• Title/Summary/Keyword: measurement effect

Search Result 6,938, Processing Time 0.029 seconds

Recuction of the Influence of Background Noise in Sound Insulation Measurement (차음성능 측정에 있어서의 암소음의 영향의 저감 (1))

  • 염성곤;다치바나히데끼
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.495-498
    • /
    • 2004
  • In the sound insulation measurements, the influence of background (extraneous) noise is often serious problem and how to reduce its effect and to improve the signal-to-noise(S/N) ratio is an important theme. As the background noise, such extraneous noises as road traffic noise and machine noise often disturb the measurement. In laboratory measurements on specimens with high sound insulation performances, even the internal noise of the measurement system can become a problem. To improve the signal-to-noise ratio and to improve the measurement accuracy, various kinds of digital signal processing techniques can be applied. In this paper, four kinds of digital signal processing techniques are applied and their effectiveness is examined by a simple sound insulation measurement.

  • PDF

Design and Analysis of a State Feedback Controller for a Chain of Integrators System under Measurement Noise (측정에러가 있는 적분기 시스템에서의 상태 궤환 제어기 설계 및 분석)

  • Youn, Jae-Seung;Choi, Ho-Lim
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.969-974
    • /
    • 2010
  • In this paper, we propose a fault-tolerant controller for compensating measurement noise of feedback sensor. Because control systems operate via feedback sensor's signal, the measurement noise in sensor's signal results in performance degradation or even system failure. Therefore, control systems often demand on compensating measurement noise. Our controller is equipped with a compensator in order to reject or reduce the effect of measurement noise in feedback information. Our proposed method is verified via simulation and experiment for a Ball and Beam system.

Measurement of thermal contact resistance at Cu-Cu interface

  • Kim, Myung Su;Choi, Yeon Suk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.48-51
    • /
    • 2013
  • The thermal contact resistance (TCR) is one of the important components in the cryogenic systems. Especially, cryogenic measurement devices using a cryocooler can be affected by TCR because the systems have to consist of several metal components in contact with each other for heat transferring to the specimen without cryogen. Therefore, accurate measurement and understanding of TCR is necessary for the design of cryogenic measurement device using a cryocooler. The TCR occurs at the interface between metals and it can be affected by variable factors, such as roughness of metal surface, contact area and contact pressure. In this study, we designed TCR measurement system at various temperatures using a cryocooler as a heat sink and used steady state method to measure the TCR between metals. The copper is selected as a specimen in the experiment because it is widely used as a heat transfer medium in the cryogenic measurement devices. The TCR between Cu and Cu is measured for various temperatures and contact pressures. The effect of the interfacial materials on the TCR is also investigated.

Effect of Measurement Error on the Economic Design of Control Charts for Controlling Process Means (측정오차가 공정평균 관리도의 경제적 설계에 미치는 영향)

  • 염창선
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.50
    • /
    • pp.55-63
    • /
    • 1999
  • Past studies on economic control charts for controlling process means assumed that the measures of a quality characteristic do not have measurement error. In practice, however, this assumption is frequently violated. In this paper, the economic design models of three control charts(Xbar control chart, Xbar control chart with warning limits, and CUSUM control chart) for controlling process means are developed on the assumption that the measures can have measurement error. The effects of measurement error on the process control cost and design parameters of three economic control charts are examined. According to the experiments done in this study, when measurement error exists, the economic CUSUM control chart has lower process control cost in comparison with two other control charts. When measurement error becomes larger, both the sample size and the sampling interval increase while the control limits decrease.

  • PDF

Design and Analysis of an Output Feedback Controller for a Chain of Integrators System Compensating Measurement Noise of Feedback Sensor (적분기 시스템에서 센서의 측정에러를 보상하는 출력 궤환 제어기 설계 및 분석)

  • Kim, Hyun-Do;Choi, Ho-Lim
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.4
    • /
    • pp.299-303
    • /
    • 2011
  • In this paper, we propose an output feedback controller for a chain of integrators system compensating measurement noise of feedback sensor. Measurement noise makes feedback signals distorted, and results in performance degradation or even system failure. Therefore, we need to design a robust controller to accommodate the possible measurement noise in the feedback information. Our controller is equipped with a gain-scaling factor to reject or minimize the effect of measurement noise in output feedback information. We give a theoretical analysis of the controlled system and illustrate the improved control performance via an example.

Development of Pressure Control System of Contact Transducer for Measurement of Ultrasonic Nonlinear Parameter

  • Lee, In-Ho;Son, Dae-Soo;Choi, Ik-Hwang;Lee, Tae-Hun;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.6
    • /
    • pp.576-581
    • /
    • 2007
  • Ultrasonic nonlinearity has been considered as a promising method to evaluate the micro damage of material; however, its magnitude is so small that its measurement is not easy. Especially, when we use contact PZT transducer, if the contacting pressure is not kept in constant during the measurement then there exists extraneous fluctuation in the measured nonlinearity caused by the unstable contact condition, In this paper, we developed a pneumatic control system to keep the contacting pressure of transducer in constant during the measurement and analyzed the effect of contacting pressure to the ultrasonic nonlinearity measurement As a result, we found that the pressure of transducer in our measurement system should be greater than 170 kPa to measure the ultrasonic nonlinear parameter in stable with no dependency on the contacting pressure.

