• 제목/요약/키워드: maximum sensitivity

검색결과 941건 처리시간 0.026초

Cu-Ni 박막 스트레인 게이지를 이용한 다이어프램식 압력 센서-II:압력 센서의 설계 제작의 특성 (Diaphragm-Type Pressure Sensor with Cu-Ni Thin Film Strain Gauges-II : Design Fabrication and Characteristics of a Pressure Sensor)

  • 민남기;전재형;박찬원
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권10호
    • /
    • pp.1022-1028
    • /
    • 1997
  • In this paper we present the construction details and output characteristics of a diaphragm-type pressure sensor with Cu-Ni(53:47) thin-film strain gauges. In order to improve the sensitivity and the temperature compensation two circumferential gauges are placed near the center of the diaphragm and two radial gauges are located near the edge. For all the gauges the relative change in resistance ΔR/R with pressure is of the order 10$^{-3}$ for the maximum pressure. The output is found to be linear over the entire pressure range(0-30kfg/cm$^2$)and the output sensitivity obtained is 1.6mV/V. The maximum nonlinearity observed in output characteristics is 0.35%FS for 5V excitation and the hysteresis is less than 0.1%FS.

  • PDF

$\gamma$선(線)(Ir-192)이 연박(鉛箔)두께의 증감(增減)에 따른 필름감도(感度) 효과(效果) (A Study on Film Sensitive Effect Influenced by ${\gamma}-ray$(Ir-192) Depending on Thickness of Lead Foil)

  • 주광태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제2권1호
    • /
    • pp.95-99
    • /
    • 1979
  • When the ${\gamma}-ray$ of average energy 375KeV emitted by Ir-192 is exposed to each film through lead foil with various thickness, the film sensitivity will be different according to the thickness of lead foil and film type. The results on the study, different density and sensitive ratio appeared depending on exposed time and film type, but was made on the following common points. 1. The effect of film sensitivity by the front lead foil showed rapid increase up to the thickness of more or less 0.03mm, and the thicker lead foil was decreased more in the thickness of about $0.05{\sim}0.09mm$. 2. The effect of film sensitivity by the back lead foil was increased up to around of $0.03{\sim}0.08mm$ thickness, the maximum sensitivity was obtained in the thickness of more than $0.03{\sim}0.08mm$ without any change in the above effect. 3. The sensitivity of front lead foil was higher than that of back lead foil in thin lead foil with about 0.127mm thickness, but the sensitivity of back lead foil was higher than that of front lead foil when thickness became thicker.

  • PDF

민감도 함수의 최대치 제어를 통한 강인제어 (Robust Control via Peak Control of Sensitivity Function)

  • 서상민
    • 제어로봇시스템학회논문지
    • /
    • 제15권11호
    • /
    • pp.1071-1075
    • /
    • 2009
  • This article describes a robust control method by using peak control of a sensitivity function in the state-feedback control systems. This method apparently reduces the peak, and as a result makes closed loop systems more stable. The designed closed loop systems also make the response to an external step disturbance more fast with a lower undershoot. At the conclusion, it is verified that the proposed method enhances robust stability and robust performance to parametric uncertainties through $\mu$-plot.

지역사회 거주 노인의 허약선별도구 타당도 평가 (Validation of Instruments to Classify the Frailty of the Elderly in Community)

  • 이인숙;박영임;박은옥;이순희;정인숙
    • 지역사회간호학회지
    • /
    • 제22권3호
    • /
    • pp.302-314
    • /
    • 2011
  • Purpose: This study aimed to validate instruments to classify the frailty of Korean elderly people in community. Methods: For this study, 632 elders were selected from community-based elderly houses and home visiting registries, and data on frailty were collected using three instruments during November, 2008. The Korean Frail Scale (KFS) was composed of 10 domains with the maximum score of 20. The Edmonton Frail Scale (EFS) had 10 domains with the maximum score of 17. The 25_Japan Frail Scale (25_JFS) was composed of 6 domains with the maximum score of 25. Internal consistency was measured with Cronbach's ${\alpha}$. Sensitivity, specificity and area under the curve (AUC) of ROC were measured to see validity with long.term care insurance grade as a gold standard. Results: The Cronbach's ${\alpha}$ was .72 for KFS, .55 for EFS, and .80 for 25_JFS. Sensitivity, specificity, and AUC were 70.0%, 83.2%, and .83, respectively, at cutting point 10.5 for the KFS, 50.0%, 80.9%, and .66, respectively, at 8.5 for EFS, and 80.0%, 85.9%, and .86, respectively, at 12.5 for 25_JFS. Conclusion: KFS and three JFS showed favorable internal consistency and predictive validity. Further longitudinal studies are recommended to confirm predictive validity.

