Abstract
Ultrasonic nonlinearity has been considered as a promising method to evaluate the micro damage of material; however, its magnitude is so small that its measurement is not easy. Especially, when we use contact PZT transducer, if the contacting pressure is not kept in constant during the measurement then there exists extraneous fluctuation in the measured nonlinearity caused by the unstable contact condition, In this paper, we developed a pneumatic control system to keep the contacting pressure of transducer in constant during the measurement and analyzed the effect of contacting pressure to the ultrasonic nonlinearity measurement As a result, we found that the pressure of transducer in our measurement system should be greater than 170 kPa to measure the ultrasonic nonlinear parameter in stable with no dependency on the contacting pressure.
Keywords
Ultrasonic Nonlinear Parameter; Ultrasonic Transducer; Contacting Pressure; Pneumatic Control;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Jhang, K. Y. (2000) Applications of Nonlinear Ultrasonics to the NDE of Material Degradation, IEEE-UFFC, Vol. 47, No. 3, pp. 540-548   DOI
2 Kawashima, K. (2007) Nondestructive Evaluation and Testing of Engineering Materials with Contact Acoustic Nonlinearity - Harmonic Imaging of Tight Cracks and Microdamages -, Journal of the Japanese Society for Non­Destructive Inspection, Vol. 56, No. 6, pp. 274­279
3 Cracker, M. J. Eds. (1997) Encyclopedia of Acoustics, Vol. 1, Wiley Interscience, John Wiley & Sons, Inc., p. 228
4 Jhang, K. Y. and Kim, K. J. (2001) Early Detection of Micro-Defects(Degradation) by Using Nonlinear Acoustic Effect, Journal of the Korean Society for Nondestructive Testing, Vol. 21, No. 4 pp. 439-445
5 Jhang, K. Y., Ha, J. and Jang, H. S. (2004) Detection of micro-delamination in electronic packaging by using the ultrasonic nonlinearity, Key Engineering Materials, Vol. 270-273, pp. 1761-1766   DOI
6 Na, J. K., Cantrell, J. H. and Yost W. T. (1996) Linear and Nonlinear Ultrasonic Properties of Fatigued 410Cb Stainless Steel, Rev. of Prog. in QNDE, Vol. 15, pp. 1347-1351
7 Berndt, T. P. and Green, R. E. (1998) Feasibility Study of Nonlinear Ultrasonic Technique to Evaluate Adhesive Bonds, Nondestructive Characterization of Material VIII, New York Plenum, pp. 125-131