Browse > Article
http://dx.doi.org/10.6110/KJACR.2014.26.1.032

Thermal Contact Resistance Measurement of Metal Interface at Cryogenic Temperature  

Kim, Myung Su (Korea Basic Science Institute)
Choi, Yeon Suk (Korea Basic Science Institute)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.26, no.1, 2014 , pp. 32-37 More about this Journal
Abstract
The thermal contact resistance (TCR) is one of the important resistance components in cryogenic systems. Cryogenic measurement devices using a cryocooler can be affected by TCR because the device has to consist of several metal components that are in contact with each other for heat transfer to the specimen without a cryogen. Therefore, accurate measurement and understanding of TCR is necessary for the design of cryogenic measurement devices using a cryocooler. The TCR occurs at the interface between metals and it can be affected by variable factors, such as the roughness of the metal surface, the contact area and the contact pressure. In this study, we designed a TCR measurement system at variable temperature using a cryocooler as a heat sink. Copper was selected as a specimen in the experiment because it is widely used as a heat transfer medium in cryogenic measurement devices. We measured the TCR between Cu and Cu for various temperatures and contact pressures. The effect of the interfacial materials on the TCR was also investigated.
Keywords
Thermal contact resistance; Interfacial material; Cryogenic;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Fujishiro, H., Okamoto, T., and Hirose, K., 2001, Thermal Contact Resistance between High-TC Superconductor and Copper, Physica C, Vol. 357-360, pp. 785-788.   DOI
2 Fieberg, C. and Kneer, R., 2008, Determination of thermal contact resistance form transient temperature measurements, International Journal of Heat and Mass Transfer, Vol. 51, pp. 1017-1023.   DOI
3 Bi, D., Chen, H., and Tian, Y., 2012, Influences of temperature and contact pressure on thermal contact resistance at interfaces at cryogenic temperatures, Cryogenics, Vol. 52, pp. 403-409.   DOI
4 Baba, T. and Ono, A., 2001, Improvement of laser flash method to reduce uncertainly in thermal diffusivity measurements, Measurement Science and Technology, Vol. 12, pp. 2046-2057.   DOI
5 Yu, J., Yee, A. L., and Schwall, R. E., 1992, Thermal conductance of Cu/Cu and Cu/Si interfaces from 85 K to 300 K, Cryogenics, Vol. 32, pp. 610-615.   DOI   ScienceOn
6 Xu, R., Feng, H., Zhao, L., and Xu, L., 2006, Experimental investigation of thermal contact conductance at low temperature based on fractal description, International Communications in Heat and Transfer, Vol. 33, pp. 811-818.   DOI
7 Yeh, C. L., Wen, C. Y., Chens, Y. F., Yeh, S. H., and Wu, C. H., 2001, An experimental investigation of thermal contact conductance across bolted joint, Experimental Thermal and Fluid Science, Vol. 25, pp. 349-357.   DOI
8 Rosochowska, M., Balendra, R., and Chodnikiewicz, K., 2003, Measurements of thermal contact conductance, Journal of Materials Processing Technology, Vol. 135, pp. 204-210.   DOI
9 Sarte, V. and Lallenmand, M., 2001, Enhancement of thermal contact conductance for electronic systems, Applied Thermal Engineering, Vol. 21, pp. 221-225.   DOI
10 Juvinall, R. C., 1991, Fundamentals of Machine Component Design, John Wiley and Sons, INC., New York, USA.
11 Gmelin, E., Asen-Palmer, M., Reuther, M., and Villar, R., 1999, Thermal boundary resistance of mechanical contacts between solids at sub-ambient temperature, J Phys D : Appl. Phys, Vol. 32, pp. 19-43.   DOI
12 Incropera, F. P. and Dewitt, D. P., 1996, Fundamentals of Heat and transfer, John Wiley and Sons, INC., New York, USA.