• 제목/요약/키워드: maximum allowable load

검색결과 138건 처리시간 0.022초

벽식 구조체 적용을 위한 구조용단열패널 성능 평가 (Evaluation on Structural Performance of Structural Insulated Panels in Wall Application)

  • 나환선;이현주;이철희;황성욱;조혜진;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제3권2호
    • /
    • pp.19-27
    • /
    • 2012
  • Structural insulated panels, which are structurally performed panels consisting of a plastic insulation bonded between two structural panel facings are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. By now, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to suggest fundamental reports such as racking resistance, axial capacity, transverse load capacity, and lintel load capacity for SIPs. Test results showed that maximum load was 44.3kN, allowable load was 14.7kN for racking resistance, and that maximum load was 137.6kN, allowable load was 37.4kN/m for axial compression capacity. For transverse load capacity, test results showed $10.3kN/m^2$ of maximum load, $3.4kN/m^2$ of allowable load. For lintel load capacity for SIPs dependent to lengths, allowable loads were 20.4kN for 600mm long lintel, 23.9kN for 1,200mm long lintel, 19.3kN for 1,800mm long lintel, and 2,400mm long lintel had 14.1kN of allowable load. In the near future, when the allowable load for wall application is established, SIPs is considered to substitute the existent post-and-lintel construction to bearing wall structure.

벨로우즈형 신축관이음의 휨각도 예측 및 이를 이용한 배관계의 안정성 해석 (Prediction of Bending Angle of Bellows and Stability Analysis of Pipeline Using the Prediction)

  • 손인수
    • 한국산업융합학회 논문집
    • /
    • 제25권5호
    • /
    • pp.827-833
    • /
    • 2022
  • In this study, the prediction of the bending angle for the 350 A bellows-type expansion joints and the structural stability according to the load were determined. The stability of the 2km piping system was predicted by applying the allowable bending angle of the expansion pipe joint obtained from the analysis. The maximum bending angle was calculated through bending analysis of the bellows-type expansion joints, and the maximum bending angle by numerical calculation was about 1.8°, and the maximum bending angle of the bellows obtained by comparing the allowable strength of the material was about 0. 22°. This angle was very stable compared to the allowable bending angle (3°) of the expansion pipe joint regulation. By applying the maximum bending angle, the allowable maximum deflection of the 2 km pipe was about 3.8 m. When the seismic load was considered using regression analysis, the maximum deflection of the 2km pipe was about 142.3mm, and it was confirmed that the bellows-type expansion joints and the deflection were stable compared to the allowable maximum deflection of the pipe system. These research results are expected to present design and analysis guidelines for the construction of piping and the development of bellows systems, and to be used as basic data for systematic research.

사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(IV) - 압축정재하시험 및 양방향재하시험 자료 분석을 통한 매입 PHC말뚝의 장기허용압축하중의 실증 성능 검증 - (Study(IV) on the Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - Field Verification of Long-term Allowable Compressive Load of PHC Piles by Analyzing Pile Load Test Results -)

  • 이원제;김채민;윤도균;최용규
    • 한국지반공학회논문집
    • /
    • 제35권9호
    • /
    • pp.29-36
    • /
    • 2019
  • 직경 500mm 및 직경 600mm PHC말뚝 A종의 파괴 압축하중($P_n$)은 각각 7.7MN 및 10.6MN으로 계산할 수 있었다. 직경 500mm 및 직경 600mm 매입 PHC말뚝 A종에 대한 압축정재하시험 시 말뚝 두부에 재하된 최대 압축하중은 6.9MN 및 8.8MN으로 측정할 수 있었으며 따라서 이 측정하중은 각각 $P_n$의 90% 및 83% 수준이었다. 직경 500mm 및 직경 600mm PHC말뚝 A종의 장기허용압축하중($P_a$)은 각각 1.7MN 및 2.3MN이었다. 모든 사례 매입 PHC말뚝의 양방향재하시험 자료로부터 계산된 지반의 허용지지력은 국내 현행 설계에서 사용하고 있는 극한지지력 산정공식으로 계산한 지반의 허용지지력보다 높은 수준으로 계산되었다. 따라서 매입 PHC말뚝의 설계에서 사용하는 극한지지력 산정공식은 매입 PHC말뚝의 실제 지지력 거동을 모사할 수 있도록 개선하여야 할 것으로 판단되었다.

