• Title/Summary/Keyword: maximum $F_0$

Search Result 1,046, Processing Time 0.025 seconds

Optimization for Phosphorus Remove by Loess Ball Using Chromobacterium (Chromobacterium을 이용한 황토볼에 의한 인산 제거를 위한 최적화)

  • Choi Du Bok;Lee Choon-Boem;Cha Wol-Suk
    • Journal of Life Science
    • /
    • v.15 no.4 s.71
    • /
    • pp.584-589
    • /
    • 2005
  • To investigate factors affecting the removal of phosphorus from the practical wastewater in the F-STEP PROCESS using a loess ball and Chromobacterium WS 2-14, first, the loess ball size and calcining temperature, initial pH, initial phosphorus concentration, working temperature, and aeration were studied. A $2\~4mm$ of loess ball made at $960^{\circ}C$ of calcining temperature was the most suitable one for the removal of phosphorus. When the initial pH was increased from 3.0 to 6.0, the removal efficiency of phosphorus was increased. Especially, at 6.0 of initial pH, the maximum removal efficiency of phosphorus was $88.7\%$. The maximum removal efficiency of phosphorous was gained, 1.8mg/h when the initial concentration of phosphorous was 5.0mg/1. When the operating temperature was $30^{\circ}C$, the maximum removal efficiency of phosphorus was obtained. In the case of aeration, when it was increased from 0.5 to 5.0L/min, the removal efficiency of phosphorus was increased. On the other hand, above 7.0 L/min, the removal efficiency of phosphorus did not increased. Using the optimum operation conditions, pilot tests for the effective removal efficiency of phosphorus were carried out for 65 days. The average removal efficiency of phosphorus was $92.0\%$. The average removal efficiency of COD, BOD, and SS were 77.1, 74.2, and $86.4\%$, respectively. from the results, it can be concluded that F-STEP PROCESS using loess ball might be useful process for phosphorus removal.

THE APPLICATION OF STOCHASTIC ANALYSIS TO COUNTABLE ALLELIC DIFFUSION MODEL

  • Choi, Won
    • Bulletin of the Korean Mathematical Society
    • /
    • v.41 no.2
    • /
    • pp.337-345
    • /
    • 2004
  • In allelic model X = ($\chi_1\chi$_2ㆍㆍㆍ, \chi_d$), M_f(t) = f(p(t)) - ${{\int^t}_0}\;Lf(p(t))ds$ is a P-martingale for diffusion operator L under the certain conditions. In this note, we can show existence and uniqueness of solution for stochastic differential equation and martingale problem associated with mean vector. Also, we examine that if the operator related to this martingale problem is connected with Markov processes under certain circumstance, then this operator must satisfy the maximum principle.

Enhancement of the Early/Precise Diagnosis Based on the Measurement of SUVs in F-18 FDG PET/CT Whole-body Image (F-18 FDG PET/CT 전신 영상에서 SUVs 측정에 기반한 조기/정밀 진단 연구)

  • Park, Jeong-Kyu;Kim, Sung Kyu;Cho, Ihn-Ho;Kong, Eun-Jung;Park, Myeong-Hwan;Cho, Bok-Yeon
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.176-182
    • /
    • 2013
  • Through this research, we measure the data for several SUVs such as SUVLBM, SUVBW, and SUVBSA using volume of interest in order to enhance the diagnostic level in whole-body image for healthy examinees via F-18 FDG PET/CT. Maximum value, mean value, standard deviation, and threshold value for each SUVs are shown. The measurement of SUVs are carried out with 31 examinees who have taken whole-body examination with F-18 FDG PET/CT from July, 2012 to August, 2012. To secure the preciseness of measurement, we selected 26 healthy examinees as a subject of measurement according to diagnostic view of a nuclear-medical doctor. We see from the measurement of SUVs of PET/CT that the value of SUVBW is hightest and followed by SUVLBM and SUVBSA in turn regardless of the use of contrast media. By comparing the SUVLBM-maximum data for the group used contrast media with those for the group used no contrast media, there found a trend that the measured values increase when the contrast media are used. Among them, liver, aorta, lumbar-5, and Cerebellum exhibit significant difference (p<0.05). We conclude that our data for SUVs would be basic references in overall image interpretation, and hope that the research using VOI would be active.