Instrumentation of a Thermal-Optical Carbon Analyzer and Its Sensitivity in Organic and Elemental Carbon Determination to Analysis Protocols

  • Lim, Ho-Jin;Sung, Su-Hwan;Yi, Sung-Sin;Park, Jun-Hyun
    • 한국환경과학회지
    • /
    • 제21권1호
    • /
    • pp.1-9
    • /
    • 2012
  • A thermal-optical transmittance carbon analyzer has been developed to determine particulate organic (OC) and elemental (EC) carbon. Several analysis factors affecting the sensitivity of OC and EC determination were investigated for the carbon analyzer. Although total carbon (TC) is usually consistent in the determination, OC and EC split is sensitive to adopted analysis protocol. In this study the maximum temperature in oxygen-free He in the analysis was examined as a main cause of the uncertainty. Prior to the sensitivity analysis consistency in OC-EC determination of the carbon analyzer and the uniformity of carbonaceous aerosol loading on a sampled filter were checked to be in acceptable range. EC/TC ratios were slightly decreased with increasing the maximum temperature between $550-800^{\circ}C$. For the increase of maximum temperature from $500^{\circ}C$ to $800^{\circ}C$, the EC/TC ratio was lowered by 4.65-5.61% for TC loading of 13-44 ${\mu}g/cm^2$ with more decrease at higher loading. OC and EC determination was not influenced by trace amount of oxygen in pure He (>99.999%), which is typically used in OC and EC analysis. The facing of sample loaded surface to incident laser beam showed negligible influence in the OC-EC split, but it caused elevated PC fraction in OC for forward facing relative to backward facing.

하도 합류부의 수리학적 특성을 고려한 RMA2 모형 매개변수의 민감도 분석 (Sensitivity Analysis of RMA2 Model Parameter Variation with Hydraulic Characteristics of Stream Junction Area)

  • 안승섭;임동희;서명준;이효정
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.783-793
    • /
    • 2008
  • The purpose of this study is to analyze the sensitivity of the RMA2 model parameters reflecting the flow characteristics of stream junction and thus understand the hydraulic characteristics of the channel confluence flow. This study dealt with the input parameters of the RMA-2 model, a two-dimensional numerical analysis model widely used for researches both at home and abroad. The parameters of the RMA-2 model are roughness coefficient, turbulent diffusion coefficient, Coriolis forces latitude, Density, and mesh size. This study those parameters estimated from actual heavy rainfall, and varied the parameter size by (-)30%${\sim}$+30% to review the characteristics of the flow characteristics of the channel section. Weobserved that when the ratio of the channel width was relatively small, the smaller the approaching angle was, the farther from the junctions became the generating place of the maximum flow velocity, however, when the ratio of the channel width was relatively large, the larger the approaching angle was, the farther the generating place of the maximum flow velocity from the junctions became. In particular, the distance between junctions and the place where the maximum flow velocity generated showed an absolute correlationover 90% of the relative channel width, but an inverse relationwas found when the distance to the place where the flow velocity generated was shortened as relative the channel width between the main channel and tributary increased.

자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향 (Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System)

  • 정민규;성열훈
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.635-642
    • /
    • 2020
  • 본 연구에서는 자동노출제어장치(automatic exposure control, AEC)의 채광창 차폐정도와 농도, 감도가 관전류량과 영상품질에 미치는 영향을 분석하였다. 실험에 사용된 장비는 X선관과 간접방식의 디지털검출기가 일체형인 디지털방사선발생장치(Digital Diagnost, Philips, Netherlands)를 사용하였다. 채광창 차폐정도는 3 mm 두께의 납을 이용하여 0%부터 100%까지 12.5%씩 순차적으로 누적 차폐하여 9단계로 구분하였다. 농도는 제조사에서 제시한 3단계(+2.5, 0, -2.5)와 감도 3단계(S200, S400, S800)를 대상으로 하였다. 관전류량 평가는 관전압을 40 kVp로 고정하고 AEC 조절인자들이 교차한 81가지의 조합조건에서 자동 노출된 관전류량을 측정하였다. 영상품질평가는 자체 제작한 원뿔형 피라미드 팬텀의 방사선영상을 육안 평가하여 유효한 영상을 선발하였고 이들의 신호 대 잡음비(signal to noise ratio, SNR)을 측정하였다. 그 결과 관전류량은 채광창 차폐정도가 100%, 감도 S200, 농도 2.5일 때 60.0 mAs로 가장 많이 조사되었으며, 채광창 차폐정도가 0%, 감도 S800, 농도 -2.5일 때 0.9 mAs로 가장 적게 조사되었다. SNR은 채광창 차폐정도가 0%, 감도 S200, 농도 2.5일 때 25.2로 가장 우수하였고, 채광창 차폐정도가 25%, 감도 S800, 농도 -2.5일 때 SNR이 4.7로 가장 낮았다.

