• Title/Summary/Keyword: measurement index

Search Result 2,181, Processing Time 0.03 seconds

Thermal characteristics of high-temperature measurement sensor using fiber Bragg grating (FBG를 이용한 고온 측정 센서의 온도특성)

  • Son, Yong-Hwan;Han, Sang-Kook
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.261-266
    • /
    • 2008
  • In this paper, we present thermal characteristics of high-temperature measurement sensor using fiber Bragg grating(FBG), including peak reflectivity, FWHM bandwidth and various normalized refractive index change along temperature variation. The temperature stability of FBG temperature sensor can be changed by varying the refractive index change and grating length. The proposed FBG temperature sensor can measure up to about $600^{\circ}C$ and 1000 hours of heating time.

Articulation Index for the Evaluation of an Automotive Tire Noise (타이어 소음평가를 위한 명료도 지수)

  • Lee, Tae-Keun;Kim, Byoung-Sam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.203-206
    • /
    • 2009
  • Articulation Index(AI) is the one of the evaluating methods for the interior sound of the automobiles. The AI measures the articulation level of the sound in the vehicle cabin as passengers talk to another. In this study, the effects of AI were investigated according to the various structures of tire. As the structures of tire were changed, the road noise of the vehicle tire was measured using objective measurement. From this measurement data, the AI was calculated. The AI of front is larger than that of rear. Increasing the tread hardness of tire or decreasing the apex height the AI is improved.

  • PDF

Performance Improvement of α-β Tracking Filter using Approximate α-β Gain Updates (근사적 α-β 이득 갱신을 이용한 α-β 추적필터의 성능개선)

  • Kim, Byung-Doo;Lee, Ja-Sung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.12
    • /
    • pp.1256-1260
    • /
    • 2006
  • This paper presents an enhanced ${\alpha}-{\beta}$ tracking filter whose ${\alpha}-{\beta}$ gains are updated by an approximation method at every scan to account for the transition of measurement dependent observation error variance in two-dimensional Cartesian coordinates. The approximate ${\alpha}-{\beta}$ gains are calculated from the amount of the change in the tracking index and the partial derivatives of the ${\alpha}-{\beta}$ gains with respect to a nominal tracking index. It is shown via simulation that the proposed tracker provides improved performance compared to the conventional ${\alpha}-{\beta}$ tracking filter.

A Study for the Measurement System Assessment (측정시스템 평가에 관한 연구)

  • 백재욱
    • Journal of Korean Society for Quality Management
    • /
    • v.26 no.4
    • /
    • pp.124-142
    • /
    • 1998
  • It is essential to have a correct measurement system assessment to help improve process or quality. In this paper, we emphasize that a confidence interval a, pp.oach for the parameters of measurement error study and GR&R is crucial and a simple a, pp.oach for constructing them is presented. We also discuss on the issue of linearity of the gauge. Next, we try to reveal the relationship between measurement error and the process capability index. Finally some aspects of conducting the measuring experiment concerning the number of parts, number of measurements per part, and recommendations on how the experiment is to be performed will be considered.

  • PDF

A Comparative Study on the Measurement of Korean Adult Hand for Glove Pattern-Making (장갑 설계를 위한 한국인 성인 남녀의 손 계측 비교)

  • Suh Mi-A;Ryu Kyung-Ok
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.6 s.53
    • /
    • pp.897-907
    • /
    • 2004
  • The aim of this study is provide fundamental data on the glove size and pattern-making. The study was conducted targeting 60 men and 271 women whose age were within the limits 18-35 in Seoul and the neighboring districts. A total of 90 features in the right hand wew used for the anthropometric measurement and analysis using anthropometry and photometry. The result show that there was a difference between men and women' hand. And the result of correlation analysis between hand factors, length factor related to length and depth factors, breadth factor related to breadth and circumference factors. The sailing glove size in Korea was not suitable to Index finger circumference at 1st Phalanx and Middle finger length.

  • PDF

An Intercity Compararive Study of Qual ity of Life in Korea : A Mulit-Year$\cdot$Mulit-Dimensional Diatance Index Model Approach (다년도$\cdot$다차원 거리지표 모형을 이용한 한국 도시의 삶의 질 비교연구)

  • 김재홍;이은우;이재기
    • Journal of the Korean Regional Science Association
    • /
    • v.14 no.1
    • /
    • pp.21-45
    • /
    • 1998
  • Urban quality of life(QOL) is recently considered as the important determinant of inter-urban migration and industrial location chice. However, there is little concensus in the method of measurement of QOL. This study provides an theoretical framework of the measurement of QOL. This study provides an theoretical framework of the measurement of QOL, and developes a new method, a multi-year$\cdot$mulit-dimensional distance index model. Based on the theoretical framework and the method, the QOLs of 74 urban areas in Korea are measured, and the determinants of the QOL and the changes of the QOL between two years of 1993 and 1995 are analyzed. The results of the analysis are as follows: 1) The interurban differences of the QOL tens to be interban differences of the QOL tend to be intensified over time. 2) The OQLs of the cities in the Capital Region are relatively deteriorated. 3) The conditions of education$\cdot$Culture$\cdot$leisure life determiner over 65% of the QOL of the Korean cities.

