• Title/Summary/Keyword: maximum absorption

Search Result 1,128, Processing Time 0.023 seconds

The characteristics of bending collapse of aluminum/GFRP hybrid tube (알루미늄/GFRP 혼성튜브의 굽힘붕괴 특성)

  • 송민철;이정주
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.84-87
    • /
    • 2000
  • Square tubes used for vehicle structure components have an important role on keeping its stiffness and preserving occupant safety in vehicle collision and rollover in which it experience axial collapse, bending collapse or both. Bending collapse, which absorbs kinetic energy of the impact and retains a survival space for the occupant, is a dominant failure mode in oblique collision and rollover. Thus, in this paper, the bending collapse characteristics such as the maximum bending moment and energy absorption capacity of the square tube replaced by light-weight material were evaluated and presented. The bending test of cantilever tubes which were fabricated with aluminum, GFRP and aluminum/ GFRP hybrid by co-curing process was performed. Then the maximum bending moment and the energy absorption capacity from the moment-angle curve were evaluated. Based on the test results, it was found that aluminum/ GFRP hybrid tube can show better specific energy absorption capacity compared to the pure aluminum or GFRP tube and can convert unstable collapse mode which may occur in pure GFRP tube to stable collapse mode like a aluminum tube in which plastic hinge is developed.

  • PDF

A Study on the Cycling Effects and the Hydrogen Absorption-Desorption Characteristics Of Metal Hydrides (DiNi5-H2 system) (금속수소화물(DiNi5-H2 system)의 수소 흡수-방출 특성과 반복 효과에 관한 연구)

  • Kim, Youn-Sang;Zhoh, Choon-Koo
    • Applied Chemistry for Engineering
    • /
    • v.1 no.1
    • /
    • pp.30-34
    • /
    • 1990
  • This paper summarizes fundamental research on a metal hydrides for the development of new energy. We made a study of the characteristics of the hydrogen absorption-desorption of $DiNi_5$ alloys. As a result, we found that the maximum amount of the hydrogen absorption of $DiNi_5$ alloys (the maximum in the absorption equilibrium pressure section) was H/M=1.04 at $30^{\circ}C$. The hysteresis was the smallest at $30^{\circ}C$. The capability of the hydrogen absorption-desorption was excellent. The number of cycles of the hydrogen absorption-desorption was about 9000 times at $30^{\circ}C$. We found also that the rate of the hydrogen desorption was the largest at $40^{\circ}C$.

  • PDF

Investigation of Energy Absorption Property of Glass/Epoxy Composite Tubes with Bevel and Tulip Triggers (베벨 및 튤립 트리거를 갖는 유리섬유 복합소재 튜브의 에너지 흡수특성 평가)

  • Kim, Jung Seok
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.4
    • /
    • pp.395-401
    • /
    • 2017
  • Energy absorption capabilities and failure modes of circular tubes made of glass/epoxy with two trigger mechanisms were evaluated. Three types of glass/epoxy tubes were fabricated using a hand lay-up method with unidirectional and woven fabric prepregs tapes, and a filament winding method. The one end of the fabricated tubes was machined for the bevel trigger and tulip trigger. Then, crush tests were conducted at 10 mm/min loading speed, wherein the glass/epoxy tubes were crushed by a brittle fracturing mode combined with fragmentation and lamina-splaying modes. The UD glass/epoxy tubes with a bevel trigger and the filament winded tubes with a tulip trigger showed the maximum and minimum specific energy absorptions, respectively, with a difference of 9.3%. The tube with a tulip trigger exhibited a maximum reduction of 5.7% in the initial peak load; the tube with a bevel trigger showed a maximum increase of 2.9% in the specific energy absorption.