최대곡률 방법을 이용한 말뚝의 연직지지력 연구 (A Study on the Vertical Bearing Capacity of Pile using the Maximum Curvature Method)

  • 류정수;김석열
    • 한국지반공학회지:지반
    • /
    • 제11권4호
    • /
    • pp.5-12
    • /
    • 1995
  • 말뚝의 재하시험이 연직지지력을 추정하기 위한 다양한 정보를 제공한다 할지라도 시험 말뚝을 극한하중까지 도달하도록 충분히 재하시킨다는 것은 상당히 어려운 일이며, 이와 같이 파괴시까지 재하하지 못한 말뚝의 연직재하시험의 결과로부터 지지력을 추정하는데 있어서 많은 도해적 방법과 수학적 방법이 시도되었다. 파괴하중을 추정하기 위하여 Southwel 연 이론을 기초로 최대곡률을 이용한 해석적 방법이 필자 등에 의하여 발표된 바 있다. 여기서 파괴하중은 Crowther가 정의한 바와 같이 특정한 기준 을 초과하였을 때의 하중으로 정의하였다. 본 논문은 최대곡률 방법에 의한 허용하중을 결정하기 위하여 Davission의 방법 및 DIN 4014의 허용하중과 비교하여 최대곡률 방법의 안전율을 2.5로 제안하였다. 그 결과 파괴시까지 재하하지 못한 연직재하시험의 결과치로부터 말뚝의 연직지지력을 추정 하는데 있어서 최대곡률 방법에 의한 허용하중의 결정은 타당성이 있는 것으로 판단되었다.

  • PDF

구조용단열패널의 정적가력과 반복가력 성능 평가 (Performance Evaluation on Static Loading and Cyclic Loading for Structural Insulated Panels)

  • 나환선;이현주;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제4권1호
    • /
    • pp.33-39
    • /
    • 2013
  • Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. In Korea, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to identify fundamental performance of both monotonic load and quasi static cyclic load for SIPs in shear wall application. Static test results showed that maximum load was 44.3kN, allowable shear load was 6.1kN/m, shear stiffness was 1.23 M N/m, and ductility ratio was 3.6. Cyclic test was conducted by two kinds of specimens : single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, it was recommended that the allowable shear load for panels was at least 6.1kN/m.

국산 간벌 소경재를 이용한 다중접착접합 기둥부재의 압축강도성능 (Compression strength performance of multi-layer glued columns by using square lumbers produced from domestic small diameter logs)

  • 신일중;김윤희;장상식
    • 농업과학연구
    • /
    • 제38권3호
    • /
    • pp.533-540
    • /
    • 2011
  • This study is to develop a mulit-layer glued columns for construction of Korean-style houses by using domestic small diameter logs. Dried small square lumber glued each other to develop a multi-layer glued columns and evaluated its performance of strength. Then, predicted the design load of multi-layer glued columns and make a comparison between actual load and design load of multi-layer glued columns. In the results, allowable load by allowable stress of multi-layer glued columns was measured one-third of actual columns load and prediction load was measured less than 10~30% of the actual load. Therefore, muilt-layer glued member has a standard allowable stress of compressive of 13 MPa (Larix leptolepis) and 19 MPa (Chamaecyparis obtusa) when used as columns. Also, using compression strength of small diameter square logs could calculate maximum loads of multi-layer glued member as column.

압축력을 받는 선체판의 경계조건에 따른 탄소성거동에 관한 연구 (A Study on the Elasto-Plasticity Behaviour of a Ship's Plate under Thrust According to Boundary Condition)

  • 고재용;박주신;박영현
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2003년도 춘계학술발표회
    • /
    • pp.153-158
    • /
    • 2003
  • Design of general steel structure had applied and achieve elastic design concept mainly so far. Because elastic design supposes that whole structure complies with elasticity formula as that achieve via allowable stress of material is concept that calculate stress distribution of construction about action external load and estimate load of when the maximum stress reaches equally with allowable stress that is established beforehand by maximum safety load of the structure. But, absence that compose actuality structure by deal with external load increase small success surrender and structure hardness falls and tell structure in limit state finally on the whole as showing complicated conduct by interference between these breakdown at buckling by compression. Examined closely about conduct of place since initial buckling through carbon vocal cords transformation finite element analysis series (ANSYS) that place mending condition supposes case that is boundary condition in this investigation.

