• Title/Summary/Keyword: measurement equipment

Search Result 1,685, Processing Time 0.025 seconds

Measures to Improve the Efficiency of the Portable Air Quality Measurement System

  • CHOI, Jong-Sun;CHO, Dong-Myung;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.3
    • /
    • pp.27-41
    • /
    • 2022
  • Purpose: In this study, pollutants generated in industrial areas were measured using a Portable Air Quality Measurement System(PAQMS). This study intends to examine in detail improvement measures and operational capabilities to operate a more efficient PAQMS. Research design, data and methodology: This study compares and analyzes the measurement values of the PAQMS and the measurement values of the national air quality measurement network. It is intended to develop a PAQMS corresponding to the data of the national measurement network by minimizing the errors that occur during comparative measurement and analysis and supplementing and improving the problems that occur during the current equipment calibration. Results: A PAQMS is an essential equipment for faster and more accurate measurement and analysis of pollutants in case of untimely measurement and civil complaints due to Micro Climate(local weather and environmental influences). Currently, there are many atmospheric measurement equipment in Korea, but only equipment for each item is produced and sold. Currently, these devices on the market must satisfy various conditions such as stable power, temperature, and humidity to calculate accurate measurement values. Conclusions: Therefore, there is no equipment that satisfies the conditions for performing detailed measurement in the field where accurate measurement is required. In this study, these field work conditions and contents for stable measurement were mentioned in the text.

Comparison of Emission Characteristics from Euro V Diesel Engine by Standard measurement Cycle in the Construction Equipment (EURO V 대응 건설기계 엔진의 표준시험모드에 따른 배출량 비교)

  • Yu, Seunghun;Joo, Taeheun;Lee, Chang-Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.143-144
    • /
    • 2014
  • The demand of diesel engine on the construction equipment has been rapidly increased because of thermal efficiency and power. But some of the construction equipment is imported from other country, since the their demands are not so large as compared with the other construction equipment. The imported construction equipments will be tested for emission with standard measurement mode. This study was conducted to measure emission characteristics of the construction equipment with changed standard measurement experimentally.

  • PDF

A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment (배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Kim, Jae-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.

Voltage Measurement Accuracy Assessment System for Distribution Equipment of Smart Distribution Network

  • Cho, Jintae;Kwon, Seong-chul;Kim, Jae-Han;Won, Jong-Nam;Cho, Seong-Soo;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1328-1334
    • /
    • 2015
  • A new system for evaluating the voltage management errors of distribution equipment is presented in this paper. The main concept of the new system is to use real distribution live-line voltage to evaluate and correct the voltage measurement data from distribution equipment. This new approach is suitable for a new Distribution Management System (DMS) which has been developed for a distribution power system due to the connection of distributed generation growth. The data from distribution equipment that is installed at distribution lines must be accurate for the performance of the DMS. The proposed system is expected to provide a solution for voltage measurement accuracy assessment for the reliable and efficient operation of the DMS. An experimental study on actual distribution equipment verifies that this voltage measurement accuracy assessment system can assess and calibrate the voltage measurement data from distribution equipment installed at the distribution line.

A Study on an Equipment Performance Measurement System for Effective Bottleneck Management (병목 설비의 개선 활동에 유용한 설비관리 지표체계에 관한 연구)

  • Lee, Min-Ho;Lim, Sung-Mook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.33 no.4
    • /
    • pp.100-113
    • /
    • 2010
  • Manufacturing companies' cost competitiveness with respect to equipment management can be achieved by satisfying additional market demands by their own capacity without purchasing additional equipments. In essence, it can be accomplished by making continuous investigation into bottlenecks and improvement on them. Therefore, equipment performance measure systems should be designed so that they can support manufacturing companies' such endeavors. With the purpose of establishing an effective equipment performance measurement system for detecting and improving bottlenecks, this study (1) suggests some desirable features that such a system should have, (2) evaluates conventional equipment performance measurement systems in terms of their usefulness for the detection and improvement of bottlenecks, and (3) proposes an improved system. We also perform a simulation experiment to demonstrate the limitations of the conventional systems and show how the proposed system can resolve the problems.

A Study for Implementation of Density Measurement Equipment for Asphalt Pavement based on the electromagnetic capacitance

  • Park, Young-Ho;Kim, Gun-Kyun;Nor, Jeong-Keun;Ha, Jae-Kwon
    • International Journal of Contents
    • /
    • v.6 no.4
    • /
    • pp.39-42
    • /
    • 2010
  • In this paper we developed density measurement equipment for Asphalt Pavement based on the electromagnetic capacitance. This kind of Non-Nuclear Density Gauges technology and products is used or studied in USA, Finland, Sweden as standardization of authorized method for pavement density measurement. Effective permitivity of pavement asphalt is characterized in electromagnetic capacitance by the asphalt material, mixed ratio, and harden grade of pavement asphalt. We can get a density value of asphalt by replacing value of electromagnetic capacitance with standard density value and characteristic transformation curve. We are conformed that measurement data according to temperature, humidity, and real field asphalt of our density measurement equipment can be a precise value.

