• Title/Summary/Keyword: matching transformer

Search Result 85, Processing Time 0.029 seconds

Magnetic Flux Saturation Analysis of Matching Transformer Considering Characteristic of Dynamic Voltage Restorer(DVR) (DVR의 특성을 고려한 매칭변압기의 자속포화 해석)

  • Shon, Jin-Geun;Kim, Dong-Joon;Kang, Min-Gu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.236-243
    • /
    • 2008
  • This paper analyses magnetic flux saturation of matching transformer considering characteristic of dynamic voltage restorer(DVR) system to solve voltage sags which are considered the dominant disturbances affecting power quality. This DVR consist of PWM inverter to inject arbitrary voltage, LC low pass filter and matching transformer for isolation and grid connection. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core of transformer. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, an advanced modeling method of magnetic flux saturation is used to analyze a magnitude and characteristic of magnetizing current. Simulation and experimental results considering characteristic of DVR system are provided to demonstrate the validity of the proposed analysis method.

The Impedance Matching Network for a ferromagnetic Inductively Coupled Plasma driven at 400 kHz. (400 kHz 페라이트 유도 결합 플라즈마를 위한 임피던스 매칭 네트워크)

  • Cho, Sung-Won;Bang, Jin-Young;Lee, Young-Kwang;Chung, Chin-Wook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.2 s.19
    • /
    • pp.29-33
    • /
    • 2007
  • Low frequency (400 kHz) Ferrite ICP has been proposed for large area processing. Because the coupling coefficient is close to 1, the transformer matching can be adapted to Ferrite ICP. The transformer matching system is simple. In this paper the new matching system by controlling the turns of transformer using relays is proposed for impedance matching. We developed a simple matching system and characterized it when the turns were changed. It was observed that the 2-channel relay is available for transformer matching.

  • PDF

Flux Saturation Modeling of Matching Transformer for Dynamic Voltage Restore (동적전압보상기를 구성하기 위한 정합변압기의 자속포화현상 모델링)

  • Kim Wang-Rae;Kang Ho-Hyun;Jeon Hee-Jong;Han Woon-Dong;Oh Joong-Min
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.428-431
    • /
    • 2006
  • Matching transformer in Dynamic Voltage Compensator is needed for grid connection and isolation. Flux saturation in transformer will be occurred by voltage of transformer from inverter and DC offset voltage and flux saturation makes over current in transformer. In this paper, mathematical modeling of matching transformer is proposed for flux saturation simulation of Dynamic Voltage Compensator.

  • PDF

Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication (고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구)

  • 이재조;유정훈;홍충선;이대영
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.5
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

A Transformer Feedback CMOS LNA for UWB Application

  • Jeon, Ji Yeon;Kim, Sang Gyun;Jung, Seung Hwan;Kim, In Bok;Eo, Yun Seong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.754-759
    • /
    • 2016
  • A transformer feedback low-noise amplifier (LNA) is implemented in a standard $0.18{\mu}m$ CMOS process, which exploits drain-to-gate transformer feedback technique for wideband input matching and operates across entire 3~5 GHz ultra-wideband (UWB). The proposed LNA achieves power gain above 9.5 dB, input return loss less than 15.0 dB, and noise figure below 4.8 dB, while consuming 8.1 mW from a 1.8-V supply. To the authors' knowledge, drain-to-gate transformer feedback for wideband input matching cascode LNA is the first adopted technique for UWB application.

Inrush Current Control of Matching Transformer for Dynamic Voltage Restorer (동적전압보상기를 위한 정합 변압기의 돌입전류 제어)

  • Seo, Il-Dong;Jeon, Hee-Jong;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.340-348
    • /
    • 2006
  • This paper proposes an inrush current control technique of matching transformer for configuration of dynamic voltage restorer(DVR). The DVR system consist of PWM inverter to inject arbitrary voltage, LC low pass filter as harmonic eliminator and matching transformer for isolation. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, the modeling method of magnetic flux saturation is used to analyze a magnitude of inrush current, and additional current controller is used for PWM inverter output regulation. Simulation and experimental results are provided to demonstrate the validity of the proposed control method.

An equivalent Circuit Model of Transformer Coupled Plasma Source (축전 용량이 고려된 평판형 유도 결합 플라즈마 원의 등가회로 모델)

  • Kim, Jeong-Mi;Kwon, D.C.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1760-1762
    • /
    • 2002
  • In this work we develop an equivalent circuit model of TCP(transformer coupled plasma) source and investigate matching characteristic. The developed circuit model includes transmission line, standard-type impedance matching network and displacement current in the plasma source. The impedance of TCP is calculated by previously developed program for various source parameters and dependance of components of matching impedance on the value of source impedance is investigated.

  • PDF

Step-Down Voltage Properties of Piezoelectric Transformer with Extensional Vibration Mode (Extensional 진동 모드를 이용한 압전 트랜스포머의 감압 특성)

  • Choi, Ji-Hyun;Bang, Kyu-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.652-655
    • /
    • 2003
  • In this paper, step-down piezoelectric transformer is studied. The piezoelectric transformer, made of lead zirconate titanate solid solution ceramic, is operated by a fundamental contour-extensional vibration mode. The transformer of 14mm length, 14mm width and 4.5mm thickness was made up two shape(Type I and II). The resonant frequency (fr) is 144kHz and 128kHz at the load resistant of $7.5{\Omega}$ that is a similar to calculating matching impedance. The gain (G) obtained 0.19 and 0.08 at each resonant frequency, when applied input voltage is 25V. The temperature difference with the variation of load resistant was increased with increasing load resistant and was the lowest at $7.5{\Omega}$ near the matching of output impedance.

  • PDF

A Low-Loss On-Chip Transformer Using an Auxiliary Primary Part (APP) for CMOS Power Amplifier Applications

  • Im, Haemin;Park, Changkun
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.403-406
    • /
    • 2019
  • We propose a low-loss on-chip transformer using an auxiliary primary part (APP) for an output matching network for fully integrated CMOS power amplifiers. The APP is designed using a fifth metal layer while the primary and secondary parts are designed using a sixth metal layer with a width smaller than that of the primary and secondary parts of the transformer to minimize the substrate loss and the parasitic capacitance between the primary and secondary parts. By adapting the APP in the on-chip transformer, we obtain an improved maximum available gain value without the need for any additional chip area. The feasibility of the proposed APP structure is successfully verified.

A Study on the Design and Performance of Broad-Band Impedance Matching Transformer (광대역임피던스 정합용변성기의 설계 및 제작에 관한 연구)

  • 조한형;최승철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.13 no.6
    • /
    • pp.501-509
    • /
    • 1988
  • A new type toroidal core transformer for impedance matching for 30MHz~90MHz has been designed and fabricated. It is shown to be reasonably good characteristics that insertind loss was 1.2[dB], VSWR was 1:2.0 and 100[%] bandwidthe was achieved. It is expected that resulting transformer can be used to replace existing frequency selector type matching network because it is much more compact and relatively easy to contruct.

  • PDF