Study on the Optimization of Absorption Performance of the Vertical Tube Absorber with Falling Film (수직 액막형 흡수기의 성능 최적화에 관한 연구)

  • Kim, Jung-Kuk;Cho, Keum-Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.830-838
    • /
    • 2005
  • The present study investigated the optimization of the absorption performance of the vertical absorber tube with falling film by considering heat and mass transfer simultaneously. Effects of film Reynolds number, geometric parameters by insert device (spring) and flow pattern on heat and mass transfer performances have been also investigated. Especially, effects of coolant flow rate and the flow pattern by geometric parameters has been observed for the total heat and mass transfer rates through both numerical and experimental studies. Based on both predicted values, the optimal coolant flow rate was predicted as 1.98 L/min. The maximum absorption rate of the spring inserted tube was increased by the maximum of $20.0\%$ than those for uniform film of bare tube. Average Sherwood numbers and Nusselt numbers were increased as Reynolds numbers increased under the dynamic and geometric conditions showing the maximum absorption performance.

Peak-to-zero modulation of optical absorption via electrically controllable quantum interference

  • Lee, Byoung-Ho;Kim, Kyoung-Youm
    • Journal of the Optical Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.33-36
    • /
    • 2002
  • We propose a modulation scheme of optical absorption in a coupled asymmetric quantum well (QW) structure via electrically controllable quantum interference. It is based on the parallel-perpendicular energy coupling effect. We show that by applying an external electric Held in the parallel direction (to the QW layers), we can obtain a maximum (peak-type) absorption at a specific wavelength where absorption cancellation would occur due to electrically induced transparency without such an external Held .

Pretreatment condition Optimization of Hydrolysis and Water Absorption Behavior of PET Fibrous Assembly (전처리 조건에 따른 PET 섬유 집합체의 가수분해 및 흡수성 거동 연구)

  • Lee, Jun-Hee;Lee, Kwang-Woo;Seo, Mal-Yong;Kang, Ji-Man;Kim, Book-Sung
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.88-88
    • /
    • 2012
  • Applied decanol and nonanol provided more weight loss than applied heptanol and octanol. PET using decanol showed the highest weight loss than other alcohols applied. Sodium hydroxide caused weight loss in PET fabrics because terephthalic acid and ethylene glycol were separated by the hydrolysis of the ester group in the PET chains. The terephthalic acid was neutralized to disodium terephthalate and the reaction results in weight loss in the PET fabrics. The weight loss increased with increasing hydrolysis time because disodium terepthalate was water soluble and the reaction was not reached at equilibrium. Pretreatment alcohols increased water absorption, especially in case of PET applied decanol revealed the highest water absorption. PET applied decanol showed 400% of initial water absorption, and PET applied nonanol revealed 250% of initial water absorption. However, the pristine PET showed 90% initial water absorption, and it revealed 230% maximum water absorption as compared to other alcohols. Also, PET applied decanol, nonanol, octanol and heptanol showed 600%, 400%, 350% and 300% maximum water absorption, respectively. The result implied alcohol length affected on water absorption of PET fibrous assembly. This implies that the microvoid of the PET surface hold water molecules. Surface morphology of PET appears that the pretreatment reagent attacks almost entire surface of the fiber, causing surface etching. As the surface etching progresses, it propagates inside the fiber, resulting in the formation of elongated cavities on the surface.

  • PDF

Study on the Prediction of Absorption Performance by the Optimization of a Vertical Absorber (수직형 흡수기 최적화에 따른 흡수 성능 예측에 관한 연구)

  • Kim, Jung-Kuk;Cho, Keum-Nam
    • Journal of Energy Engineering
    • /
    • v.14 no.3 s.43
    • /
    • pp.194-202
    • /
    • 2005
  • The present study was analytically and experimentally carried out to predict the absorption characteristics on combined heat and mass transfer process in a vertical falling film of variable absorbers. Heat and mass transfer enhancements were analytically investigated. Effects of geometric parameters by insert device (spring) and corrugate, flow pattern on absorption performances has been also investigated. Especially, the optimal values of absorber geometry (ID=22.8mm, L=1150m) and kinetic variables (solution flow rate, flow pattern) for maximum absorption performance has been predicted by the numerical analysis. The maximum absorption performance in a numerical analysis and experiment was shown at the wavy-flow by insert device (spring).

