• 제목/요약/키워드: maximum effective stress

검색결과 289건 처리시간 0.027초

이중 보강링으로 예압된 냉간압출 금형 설계 (Design of the Prestressed Cold Extrusion Die with Two Stress Rings)

  • 허관도;여홍태;예상돈
    • 한국정밀공학회지
    • /
    • 제17권10호
    • /
    • pp.77-82
    • /
    • 2000
  • The design of the prestressed cold extrusion die with two stress rings has been performed in this study. The cold extrusion has been simulated by the rigid-plastic FEM. The stress analysis of die has been performed for both after shrink fitting and during extrusion by using the elastic FEM and the Lame's equation. According to the variation of interferences and diameter ratios, the maximum effective stress has been evaluated. As results, interferences and diameters were determined by the minimization of the maximum effective stress of die insert. The comparison of the maximum effective stress between the proposed design and the conventional design has been discussed. It was found that the maximum effective stress in the die insert is considerably affected by the stiffness of the first stress ring.

  • PDF

다양한 마이크로쓰레드(Micro thread)의 개수를 가지는 임플란트의 상부구조물 형상과 하중조건에 따른 3차원 유한요소해석을 이용한 하악골의 응력분포에 관한 연구 (Three-dimensional Stress Analysis of Implant Systems with Micro Threads in the Maxillary Bone)

  • 신하식;한종현;이수홍;전흥재
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.179-186
    • /
    • 2005
  • A comparative study of stress distributions in the maxillary bone with three different types of abutment was conducted. Finite element analysis was adopted to determine stress generated in the bone with the different implant systems with micro threads (Onebody type implant, Internal type implant, and External type implant). It was found that the types of abutments and the number of micro threads have significant influence on the stress distribution in the maxillary bone. They were due to the difference in the load transfer mechanism and the size of contact area between abutment and fixture. Also the maximum effective stress in the maxillary bone was increased with increasing inclination angle of load. It was concluded that the maximum effective stress in the bone was the lowest by the internal implant among the maximum effective stresses by other two types of implants and by appropriate number of micro threads, and that the specific number of micro thread was existed to decrease the maximum effective stress in the maxillary bone due to different implant systems and loading conditions.

탄성유체 윤활상태와 접선하중을 고려한 접촉표면 내부의 응력해석 (Subsurface Stress Analysis with the Consideration of Tangential Loading and Elasto-Hydrodynamic Lubrication)

  • 구영필
    • Tribology and Lubricants
    • /
    • 제20권4호
    • /
    • pp.190-196
    • /
    • 2004
  • The effect of tangential loading on the subsurface stress field has been investigated numerically. As tangential load increases, the subsurface stress field expands more widely to the direction of the tangential load. Places of the maximum shear stress and the maximum effective stress are getting closer to the surface with the increasing tangential load. The tangential load in an elasto-hydrodynamic lubrication condition is so low that it does not affect the subsurface stress field.

치면 프로파일 모델에 따른 기어 치면 내부의 응력 분포 (Sub­surface Stress Distribution beneath the Contact Surface of the Gear Teeth for Two Profile Models)

  • 구영필;오명석;김형자;김영대
    • Tribology and Lubricants
    • /
    • 제19권6호
    • /
    • pp.357-364
    • /
    • 2003
  • The sub­surface stress field beneath the gear's contact surface caused by the contact pressure in lubricated condition has been calculated. To evaluate the influence of the clearance shape on the stress field, two kinds of tooth profile models were chosen. One is the conventional cylinder contact model and the other is the new numerical model. Love's rectangular patch solution was used to obtain the sub­surface stress field. The analysis results show that the sub­surface stress is quite dependent on both the contact pressure and the profile model. The maximum effective stress of the new model is lower than that of the old model. The depth where the maximum effective stress occurs in the new model is not proportional to the intensity of the external load.

Sub-surface Stress Analysis on Spur Gear Teeth in the EHL Conditions

  • Koo, Young-Pil;Kim, Tae-Wan;Cho, Yong-Joo
    • KSTLE International Journal
    • /
    • 제5권1호
    • /
    • pp.14-22
    • /
    • 2004
  • The sub-surface stress field beneath the gear's contact surface caused by the surface pressure in lubricated condition is analyzed. To evaluate the influence of the clearances between a gear tooth and a pinion tooth on the stress field, two kinds of tooth profile models - conventional cylinder contact model and new numerical model - were chosen. Kinematics of the gear is taken into account to obtain the numerical model which is the accurate geometric clearances between a gear tooth and a pinion tooth. Transient elasto-hydrodynamic lubrication (EHL) analysis is performed to get the surface pressure. The sub-stress field is obtained by using Love's rectangular patch solution. The analysis results show that the sub-surface stress is quite dependent on both the surface pressures and the profile models. The maximum effective stress of the new model is lower than that of the old model. The depth where the maximum effective stress occurs in the new model is not proportional to the intensity of the external load.

5083-0 알루미늄合金의 疲勞균열進展 擧動과 균열닫힘에 관한 硏究 (A study of Fatigue Crack Growth Behavior and Crack Closure in 5083-O Aluminum Alloy)

  • 박영조;김정규;김일현
    • 대한기계학회논문집
    • /
    • 제10권2호
    • /
    • pp.208-214
    • /
    • 1986
  • 본 연구에서는 균열 닫힘에 관한 연구의 일환으로 5083-O 알루미늄합금을 사용하고 소규모강복조건하에서 일정진폭하중피로시험을 시행하여 이 재료의 피로균열 진전속도와 균열닫힘에 관하여 검토하였다.

