaviours of unidirectional pultruded carbon fiber reinforced polymer (CFRP) composites were monitored by the electrical resistance measurement during tensile loading, three-point-bending, interlaminar shear loading. The tensile failure behaviour of carbon fiber tows was also investigated by the electrical resistance measurement. Infrared thermography non-destructive evaluation was performed in real time during tensile test of CFRP composites to validate the change of microdamage in the materials. Experiment results demonstrated that the CFRP composites and carbon fiber tows were damaged by different damage mechinsms during tensile loading, for the CFRP composites, mainly being in the forms of matrix damage and the debonding between matrix and fibers, while for the carbon fiber tows, mainly being in the forms of fiber fracture. The correlation between the infrared thermographs and the change in the electrical resistance could be regarded as an evidence of the damage mechanisms of the CFRP composites. During three-point-bending loading, the main damage forms were the simultaneity fracture of matrix and fibers firstly, then matrix cracking and the debonding between matrix and fiber were carried out. This results can be shown in Fig. 9(a) and (b). During interlaminar shear loading, the change in the electrical resistance was related to the damage degree of interlaminar structure. Electrical resistance measurement was more sensitive to the damage behaviour of the CFRP composites than the stress/time curve.

  • PDF