Spectroscopic Studies on the Oxidation of Catechin in Aqueous Solution

  • Bark, Ki-Min;Yeom, Ji-Eun;Yang, Jeong-Im;Yang, Ik-Jun;Park, Chul-Ho;Park, Hyoung-Ryun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3443-3447
    • /
    • 2011
  • The spectroscopic behavior of catechin (5,7,3',4'-tetrahydroxyflavan-3-ol), has been studied in the presence and the absence of air using UV-vis absorption spectrophotometry and fluorescence spectroscopy. The UV-vis absorption spectrum of catechin shows a very sharp and strong absorption maximum peak at 275 nm in deaerated water. New absorption maximum peaks appeared in aerated water, as well as in basic aqueous solution, caused by the oxidation of catechin. The absorbances in the UV-vis absorption spectrum of catechin decreased when the solution was left in the dark for a long time. The fluorescence emission spectrum of catechin after a long time period differs markedly from that in freshly prepared solution; the fluorescence maxia shifted as time passes after adding catechin to the solutions. When the deaerated basic catechin solutions were left in the dark for a long time, their fluorescence quantum yields were found to be nearly zero. This suggests that the oxidized catechin molecules were seen to have slowly undergone successive chemical reactions in basic buffer solution.

Ultrasonic Relaxation for Complexation Reaction Between β-Cyclodextrin and Butanoic Acid in Aqueous Solution (사이크로덱스트린과 부탄산의 복합체 형성반응에 의한 초음파 완화)

  • Bae, Jong-Rim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.100-106
    • /
    • 2012
  • The aim of this work was to reveal the effect of butanoic acid in its dissociated form and undissociated form as a guest molecule on the kinetic parameters in an inclusion reaction with ${\beta}$-cyclodextrin (${\beta}$-CD). Ultrasonic absorption measurements in the frequency range from 0.2 to 45 MHz were carried out for ${\beta}$-CD solutions with butanoic acid at $25^{\circ}C$ by ultrasonic relaxation method. The rate and the equilibrium constants were obtained from the guest concentration dependence of the relaxation frequency, and the standard volume change of the complexation reaction were obtained from the maximum absorption per wavelength. A single relaxational absorption was observed, and the cause of the relaxation was attributed to a perturbation of the chemical equilibrium associated with a complexation reaction between ${\beta}$-CD and butanoic acid. These results were compared with those in solutions containing both ${\beta}$-CD and different guest molecules. It was found that the hydrophobicity of guest molecules played an important role in the formation of the inclusion complex and also that the charge on the carboxylic group had a considerable effect on the kinetic characteristics of the complexation reaction.

A Study on Remodeling for Solar driven $NH_3/H_2O$ absorption chiller (태양열 구동 $NH_3/H_2O$ 흡수식 냉동기 리모델링 연구)

  • Shin, You-Soo;Maeng, Ju-Sung;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.37-43
    • /
    • 2003
  • The aim of this research is to study the feasibility of the solar(hot fluid) driven $NH_3/H_2O$ absorption chiller, made by re-manufacturing of Gas fired $NH_3/H_2O$ absorption chiller. This experimental study is performed with the temperature of the inlet hot fluid of generator. In order to determine the inlet temperature of the generator, which gives maximum COP, the experimental data are obtained with various hot fluid supply temperature in range of $130\sim170^{\circ}C$. Remodeled chiller is operated with periodical cooling effect, which due to mixture subcooled pool boiling, then the COP is evaluated in average. The maximum COP$(\sim0.36)$ is at $160^{\circ}C$. The temperature is stable operation temperature range of typical vacuum collector. It offers a feasibility of solar driven $NH_3/H_2O$ absorption chiller.