민감도 해석을 이용한 동적실속 제어 (Dynamic Stall Control Using Aerodynamic Sensitivity Analysis)

  • 안태술;김형진;김종암;노오현
    • 한국항공우주학회지
    • /
    • 제30권8호
    • /
    • pp.10-20
    • /
    • 2002
  • 본 논문에서는 최적화 방법을 이용하여 동적 실속을 제어하는 방법을 제시하고자 한다. 비정상 공력 민감도 해석코드는 2 방정식 난류 모델을 사용한 비정상 압축성 Navier-Stokes 해석코드로부터 직접 미분법을 사용하여 개발되었다. 목적함수는 해석이 수행되는 전시간에 대한 것보다는 매 순간의 값을 사용하였다. 매 순간의 목적함수에 대한 구배값은 민감도 해석코드를 사용하여 얻었고, 최적화는 매 시간마다 간단한 건형 직선 조사방법(linear line search)을 이용하였다. 제어 변수는 익형의 노즈 반경, 최대 두께와 흡입을 사용하였다. 계산결과는 동적 실속을 제어하는데, 본 논문에서 제시한 최적화 방법이 효과적이라는 것을 보여주고 있다.

Energy absorption characteristics of diamond core columns under axial crushing loads

  • Azad, Nader Vahdat;Ebrahimi, Saeed
    • Steel and Composite Structures
    • /
    • 제21권3호
    • /
    • pp.605-628
    • /
    • 2016
  • The energy absorption characteristics of diamond core sandwich cylindrical columns under axial crushing process depend greatly on the amount of material which participates in the plastic deformation. Both the single-objective and multi-objective optimizations are performed for columns under axial crushing load with core thickness and helix pitch of the honeycomb core as design variables. Models are optimized by multi-objective particle swarm optimization (MOPSO) algorithm to achieve maximum specific energy absorption (SEA) capacity and minimum peak crushing force (PCF). Results show that optimization improves the energy absorption characteristics with constrained and unconstrained peak crashing load. Also, it is concluded that the aluminum tube has a better energy absorption capability rather than steel tube at a certain peak crushing force. The results justify that the interaction effects between the honeycomb and column walls greatly improve the energy absorption efficiency. A ranking technique for order preference (TOPSIS) is then used to sort the non-dominated solutions by the preference of decision makers. That is, a multi-criteria decision which consists of MOPSO and TOPSIS is presented to find out a compromise solution for decision makers. Furthermore, local and global sensitivity analyses are performed to assess the effect of design variable values on the SEA and PCF functions in design domain. Based on the sensitivity analysis results, it is concluded that for both models, the helix pitch of the honeycomb core has greater effect on the sensitivity of SEA, while, the core thickness has greater effect on the sensitivity of PCF.

A new stability and sensitivity design and diagnosis approach

  • Sari, Ali;Korkmaz, Kasim A.
    • Steel and Composite Structures
    • /
    • 제23권6호
    • /
    • pp.683-690
    • /
    • 2017
  • In the stability and sensitivity design and diagnosis approaches, there are various methodologies available. Bond graph modeling by lumping technique is one of the universal methodologies in methodical analysis used by many researchers in all over the world. The accuracy of the method is validated in different arenas. Bond graphs are a concise, pictorial representation of the energy storage, dissipation and exchange mechanisms of interacting dynamic systems, subsystems and components. This paper proposes a bond graph modeling for distributed parameter systems using lumping techniques. Therefore, a steel frame structure was modeled to analyze employing bond graph modeling of distributed system using lumping technique. In the analytical part, the effectiveness of bond graphs to model this system is demonstrated. The dynamic responses of the system were computed and compared with those computed from the finite element analysis. The calculated maximum deflection time histories were found to be comparable. The sensitivity and the stability of the steel frame structure was also studied in different aspects. Thus, the proposed methodology, with its simplicity, can be used for stability and sensitivity analyses as alternative to finite element method for steel structures. The major value brought in the practical design is the simplicity of the proposed method for steel structures.