Case Study of Coordinate Measurement during Construction of Long-Span Irregular Curved Roof Layers (장경간 비정형 곡면 지붕층의 시공중 좌표 계측 사례 연구)

  • Shim, Hak-Bo;Seok, Won-Kyun;Park, Soon-Jeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.14-15
    • /
    • 2019
  • In this paper, it was tried to prove the possibility and effect of coordinate measurement by using MEP layout equipment at the construction stage, and to propose a method to improve measurement accuracy during construction. For this study, the passenger terminal site, which is a long span structure, was selected and compared with three dimensional CAD drawings and construction measurement results using MEP layout equipment for the precise construction of long-span irregular curved roof layers. As a result, it was found that it is possible to construct three-dimensional curved roof layers using MEP layout equipment through measurement and analysis.

  • PDF

Development of the Handy Non-contact Surface Roughness Measurement Device by using the Optical Fiber Sensor (광섬유센서에 의한 간이 비접촉 표면조도 측정기의 개발)

  • Hong, Jun-Hee
    • 대한공업교육학회지
    • /
    • v.34 no.2
    • /
    • pp.346-362
    • /
    • 2009
  • The purpose of this study was to develop the handy non-contact measurement device of the surface roughness by using the optical fiber sensor. The advantages of fiber optic sensors are high-speed responsibility, non-effect of the magnetic, convenience of the product and high precision. The measurement theory for surface roughness of optical fiber sensor is one to one correspondence between the reflected light intensity based on the surface roughness of the object and the measurement value of previously known for surface roughness. The reflected light intensity was determined using the distance to the surface from the sensor probe and the limit reflection angle based on the surface roughness. Therefore, in this study, the sensor probe was produced for determining the value of surface roughness only using the limit reflection angle based on the surface roughness with the fixed distance from the surface. A prototype measurement system was composed of a transmitting part, a receiving part and a signal processing circuit. The materials of standard measurement which was used in this experiment were SM45C, STS303 and Al60. According to the results of this study, approximation surface roughness formulas which was deduced from the correlation of between the standard surface roughness and the sensing output were verified that they were effect against the surface roughness measurement value of the option sample. And handy optical fiber surface roughness measurement device which was produced by an order was verified that it was effect for measuring of the precision surface roughness.

The Effect of Muscle Relaxation Therapy on Nausea, Vomiting and Anxiety of Children with Chemotherapy (근육이완요법이 항암화학요법을 받는 아동의 오심, 구토 및 불안에 미치는 효과)

  • Jung Kyong Hee
    • Child Health Nursing Research
    • /
    • v.6 no.1
    • /
    • pp.60-68
    • /
    • 2000
  • The purpose of this study is to assess the effect of progressive muscle relaxation therapy on nausea, vomiting and anxiety experienced by children who were histologically diagnosed as malignancy and have received cancer chemotherapy. Twenty subjects with 10 in experimental group and 10 in control group, between the age of 7 to 12 years participated in this study. All subjects were admitted for inpatients chemotherapy at the S hospital between April to August 1998. The methods used for interventional muscle relaxation were both the 16 items of the progressive muscle relaxation therapy developed by Jacobson and the 4 items of the muscle relaxation therapy by Wolpe. The method for assessing nausea, vomiting was the Index of Nausea and Vomiting by Rhodes et al and that for anxiety was State-Trait Anxiety Inventory for Children by Spielberger. The data was analysed by repeated measures ANOVA and Scheffe test using SAS program. The results were as follows : 1. On measurement of nausea, vomiting, in the experimental group, the mean values of the second and the third measurements showed tendency to slightly decrease compared with the first measurement, but there was no statistically significance. And in the control group, there were no significant differences among first measurement, second measurement and third measurement. Also there was no significant difference in the mean values assessing nausea, vomiting between experimental and control group (F=1.33, p=0.2645). 2. The results assessing state anxiety showed, in the experimental group, progressive decrease in mean values at each measurement, while the control group showed no significant differences between the mean values of each measurement. Also there was statistically significant difference in state anxiety measurements between experimental and control group(F=4.36, p=0.05). In conclusion, muscle relaxation therapy for school-aged children with chemotherapy could not be effective to decrease nausea, vomiting, but it could be effective to decrease anxiety.

  • PDF

The effect of the self-measurement frequency levels on SmartCare obesity management (스마트케어 비만관리에서 자가 측정 빈도 수준의 효과)

  • Lee, Chang-Hee;Chang, Byeong-Yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1972-1980
    • /
    • 2015
  • This study's purpose was to analyze the effect of the SmartCare obesity management pilot project, which was conducted between 09 March 2011 and 03 April 2013 in Korea (South). Of 212 subjects who were enrolled in the study, the final analysis was conducted with 147 subjects who completed their weight self-measurements and SmartCare services until the end of a 6-month service period. The self-measurement group for evaluation was classified into 3 groups (Low, Middle, and High) by evenly dividing the monthly average frequency of measurement for 6 months and the evaluation indices were weight, and BMI (Body Mass Index) transmitted from the SmartCare System. The monthly average weight and BMI were decreased more in the High Group than the Middle Group and Low Group (M5: High>Middle>Low), and they are showing statistically significant differences between groups (p< 0.05). In conclusion, analysis of the weight and BMI improvement effect showed a greater improvement effect when the self-measurement frequency level was higher.