• Title/Summary/Keyword: matching circuit

Search Result 469, Processing Time 0.023 seconds

The Effects of Growth Temperature and Substrate Tilt Angle on GalnP/GaAs Tandem Solar Cells

  • Jun, Dong-Hwan;Kim, Chang-Zoo;Kim, Hog-Young;Shin, Hyun-Beom;Kang, Ho-Kwan;Park, Won-Kyu;Shin, Ki-Soo;Ko, Chul-Gi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.2
    • /
    • pp.91-97
    • /
    • 2009
  • The performance of GaInP/GaAs tandem solar cells with AlInP growth temperatures of 680$^{\circ}C$ and 700 $^{\circ}C$ on n-type GaAs (100) substrate with 2$^{\circ}$ and 6$^{\circ}$ tilt angles has been investigated. The series resistance and open circuit voltage of the fabricated tandem solar cells are affected by the substrate tilt angles and the growth temperatures of the window layer when zinc is doped in the tunnel diode. With carbon doping as a p-type doping source in the tunnel diode and the effort of current matching between top and bottom cells, GaInP/GaAs tandem solar cell has been exhibited 25.58% efficiency.

A Decade-Bandwidth Distributed Power Amplifier MMIC Using 0.25 μm GaN HEMT Technology

  • Shin, Dong-Hwan;Yom, In-Bok;Kim, Dong-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.4
    • /
    • pp.178-180
    • /
    • 2017
  • This study presents a 2-20 GHz monolithic distributed power amplifier (DPA) using a $0.25{\mu}m$ AlGaN/GaN on SiC high electron mobility transistor (HEMT) technology. The gate width of the HEMT was selected after considering the input capacitance of the unit cell that guarantees decade bandwidth. To achieve high output power using small transistors, a 12-stage DPA was designed with a non-uniform drain line impedance to provide optimal output power matching. The maximum operating frequency of the proposed DPA is above 20 GHz, which is higher than those of other DPAs manufactured with the same gate-length process. The measured output power and power-added efficiency of the DPA monolithic microwave integrated circuit (MMIC) are 35.3-38.6 dBm and 11.4%-31%, respectively, for 2-20 GHz.

Design of Planar Power Divider Combiner for K-Band and Improvement of Impedence Matching Condition (K-밴드 평면형 Power Divider / Combiner와 정합특성에 관한 연구)

  • 나극환;홍의석;강준길;김춘길
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.14 no.6
    • /
    • pp.579-589
    • /
    • 1989
  • In this paper, planar power dividers/combiners for millimeter waves K-band or bands which can be printed on the substrates of hybrid or monolithic IC by surface mounting are designed and studied. Power dividers/combiners, and the conductor loss of microstrip lines in particualr the existing Wilkinson power dividers/combiners is modified ad amployes by ist equivalent circuit. Microwave CAD program SUPEROMPACT is employed for the Wilkinson power combiner which is modified and analyzed to reduce the high frequency coupling between the branches of the combiner, and the method to diminish the sensitivity of the input reflection of $2^n$-way power dividers/combiners is studied employing the commerical microwave CAD program package SUPERCOMPACT.

  • PDF

High-speed Performance of Single Flux Quantum Circuits Test Probe (단자속 양자 회로 측정용 고속 프로브의 성능 시험)

  • 김상문;최종현;김영환;강준희;윤기현;최인훈
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.74-79
    • /
    • 2002
  • High-speed probe made to test single flux quantum(SFQ) circuits was comprised of semi-rigid coaxial cables and microstrip lines. The impedance was set at 50 $\Omega$to carry high-speed signals without much loss. To do performance test of high-speed probe, we have attempted to fabricate a test chip which has a coplanar waveguide(CPW) structure. Electromagnetic simulation was done to optimize the dimension of CPW so that the CPW structure has an impedance of 50$\Omega$, matching in impedance with the probe. We also used the simulation to investigate the effect of the width of signal line and the gap between signal line and ground plane to the characteristics of CPW structure. We fabricated the CPW structure with a gold film deposited on Si wafer whose resistivity was above $1.5\times$10$_4$$\Omega$.cm. The magnitudes of S/sub 21/ of CPW at 6 ㎓ in simulations and in the actual measurements done with a network analyzer were: -0.1 ㏈ and -0.33 ㏈ (type A),-0.2 ㏈ and -0.48 ㏈ (type B), respectively. Using the test chip, we have successfully tested the performance of high-speed probe made for SFQ circuits. The probe showed the good performance overthe bandwidth of 10 ㎓.