Effective Notch Stress Method for Fatigue Evaluation of Welded Joints in a Steel Bridge Deck

  • Sim, Hyoung-Bo
    • International Journal of Railway
    • /
    • 제5권2호
    • /
    • pp.89-92
    • /
    • 2012
  • Effective notch stress, as an approach to evaluate the local stress at a notch (weld toe or root), is defined as the total stress assuming linear-elastic material behavior. This method can be effectively used to evaluate the fatigue performance of welded joints. In this study, finite element analysis results using the effective notch stress method were correlated with fatigue test results of rib-to-deck welded joints in a steel orthotropic bridge deck. Effective notch stress approach provided a good correlation with the crack pattern observed in the full-scale fatigue test. A higher effective notch stress at the critical weld toe than at the weld root was consistent with the dominant crack pattern observed at the weld toe during testing. The effective notch stress at the toe on the deck plate was about 80% higher than that on the rib; no cracks at the weld toe on the rib in the testing were observed. Maximum effective notch stress at the weld root occurred on the upper side of the root notch, which indicates that cracks are more likely to propagate into the deck plate, not into the weld metal. This is also consistent with the observed crack pattern in which the crack from the root propagated upward into the deck plate. No such crack pattern, propagating into the weld metal, was observed in the testing.

임프란트의 상부구조물 형상과 하중조건에 따른 3차원 유한요소해석을 이용한 하악골의 응력분포에 관한 연구 (THREE-DIMENSIONAL STRESS ANALYSIS OF IMPLANT SYSTEMS IN THE MANDIBULAR BONE WITH VARIOUS ABUTMENT TYPES AND LOADING CONDITIONS)

  • 신하식;전흥재;한종현;이수홍
    • 대한치과보철학회지
    • /
    • 제41권5호
    • /
    • pp.617-625
    • /
    • 2003
  • Statement of problem : There are many studies focused on the effect of shape of futures on stress distribution in the mandibular bone. However, there are no studies focused on the effect of the abutment types on stress distribution in mandibular bone. Purpose : The purpose of this study is to investigate the effect of three different abutment types on the stress distributions in the mandibular bone due to various loads by performing finite element analysis. Material and method : Three different implant systems produced by Warantec (Seoul, Korea), were modeled to study the effect of abutment types on the stress distribution in the mandibular bone. The three implant systems are classified into oneplant (Oneplant, OP-TH-S11.5). internal implant (Inplant, IO-S11.5) and external implant (Hexplant, EH-S11.5). All abutments were made of titanium grade ELI. and all fixtures were made of titanium grade IV. The mandibular bone used in this study is constituted of compact and spongeous bone assumed to be homogeneous, isotropic and linearly elastic. A comparative study of stress distributions in the mandibular bone with three different types of abutment was conducted. Results : It was found that the types of abutments have significant influence on the stress distribution in the mandibular bone. It was due to difference in the load transfer mechanism and the size of contact area between abutment and fixture. Also the maximum effective stress in the mandibular bone was increased with the increase of inclination angle of load. Conclusion : It was concluded that the maximum effective stress in the bone by the internal implant was the lowest among the maximum effective stresses by other two types.

한반도의 날씨 스트레스 지수 NET(Net Effective Temperature) 분포의 특성 (The Spatial and temporal distributions of NET(Net Effective Temperature) with a Function of Temperature, Humidity and Wind Speed in Korea)

  • 허인혜;최영은;권원태
    • 대한지리학회지
    • /
    • 제39권1호
    • /
    • pp.13-26
    • /
    • 2004
  • 본 연구는 상대적 날씨 스트레스 지수로 NET의 적용 가능성을 파악하고자 하였다. 기상청에서 예보하고 있는 기온, 습도, 바람 자료를 이용하여 NET 값의 시공간적 분포 특성을 분석하였다. 여름철 스트레스 지수인 일 최고 NET의 지역별 스트레스 기준값은 바람과 습도보다는 기온의 영향을 받으므로 일 최고 기온의 분포와 유사하다. 겨울철 스트레스 지수인 일 최저 NET의 스트레스 기준값은 산지 지역과 서울 이북 지역에서는 낮은 기온의 영향을. 해안 지역에서는 강한 바람의 영향으로 기준값이 여름철에 비하여 다양하게 나타난다. 스트레스가 강한 날의 발생 빈도는 여름철은 뚜렷한 연변화가 나타나지 않지만, 겨울철에는 1990년대 중반 이후 뚜렷한 증가 경향을 보인다.

Design optimization of the outlet holes for bone crystal growing with bioactive materials in dental implants: Part II. number and shapes

  • Lee, Kangsoo;Kim, Geug Tae;Lee, Yong Keun
    • 한국결정성장학회지
    • /
    • 제23권2호
    • /
    • pp.76-80
    • /
    • 2013
  • For further improvement of osseo-integration of bone crystal with a dental implant, a design optimization study is carried out for various holes inside its body to deliver bioactive materials and the effect of bioactive material injection on the bone crystal growing. When bioactive material is absorbed, the bone crystal can grow into holes, which would increase the strength of implant bonding as well as a surface integration. The stress concentrations near the uppermost outlet holes were reduced with increasing the number of outlet holes. A design improvement in the uppermost outlet was shown to be effective in reducing the stress concentration. For design parameters under consideration in this study, total area of outlet of 6.38 $mm^2$ and maximum stress of 1.114 MPa, which corresponds to type 6-C. It is due to the minimization of maximum stress and total area of outlet. The design of the outlet facing down was more effective in reducing the maximum stress value compared with a horizontal symmetry.