Real-Time Compensation of Errors Caused by the Flux Density Non-uniformity for a Magnetically Suspended Sensitive Gyroscope

  • Chaojun, Xin;Yuanwen, Cai;Yuan, Ren;Yahong, Fan;Yongzhi, Su
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.315-325
    • /
    • 2017
  • Magnetically suspended sensitive gyroscopes (MSSGs) provide an interesting alternative for achieving precious attitude angular measurement. To effectively reduce the measurement error caused by the non-uniformity of the air-gap flux density in a MSSG, this paper proposes a novel compensation method based on measuring and modeling of the air-gap flux density. The angular velocity measurement principle and the structure of the MSSG are described, and then the characteristic of the air-gap flux density has been analyzed in detail. Next, to compensate the flux density distribution error and improve the measurement accuracy of the MSSG, a real-time compensation method based on the online measurement with hall probes is designed. The common issues caused by the non-uniformity of the air-gap flux density can be effectively resolved by the proposed method in high-precision magnetically suspended configurations. Comparative simulation results before and after compensation have verified the effectiveness and superiority of the proposed compensation method.

Equipment Development for Inorganic-Compound Concentration Measurement in a Hydroponic Culture Solution (수경배양액 무기성분농도 측정장치 개발)

  • Heo, Jeong-Wook;Park, Kyeong-Hun;Hong, Seung-Gil;Lee, Jae-Su;Baek, Jeong-Hyun;Park, Jong-Taek;Lee, Seung-Kee
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.4
    • /
    • pp.319-326
    • /
    • 2020
  • BACKGROUND: Measurement equipment was developed for inorganic nutrient concentration inside the hydroponic culture medium with several macro- and micro compositions, and applied for measuring the compositions of conventional medium. METHODS AND RESULTS: Before the equipment development, sonicator and heater were utilized to control temperature around of the module mixing with color reagents and target samples among the inorganic compositions. The measurement module and multi-sampler were also manufactured based on the COMS (Complementary Metal-Oxide Semiconductor) and installed inside the measurement equipment. Concentration of standard solution, value measured by the equipment, standard deviation or measured average value were used for estimating the accuracy and average recall of the equipment. Yamazaki solutions with EC of 0.5, 1.5, and 2.5 dS/m were offered to confirm the equipment accuracy and standard error. CONCLUSION: It was suggested that the developed equipment could be automatically applied for measurement with accuracy of over 96% and standard errors of less than 5% on 12 macro- and micro compositions such as a NO3-N, PO43- or Fe.

O-ring Size Measurement Based on a Small Machine Vision Inspection Equipment (소형 머신 비전 검사 장비에 기반한 O링 치수 측정)

  • Jung, YouSoo;Park, Kil-Houm
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.4
    • /
    • pp.41-52
    • /
    • 2014
  • In this paper, O-ring size measurement algorithm based on a small machine vision inspection equipment which can replace a expensive and large machine vision inspection equipment is presented. The small machine vision inspection equipment acquires a image from a CCD camera shooting a measurement plane which located on a back light and the proposed size measurement algorithm is apply to the image. For improvement of size measurement accuracy, camera lens distortion correction and perspective distortion correction are conducted by software technique. Consider O-ring's shape, ellipse fitting model is applied. In order to increase the reliability of ellipse fitting, RANSAC algorithm is applied.

Measurement of Nonlinear Dielectric Constant (비선형 유전율의 측정)

  • Roh, I.S.;Kang, D.H.;Lee, S.U.;Heo, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1331-1333
    • /
    • 2001
  • In this study a measurement equipment was designed and made for the nonlinear dielectric constants in dielectrics. The determining method of the nonlinear dielectric constants also was proposed. The measurement equipment was consisted of the wave generation part, the high voltage amplifier part, the measurement part and the data acquisition part. In this equipment the measurement control and the data processing could be conducted by computer. In order to determine the nonlinear dielectric constants alternating sign-wave electric fields are applied to dielectrics with different magnitude and the waves of the electric fields and the response from dielectrics are stored in computer memories. The harmonics of dielectric displacement are obtained by the Fourier transformation of these waves. The nonlinear dielectric constants are determined at the relatively low-field region. The experiment for PZT ceramic samples was done by the equipment and the determining method and as the result meaningful data were obtained.

  • PDF