  • PDF

A New Technique for Suppressing the Sidelobe due to Reflected Wave in the Traveling-Wave Slot Array (진행파 슬롯 배열 안테나에서 반사파에 의한 부엽을 억제하기 위한 새로운 기법)

  • Chae, Bum-Yong;Park, Dong-Hee;Ahn, Bierng-Chearl
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.2
    • /
    • pp.206-211
    • /
    • 2004
  • A new techique is proposed for suppressing sidelobes due to the wave reflected from the waveguide end in the traveling-wave slot array. In this approach we use multiple sections of reduced-height waveguide with the final section terminated with a short circuit instead of the conventional matched load. To show the validity of the proposed method, a Ku-band slotted waveguide is fabricated and tested. Measurements confirm the excellent sidelobe suppressing capability of the proposed method.

Design of Broadband 12 ㎓ Active Frequency Doubler using PHEMT (PHEMT를 이용한 광대역 12 ㎓ 능동 주파수 체배기 설계)

  • 전종환;강성민;최재홍;구경헌
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.6
    • /
    • pp.560-566
    • /
    • 2004
  • In this paper, active frequency doubler with broadband characteristics from 6 ㎓ to 12 ㎓ was designed and fabricated using PHEMT. The designed frequency multiplier has a bias point near pinch-off and a proposed series RC circuit between bias line and input matching network far the improvement of stability. With 0 ㏈m input power, second harmonic of 1.7 ㏈m at 12 ㎓ -27.5 ㏈c suppression of 6 ㎓ fundamental, -18 ㏈c suppression of 18 ㎓ 3rd harmonic, and the 3 ㏈ output bandwidth of 1,8 ㎓ have been measured.

Design and Fabrication of a Convex Array Ultrasonic Transducer with Finite Element Analysis (유한요소 해석법을 이용한 컨벡스 배열형 초음파 탐촉자의 설계 및 제작)

  • Lee, Su-Sung;Kwon, Jae-Hwa;Eun, Hong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.592-599
    • /
    • 2002
  • In this study, an ultrasonic transducer was designed with a commercial finite element analysis (FEA) code, PZFlex, and fabricated based on the design. The transducer has the dimension and shape suitable for abdomen diagnosis working at 5 ㎒ and consists of 128 piezoelectric elements disposed in a convex linear array form. The transducer is composed of two impedance matching layers, one backing layer, and kerfs placed between the piezoelectric elements. Validity of the design with the FEA was illustrated through experimental characterization of a sample transducer. Comparison with the design results by equivalent circuit analysis method was also made to check the superiority of the FEA design.

A Indication Functional Inspection circuit development for Fluorescent ramp end of life (EOL) (형광램프 수명말기 표시기능 검측회로 개발)

  • Hong, Sa-Keun;Choi, Hong-Kyoo;Lee, Guen-Moo;Yoon, Cheol-Gu;Choi, Dae-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.7-11
    • /
    • 2008
  • The fluorescent lamp is one of a discharge lane that is used by electric discharge to transfer from electrical energy to light The fluorescent lamp needs a ballast stabilizer when turn it on because it has negative resistance. Characters of electric discharge and transformed characters of ballast stabilizer are connected closely. Therefore, bring out best design directive that consider economical efficiency and term of a application is very important for both characters matching. In this case, we will team to develop tester and functions for expression for recognizing the end of fluorescent lamp life to solve fire problem and losing efficiency of light when a fluorescent lamp goes the end of the expected its life span.

  • PDF

A EMTP Simulation of High-Voltage Pulse Transformer for Pulsed Power System (펄스파워 시스템용 고전압 펄스변압기의 EMTP 시뮬레이션)

  • Kim, Min-Soo;Lee, Hyong-Gu;Ju, Heung-Jin;Ko, Kwang-Cheol;Kan, Hyong-Bu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1984-1986
    • /
    • 2000
  • In pulsed-power techniques. Marx generator is generally used for the high-power device. but this generator has insulation and spatial problems. So we will suggest a pulse transformer that has a small size to generate the high voltage pulse instead of Marx generator. In this paper, Pulse duration is 4 [${\mu}s$] and the ratio of input and output voltage is 40[kV]/200[kV](step-up ratio=5). The output voltage and the process of pulse compression for pulse circuit are simulated by EMTP (Electro-Magnetic Transient Program). The secondary voltage of pulse transformer is about 200[kV] and pulse width is 4[t/s]. When the secondary winding of the pulse transformer is saturated. the pulse width is 1.25[${\mu}s$]. We selected dummy load 50[$\Omega$] for impedance matching. The pulse voltage of dummy load is 100[kV] and pulse width is 500[ns].

  • PDF

Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system (고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구)

  • Kim, D.H.;Ko, R.K.;Kang, B.M.;Ha, D.W.;Sohn, M.H.;Mun, C.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.