Effect of the LiF anode interfacial layer on polymer light emitting diodes

  • Sohn, Sun-Young;Lee, Dae-Woo;Park, Keun-Hee;Jung, Dong-Geun;Kim, H.M.;Manna, U.;Yi, J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1056-1058
    • /
    • 2005
  • Electrical and optical characteristics of MEH-PPV-based PLEDs with the LiF anode interfacial layer were investigated. The maximum luminance efficiency of the device with a LiF anode interfacial layer of 1-nm-thick was 3.0 lm/W, which is higher than 1.97 lm/W of the device without a LiF layer. By inserting LiF, excess injected holes from ITO anode can be blocked and hence the recombination ratio of electrons and holes can be increased in the emitting layer to improve device efficiency.

  • PDF

WEAR AND CHEMICAL DEGRADATION OF ESTHETIC RESTORATIVE MATERIALS (심미수복 재료의 마모와 화학적 분해)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Hun-Ju;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.190-201
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four esthetic restorative materials in an alkaline solution. The brands studied were Charmfil, Charmfil flow(composite resin), Compoglass F and PrimaFlow(compomer). The results were as follows: 1. The mass loss were not significantly different among the materials(p>0.05). 2. The sequence of the degree of degradation layer depth was in descending order by Compoglass F, PrimaFlow, Charmfil, and Charmfil flow. There were significant differences between Compoglass F and the others(p<0.05). 3. The sequence of the Si loss was in descending order by Charmfil flow, Charmfil, PrimaFlow, and Compoglass F. There were significant differences among these materials(p<0.05). 4. When observed with SEM, destruction of bonding between matrix and filler was observed and when observed with CLSM, the depth of degradation layer of specimen surface was observed. 5. The sequence of maximum wear depth was in descending order by Comfoglass, PrimaFlow Charmal, and Charmfil flow. There were significant differences among these materials(p<0.05). 6. The correlation coefficient between Si loss and degradation layer depth (r=0.602, p<0.05) Vicker's hardness number and maximum wear depth (r=0.501, p<0.05) were relatively high. These results indicate that wear and hydrolytic degradation may be considered to be evaluation factors of composite resins and compomers.

  • PDF

Optimal conditions for biological hydrogen production from food waste

  • Wongthanate, Jaruwan;Chinnacotpong, Kittibodee
    • Environmental Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.121-125
    • /
    • 2015
  • Biohydrogen production from food waste via dark fermentation was conducted by using mixed culture under various environmental conditions (initial pH, initial F/M ratio, initial ferrous iron ($Fe^{2+}$), and temperature condition) in batch reactor. The results revealed that the maximum hydrogen yield of $46.19mL\;H_2/g\;COD_{add}$ was achieved at the optimal conditions (initial pH 8.0, initial F/M ratio 4.0, initial iron concentration 100 mg $FeSO_4/L$ and thermophilic condition ($55{\pm}1^{\circ}C$)). Furthermore, major volatile fatty acid (VFA) productions of butyrate (765.66 mg/L) and acetate (324.69 mg/L) were detected and COD removal efficiency was detected at 66.00%. Therefore, these optimal conditions could be recommended to operate a system.

Numerical Analysis of Magneto-Optic Performance of One-Dimensional Magneto-Photonic Crystal (1차원 자성 포토닉 결정의 자기 광학 특성 수치해석)

  • 박재혁;조재경
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.3
    • /
    • pp.99-105
    • /
    • 2000
  • One dimensional magneto-photonic crystal having structure of (A/B)$^{k/W}$(B/A)$^{k}$ , where M is a magnetic layer of highly Bi-substituted iron garnet, A and B are dielectric layers of $SiO_2$ and T $a_2$O$_{5/}$, and k is the stacking number of the dielectric layers, has been numerically analyzed as a function of the thickness (d$_{M}$) of M (1∼535 nm) and the stacking numer of k (5∼15). The transmittance, Faraday rotation, and figure of merit of the magneto-photonic crystal have been investigated both in the visible and infrared wavelengths. A factor of several and several tens greater Faraday rotation and figure of merit have been obtained compared to the single layer of M, at many localized modes. In the visible the maximum figure of merit of 0.15 was obtained ( = 720 nm) when k = 11 and d$_{M}$ = 375 nm with T : 0.54, $\theta$$_{F}$ = 8.13$^{\circ}$, which was a factor of 30 greater than that of single garnet layer. Much greater maximum figure of merit, 0.285, was obtained in the infrared ( = 1114 nm) when k = 11 and d$_{M}$ = 800 nm with T = 0.66, $\theta$$_{F}$ = 18$^{\circ}$, which was a factor of 100 greater than that of single garnet layer.

