• Title/Summary/Keyword: material factor

Search Result 4,330, Processing Time 0.031 seconds

A Study on the Electrical properties of PSN-PMN-PZI system ceramics modified With $Y_2O_3$and $Fe_2O_3$ ($Y_2O_3$$Fe_2O_3$ 첨가에 따른 PSN-PMN-PZT 세라믹스의 전기적 특성에 따른 연구)

  • 민석규;황상모;이용우;류주현;김종선
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.269-272
    • /
    • 1999
  • In this study, electrical properties and TCFr of Pb(Sb$_{1}$2/Nb$_{1}$2/)O$_3$-Pb(Mn $_{1}$3/Nb$_{2}$3/)O$_3$-Pb(zr, Ti)O$_3$ composition ceramics were investigated wish the Zr/Ti ratio and the additions of Y2O3. and Fe$_2$O$_3$ Electromechanical coupling factor(Kp) showed the highest value of 0.555 in the Zr/Ti=0.50/0.50 ratio ,however, dielectric constant showed the highest value of 1,217 in the Zr/Ti = 0.49/0.51 ratio. Excellent TCFr vague of 421ppm/$^{\circ}C$] at-30~9O$^{\circ}C$ was appeared in the Zr/Ti=0.50/0.50 ratio and electro-mechanical coupling factor(Kp) , mechanical quility factor(Qm) and dielectric constant was 0.496, 1,286 and 1,085 ,respectively ,in the composition ceramics of lwt%Y$_2$O$_3$ and 0.3wt%Fe$_2$O$_3$.

  • PDF

A study on the method of manufacturing $TiO_2$ photoelectrode for improving the photocurrent of dye-sensitized solar cells (염료감응형 태양전지 광전류 향상을 위한 $TiO_2$ 광전극 제작방법에 관한 연구)

  • Baek, Hyung-Ryul;Han, Zhen-Ji;Park, Kyung-Hee;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.354-355
    • /
    • 2006
  • We manufactured photoelectrode of dye-sensitized solar cells (DSC) by using three methods such as squeeze method, spray method, and combination method (squeeze method first, spray method second). We examined how the morphology of an electrode's surface, the pore between particles, and condensation have an effect on an open-circuit voltage, photocurrent, fill factor, and energy conversion efficiency. Open-circuit voltage of dye-sensitized solar cells manufactured by using three methods is about 0.66V when the photoelectrode of the three DSCs is about $5{\mu}m$ thick. Photocurrent and fill factor and conversion efficiency of DSC manufactured by using squeeze method is 18.5 and 34 and 7.8, respectively. Photocurrent and fill factor and conversion efficiency of DSC manufactured by using spray method is 3.62 and 62 and 2.8, respectively. Photocurrent and fill factor and conversion efficiency of DSC manufactured by using combination method is 10.7 and 46 and 5.9, respectively. In conclusion, we find that the combination method is better than the other two methods in such respects as energy conversion efficiency and fill factor.

  • PDF

Transient Response of Functionally Graded Piezoelectric Ceramic with Crack (균열이 있는 기능경사 압전 세라믹의 충격 특성에 관한 연구)

  • Jeong Woo Shin;Tae-Uk Kim;Sung Chan Kim
    • Composites Research
    • /
    • v.16 no.5
    • /
    • pp.21-27
    • /
    • 2003
  • Using the theory of linear piezoelectricity, the dynamic response of a central crack in a functionally graded piezoelectric ceramic under anti-plane shear impact is analyzed. We assume that the properties of the functionally graded piezoelectric material vary continuously along the thickness. By using the Laplace and Fourier transform, the problem is reduced to two pairs of dual integral equations and then into Fredholm integral equations of the second kind. Numerical values on the dynamic stress intensity factors are presented to show the dependence of the gradient of material properties and electric loading.

DEVELOPMENT OF GREEN'S FUNCTION APPROACH CONSIDERING TEMPERATURE-DEPENDENT MATERIAL PROPERTIES AND ITS APPLICATION

  • Ko, Han-Ok;Jhung, Myung Jo;Choi, Jae-Boong
    • Nuclear Engineering and Technology
    • /
    • v.46 no.1
    • /
    • pp.101-108
    • /
    • 2014
  • About 40% of reactors in the world are being operated beyond design life or are approaching the end of their life cycle. During long-term operation, various degradation mechanisms occur. Fatigue caused by alternating operational stresses in terms of temperature or pressure change is an important damage mechanism in continued operation of nuclear power plants. To monitor the fatigue damage of components, Fatigue Monitoring System (FMS) has been installed. Most FMSs have used Green's Function Approach (GFA) to calculate the thermal stresses rapidly. However, if temperature-dependent material properties are used in a detailed FEM, there is a maximum peak stress discrepancy between a conventional GFA and a detailed FEM because constant material properties are used in a conventional method. Therefore, if a conventional method is used in the fatigue evaluation, thermal stresses for various operating cycles may be calculated incorrectly and it may lead to an unreliable estimation. So, in this paper, the modified GFA which can consider temperature-dependent material properties is proposed by using an artificial neural network and weight factor. To verify the proposed method, thermal stresses by the new method are compared with those by FEM. Finally, pros and cons of the new method as well as technical findings from the assessment are discussed.

Crack Analysis of Creep Material Containing Rigid Inclusion with Line Crack Shape (직선 균열 강체 함유물을 내포하는 크?재료의 균열 해석)

  • 이강용;김종성
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.7
    • /
    • pp.91-97
    • /
    • 1998
  • The analysis model is the infinite body consisted of power law creep material containing a rigid inclusion with line crack shape subjected to the arbitrarily directional stress on an infinite boundary. The crack analysis is performed using the complex pseudo-stress function. The strain rate intensity factor is determined in the closed form as new fracture mechanics parmeter which represents the magnitudes of stress and strain rate near the tip in power law creep material.