  • PDF

Large deformation modeling of flexible manipulators to determine allowable load

  • Esfandiar, Habib;Korayem, Moharam H.;Haghpanahi, Mohammad
    • Structural Engineering and Mechanics
    • /
    • 제62권5호
    • /
    • pp.619-629
    • /
    • 2017
  • This paper focuses on the study of complete dynamic modeling and maximum dynamic load carrying capacity computation of N-flexible links and N-flexible joints mobile manipulator undergoing large deformation. Nonlinear dynamic analysis relies on the Timoshenko theory of beams. In order to model the system completely and precisely, structural and joint flexibility, nonlinear strain-displacement relationship, payload, and non-holonomic constraints will be considered to. A finite element solution method based on mixed method is applied to model the shear deformation. This procedure is considerably more involved than displacement based element and shear deformation can be readily included without inducing the shear locking in the element. Another goal of this paper is to present a computational procedure for determination of the maximum dynamic load of geometrically nonlinear manipulators with structural and joint flexibility. An effective measure named as Moment-Height Stability (MHS) measure is applied to consider the dynamic stability of a wheeled mobile manipulator. Simulations are performed for mobile base manipulator with two flexible links and joints. The results represent that dynamic stability constraint is sensitive when calculating the maximum carrying load. Furthermore, by changing the trajectory of end effector, allowable load also changes. The effect of torsional spring parameter on the joint deformation is investigated in a parametric sensitivity study. The findings show that, by the increase of torsional stiffness, the behavior of system approaches to a system with rigid joints and allowable load of robot is also enhanced. A comparison is also made between the results obtained from small and large deformation models. Fluctuation range in obtained figures for angular displacement of links and end effector path is bigger for large deformation model. Experimental results are also provided to validate the theoretical model and these have good agreement with the simulated results.

고강력 PET Interlace Yarn 밀도변화가 Pack Style Shock Energy Absorber의 물성에 미치는 영향 (Effect of Density Variation of High Tenacity PET Interlace Yarn on the Physical Properties of Pack Style Shock Energy Absorber)

  • 조진원;권상준;최종덕;김상태;지병철;양성백;염정현
    • 한국염색가공학회지
    • /
    • 제27권2호
    • /
    • pp.132-141
    • /
    • 2015
  • Fall-arrest systems(maximum arrest force and allowable free-fall) have been widely applied to provide a safe stop during fall incidents for various industrial activities. Fabric structure affects on the mechanical properties of shock energy absorber. The object of this study is to perform the basic research for the evaluation of the capacity of fall arrest energy absorber in relation to the different interlace yarn density. In this work, pack style energy absorber was prepared by weaving 10 types(Interlace yarn density used high tenacity PET 1000D : 60, 59, 58, 57, 56, 55, 54, 53, 52, 51). The paper presents the results of theoretical investigations of the performance of adjustable absorber during fall arrest. Dynamic load tests based on the EU fall protection equipment standard(CE : EN355:2002) were conducted. Results showed that the maximum arrest force by dynamic load test of energy absorber was satisfied with global standard(below 6,000N). Also, Maximum allowable free-fall of energy absorber showed below 1.75m.

수치해석 결과 분석을 통한 다양한 말뚝 선단하부의 지반조건에 따른 대구경현장타설말뚝의 지지력 거동에 관한 연구 (A Study on the Bearing Capacitiy behavior of Large-diameter Drilled Shafts According to Various Ground Conditions under Pile Tip through Numerical Analysis Results)

  • 김채민;윤도균;최용규
    • 한국지반공학회논문집
    • /
    • 제37권11호
    • /
    • pp.7-22
    • /
    • 2021
  • 본 연구에서는 현장타설말뚝에서 실시된 양방향말뚝재하시험 자료에 대하여 역해석을 실시하였다. 그리고 실트질 점토, 실트질 모래, 모래질 실트, 모래질 자갈, 풍화암, 연암의 다양한 선단지반에 지지된 대구경 현장타설 말뚝에 대하여 수치해석을 실시하여 지지력을 분석하였다. 지지력 분석은 P-S 방법, Davisson 방법, 25.4mm 허용침하량을 이용하여 산정하였다. 3가지 방법으로 분석한 최소 허용지지력은 19.64MN ~ 24.96MN으로 나타났다. 이때, 선단지지력은 두부재하하중의 2% ~ 12%를 분담하였으며, 주면마찰력은 두부재하하중의 88% ~ 98%를 분담하였다. 선단 지반의 강도가 클수록 허용지지력이 증가하는 것으로 나타났다. 그러나 최대 허용지지력과 최소 허용지지력의 차이는 5.32MN로 선단 지반종류에 따른 허용지지력의 증가는 27%에 불과하였다.