  • PDF

The effect of $Co_{3}O_{4}$additives on the magnetic Properties of $Ni_{0.8-xZn_{0.2+x}Fe_{2}O_4}$ ($Co_{3}O_{4}$첨가제 변화에 따른 $Ni_{0.8-xZn_{0.2+x}Fe_{2}O_4}$의 자기적 특성)

  • 이선학;오영우;김덕훈;김현식;이해연;송재성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.331-334
    • /
    • 2001
  • In this study, the magnetic properties for Ni-Zn ferrite were investigated as the function of $Co_3$ $O_4$ additive contents which was predicted to improve the resonance frequency. Toroid specimens with the composition of N $i_{0.8-x}$Z $n_{0.2+x}$F $e_2$ $O_4$(x = 0, 0.05, 0.1, 0.15) ferrites were preparation by conventional ceramic processing technique. The maximum resonance frequency of 19.905 MHz and the permeability of 90.88 in 10 MHz were attained to the N $i_{0.8}$Z $n_{0.2}$F $e_2$ $O_4$with $Co_3$ $O_4$0.3 wt%. Both of the permeability in 10 MHz and the resonance increased to 107.11 and 19.005 MHz respectively for the N $i_{0.8}$Z $n_{0.2}$F $e_2$ $O_4$with $Co_3$ $O_4$wt% than the N $i_{0.8}$Z $n_{0.2}$F $e_2$ $O_4$/ with the free $Co_3$ $O_4$composition.composition.

  • PDF

Prognostic Value of Restaging F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography to Predict 3-Year Post-Recurrence Survival in Patients with Recurrent Gastric Cancer after Curative Resection

  • Sung Hoon Kim;Bong-Il Song;Hae Won Kim;Kyoung Sook Won;Young-Gil Son;Seung Wan Ryu
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.829-837
    • /
    • 2020
  • Objective: The aim of this study was to investigate the prognostic value of the maximum standardized uptake value (SUVmax) measured while restaging with F-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) to predict the 3-year post-recurrence survival (PRS) in patients with recurrent gastric cancer after curative surgical resection. Materials and Methods: In total, 47 patients with recurrent gastric cancer after curative resection who underwent restaging with 18F-FDG PET/CT were included. For the semiquantitative analysis, SUVmax was measured over the visually discernable 18F-FDG-avid recurrent lesions. Cox proportional-hazards regression models were used to predict the 3-year PRS. Differences in 3-year PRS were assessed with the Kaplan-Meier analysis. Results: Thirty-nine of the 47 patients (83%) expired within 3 years after recurrence in the median follow-up period of 30.3 months. In the multivariate analysis, SUVmax (p = 0.012), weight loss (p = 0.025), and neutrophil count (p = 0.006) were significant prognostic factors for 3-year PRS. The Kaplan-Meier curves demonstrated significantly poor 3-year PRS in patients with SUVmax > 5.1 than in those with SUVmax ≤ 5.1 (3-year PRS rate, 3.5% vs. 38.9%, p < 0.001). Conclusion: High SUVmax on restaging with 18F-FDG PET/CT is a poor prognostic factor for 3-year PRS. It may strengthen the role of 18F-FDG PET/CT in further stratifying the prognosis of recurrent gastric cancer.

Emitter-base geometry dependence of electrical performance of AlGaAs/GaAs HBT (에미터와 베이스의 기하구조가 AlGaAs/GaAs HBT의 전기적 특성에 미치는 영향)

  • 박성호;최인훈;최성우;박문평;김영석;이재진;박철순;박형무
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.2
    • /
    • pp.57-65
    • /
    • 1995
  • The effects of device geometry and layout on high speed performance such as current gain outoff frequency(f$_{T}$) and maximum oscillation frequency(f$_{max}$) are of very improtant for the scaling-down of geterojunction bipolar transistors(HBT$_{s}$). In this paper AlGaAs/GaAs HBTs are fabricated by MBE epitaxial growth and conventional mesa process, and the experimental data of emitter-base geometru dependency of HBT performance are presented in order to provide the quantitative information for optimum device structure design. It is shown that f$_{T}$ and f$_{max}$ are inversely proportional to the emiter stripe width, while the low emitter perimeter/area ratio is better to f$_{T}$ and worse ot f$_{max}$. It is also demonstrated the f$_{T}$ and f$_{max}$ are highly improved by the emitter-base spacing reduction resulting in less parsitic effects. As the result f$_{T}$ of 42GHz and f$_{max}$ of 23GHz are obtained for fabricated HBT with emitter area of 3${\times}20^{\mu}m^{2}$ and E-B spacing of 0.2$\mu$m.m.m.

  • PDF