  • PDF

A Fracture Mechanics Approach on Delamination and Package Crack in Electronic Packaging(l) -Delamination- (반도체패키지에서의 층간박리 및 패키지균열에 대한 파괴역학적 연구 (1) -층간박리-)

  • 박상선;반용운;엄윤용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2139-2157
    • /
    • 1994
  • In order to understand the delamination between leadframe and epoxy molding compound in an electronic packaging of surface mounting type, the stress intensity factor, T-stress and J-integral in fracture mechanics are obtained. The effects of geometry, material properties and molding process temperature on the delamination are investigated taking into account the temperature dependence of the material properties, which simulates as more realistic condition. As the crack length increases the J-integral increases, which suggest that the crack propagates if it starts growing from the small size. The effects of the material properties and molding process temperature on stress intensity factor, T-stress is and J-integral are less significant than the chip size for the practical cases considered here. The T-stress is negative in all eases, which is in agreement with observation that interfacial crack is not kinked until the crack approaches the edge of the leadframe.

Dynamic Stress Intensity Factors of the Half Infinite Crack in the Orthotropic Material Strip with a Large Anisotropic Ratio (이방성비가 큰 직교이방성체의 반 무한 균열에 대한 동적 응력확대계수에 관한 연구)

  • Baek, Un-Cheol;Hwang, Jae-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.6 s.177
    • /
    • pp.1557-1564
    • /
    • 2000
  • When the half infinite crack in the orthotropic material strip with a large anisotropic ratio(E11>>E22) propagates with constant velocity, dynamic stress component $\sigma$y occurre d along the $\chi$ axis is derived by using the Fourier transformation and Wiener-Hopf technique, and the dynamic stress intensity factor is derived. The dynamic stress intensity factor depends on a crack velocity, mechanical properties and specimen hight. The normalized dynamic stress intensity factors approach the maximum values when normalized time(=Cs/a) is about 2. They have the constant values when the normalized time is greater than or equal to about 2, and decrease with increasing a/h(h: specimen hight, a: crack length) and the normalized crack propagation velocity( = c/Cs, Cs: shear wave velocity, c: crack propagation velocity).

A Study on the RF Frequency of Integrated Inductors Array (집적화 인덕터 어레이의 고주파 특성에 관한 연구)

  • Kim, In-Sung;Min, Bok-Ki;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.912-915
    • /
    • 2004
  • Inductors material utilized in the downsizing passive devices and Rf components requires the physical and electrical properties at given area such as inductors thickness reduction, inductance and q-factor increase, low leakage current and thermal stability. In this study, Spiral inductors on the $SiO_2/Si$(100) substrate were fabricated by the magnetron sputtering method. Cu thin film with the thickness of $2{\mu}m$ was deposited on the substrate. Also we fabricated square inductors through the wet chemical etching technique. The inductors are completely specified by the turn width and the spacing between spirals. Both the width and spacing between spirals were varied from 10 to $60{\mu}m$ and from 20 to $70{\mu}m$, respectively. Inductance and Q factor dependent on the RF frequency were investigated to analyze performance of inductor arrays

  • PDF

Re-evaluated Overstrength Factor for Capacity Design of Reinforced Concrete Bridge Columns (철근콘크리트 기둥의 성능설계를 위한 모멘트 초과강도계수에 관한 연구)

  • Lee, Jae-Hoon;Choi, Jin-Ho;Ko, Seong-Hyun;Kwon, Soon-Hong
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.308-315
    • /
    • 2005
  • The capacity protection is normally related with slenderness effect of the columns, force transfer in connections between columns and adjacent elements, and shear design of columns. It is intends to prevent brittle failure of the structural components of bridges, so that the whole bridge system may show ductile behavior and failure during earthquake events. For bridge systems, this means it is necessary to assess the overstrength capacity of columns prior to proceeding with the design of foundation and superstructure. The objective of this paper is to develop a capacity design approach that applies an overstrength factor for determination of possible maximum shear force in the plastic hinge zone of reinforced concrete bridge columns. In order to estimate and determine overstrength factor, material strength was developed to investigate for actual material strength total 3,407 steel and 5,405 concrete by domestic product. Based on actual material strength, this paper was conducted on moment overstrength factors using moment-curvature analysis program. And also design recommendations for capacity design are presented to revise the annual report, KEERC 2002.

  • PDF

A Study on the Crack Growth Behavior of a Inclined Crack in a Non-Uniform Thickness Material (두께가 일정하지 않은 재료에서 경사진 균열의 성장거동에 관한 연구)

  • 조명래;표창률;박종주;고명훈
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.27-38
    • /
    • 1997
  • The effect of geometry factors on the combined mode stress intensity factor behaviors of a slant crack in a non-uniform thickness material was analysed by 2-dimensional theoretical analysis. The analysis is based on the Laurent's series expansions of complex potentials where the complex coefficients of the series are determined from the compatibility and the equilibrium conditions of the thickness interface and the stress free conditions of the crack surface. In numerical calculations the perturbation technique is employed. The expressions for the crack tip stress intensity factor are given in the form of power series of dimensionless crack length $\lamda$, and the function of crack slant angle $\alpha$ and thickness ratio $\beta$. The results of numerical calculations for each problems are represented as the correction factors F($\lamda$, $\alpha$, $\beta$). The results clearly show the following characteristics : The correction factors of the combined mode stress intensity factors for a non-uniform thickness material can be defined in the form of F($\lamda$, $\alpha$, $\beta$). The stress intensity factor values for a given crack length are decreased with increase of thickness ratio $\beta$.

  • PDF