  • PDF

A hybrid evaluation of information entropy meta-heuristic model and unascertained measurement theory for tennis motion tracking

  • Zhong, Yongfeng;Liang, Xiaojun
    • Advances in nano research
    • /
    • v.12 no.3
    • /
    • pp.263-279
    • /
    • 2022
  • In this research, the physical education training quality was investigated using the entropy model to compute variance associated with a random value (a strong tool). The entropy and undefined estimation principles are used to extract the greatest entropy of information dependent on the index system. In the study of tennis motion tracking from a dynamic viewpoint, such stages are utilized to improve the perception of the players' achievement (Lv et al. 2020). Six female tennis players served on the right side (50 cm from the T point). The initial flat serve from T point was the movement under consideration, and the entropy was utilized to weigh all indications. As a result, a multi-index measurement vector is stabilized, followed by the confidence level to determine the structural plane establishment range. As a result, the use of the unascertained measuring technique of information entropy showed an excellent approach to assessing athlete performance more accurately than traditional ways, enabling coaches and athletes to enhance their movements successfully.

A Comparative Study on the Measurement Model of Anti-Corruption Index : Anti-Corruption Index and CCEJ's Corruption Index (부패지수 측정모형에 대한 비교연구 : 서울시 시정청렴성지수 측정모형과 경실련 부패지수 측정모형을 중심으로)

  • Park, Yong-Chie;Lee, Chung-Min
    • Survey Research
    • /
    • v.6 no.1
    • /
    • pp.1-38
    • /
    • 2005
  • Considering the importance of corruption index measurement model and the diffusion of popular awareness about the importance of anti-corruption, this research compared and analyzed existing corruption index measurement models. This paper has selected "Anti-Corruption Index model(ACI model)" that was developed by Seoul Development Institute and "CCEJ's Corruption Index model" which is under use by the Citizens' Coaltion for Economic Justice. These two models were analyzed in terms of appropriateness of 'the indicator and index choice method', 'the research design' and 'the use of statistical data'. This analysis shows that two models have some problems. First, at the level of indicator and index choice method, the indicators of CCEJ's corruption index model is too atomized and redundant. As not putting weight of indicator, it did not consider importance of each indicator. Citizens who evaluated the level of corruption didn't participate in the weight evaluation team, which results in failure of the model to reflect the citizens' opinion. Also, because the question about Seoul Metropolis' corruption level is not included, it is not detected difference between real corruption level and perceptive corruption level. Second, in terms of appropriateness of research design, the sample of the CCEJ' corruption index model is too small to get credibility. The objectivity of research method seems to be low because survey was performed by exit interview. In addition, 38 items are overfull in the questionnire of CCEJ's corruption index model compare to 13 items in ACI model. Also, in making up questions, the terms are redundant and unobvious. Third, in regarding with feasibility of the statistical data, the CCEJ's corruption index model uses regulation data for disciplinary punishment of 25 local governments in Seoul from 1995 to 1999. But, it is common ideas of scholars that statistical data indicates the tip of an iceberg in corruption. So for using a statistical data, it needs a data of enough quantity and has a high level credibility. In addition, objective method of giving weight is not developed. In this point of view, the use of statistical data has some limits. To solve this problem, ① objective data should be included in the indicators, ② various indicators should be developed and ③ a method of giving weight should be improved.

  • PDF

A suggestion of Aortic wall Stiffness Evaluation Technique Independent on Changeable Blood Pressure : Aortic Distensibility Index (변화하는 혈압의 영향을 받지 않는 동맥 벽의 강화도 측정 방법 제안 : 대동맥 확장지수)

  • Seo, Jee-Hye;Choi, Dong-Ho;Wu, Zhuqing;Rienmueller, Rainer;Lee, Jong-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.151-158
    • /
    • 2008
  • To evaluate aortic wall stiffness without influence of different background blood pressure, a new technique was developed and verified. At eight swine descending aortae, volume-pressure measurement was performed using custom-made system. Based on averaged pressure-volume curve, aortic distensibility index was formulated to evaluate aortic wall stiffness regardless of variable blood pressure and aortic size. The variability of aortic distensibility index by pressure change was compared with other parameters for wall stiffness evaluation. Subsequently, the aortic distensibility index was calculated at 100 contrast-enhanced EBCT data sets of normal volunteers in regular health screening program. The measured aortic distensibility index was compared with age, coronary calcium score, and aortic calcium score. Between 50 and 360 mmHg of blood pressure, the coefficient of variance of aortic distensibility index was 22.00% as comparing with 88.99% of classical compliance. Based on age, aortic distensibility index showed correlation coefficient of 0.55, whereas classical compliance showed 0.26. The correlation coefficient with modified aortic calcification was 0.43. Linear regression study revealed statistical significance of correlation coefficients. The aortic distensibility index, the method to evaluate aortic wall stiffness free from variable blood pressure and aortic size, was developed and verified with significant practical feasibility.

Fatty Liver Analysis through Quantitative Measurement Study of Ultrasonography Images (초음파 검사 영상의 정량적인 측정 연구를 통한 지방간 분석)

  • Hye-Ri, Chun;Hyon-Chol, Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.927-934
    • /
    • 2022
  • This study attempted to find out the degree of agreement between ultrasound image findings along with analysis of attenuation index and scatter distribution index values within tissues through quantitative measurement analysis using liver ultrasound images. From August 2022 to October 2022, liver ultrasound was performed on 45 patients who were suspected of having fatty liver and who received a prescription for liver ultrasound. As a result of the study, as a result of analyzing the agreement between the ultrasound image findings and the tissue attenuation index, the Kappa value was 0.82 (p<0.05), showing a very high agreement between the two examination methods. In addition, as a result of the agreement analysis between the ultrasound image findings and the scatter distribution index in the tissue, the Kappa value was 0.642 (p<0.05), showing high agreement between the two examination methods. At the time of fat liver prediction, the use of liver ultrasound findings and quantitative ultrasonography techniques, such as intra-tissue attenuation index and intra-tissue scatter distribution index, may be helpful in determining the degree of progression of fatty liver patients.