• 제목/요약/키워드: master cast

검색결과 75건 처리시간 0.026초

세 가지 방식으로 제작된 레진코핑의 내면적합성 평가: 3차원적 분석 (Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis)

  • 강신영;박진영;김동연;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the traditional and Digital manufacturing methods through 3-dimensional analysis. Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD). Results: Three groups are measured $47.11{\pm}(3.08){\mu}m$ total RMS of SLAC group, $48.35({\pm}1.55{\mu}m)$ for total RMS of LAPC group, $43.45{\pm}2.09{\mu}m$ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321). Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three-ways methods showed that no differences statistically significant and clinically acceptable results.

전기방전가공법을 이용한 임플랜트 보철물의 적합도 연구 (A STUDY ON THE FIT OF IMPLANT-RETAINED PROSTHESES USING ELECTRIC DISCHARGE MACHINING)

  • 한의택;김영수;김창회;양재호
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.1-13
    • /
    • 2001
  • An absolutely passive fit at the interface with the superstructure and the abutment cylinders is need for implant longevity. In this study, a method of cast framework correction using spark erosion technology was evaluated. Electric discharge machining(EDM) is a process that uses electrical discharges, or sparks, to machine metal, The surface being machined is bombared with high-intensity electrical energy pulses that gradually melt away the stock until the desired configuration is obtained. Master model was fabricated by using metal block impression analogue, which fired 5 Branemark squared impression coping in an arc shaped metal block. Then framework using 4mm standard gold cylinder and type IV gold alloy was fabricated. In order to measure the fit of the framework we used both contact and noncontact coordinate measurement machine and data was processed by computer program. After superimposition of gold framework and master model numeric image data the distances between gold cylinder bearing surfaces and abutment replica bearing surfaces, and the angle deviations between gold cylinder and abutment replica centroid points were calculated. The results were as follows 1 The total mean distance (p<0.01) and standard deviation (p<0.001) between the gold cylinders and abutment bearing surfaces were significantly decreased after EDM 2. The total mean of maximum distances was significantly decreased after EDM (p<0.05). 3. After EDM, the mean angle deviation between centroid points was decreased.

  • PDF

Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study

  • Fattouh, Mohamed;Kenawi, Laila Mohamed Mohamed;Fattouh, Hesham
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.399-406
    • /
    • 2021
  • Purpose: This in vitro study measured and compared 3 intraoral scanners' accuracy (trueness and precision) with different span lengths. Materials and Methods: Three master casts were prepared to simulate 3 different span lengths (fixed partial dentures with 3, 4, and 5 units). Each master cast was scanned once with an E3 lab scanner and 10 times with each of the 3 intraoral scanners (Trios 3, Planmeca Emerald, and Primescan AC). Data were stored as Standard Tessellation Language (STL) files. The differences between measurements were compared 3-dimensionally using metrology software. Data were analyzed using 1-way analysis of variance with post hoc analysis by the Tukey honest significant difference test for trueness and precision. Statistical significance was set at P<0.05. Results: A statistically significant difference was found between the 3 intraoral scanners in trueness and precision (P<0.05). Primescan AC showed the lowest trueness and precision values(36.8 ㎛ and 42.0 ㎛;(39.4 ㎛ and 51.2 ㎛; and 54.9 ㎛ and 52.7 ㎛) followed by Trios 3 (38.9 ㎛ and 53.5 ㎛; 49.9 ㎛ and 59.1 ㎛; and 58.1 ㎛ and 64.5 ㎛) and Planmeca Emerald (60.4 ㎛ and 63.6 ㎛; 61.3 ㎛ and 69.0 ㎛; and 70.8 ㎛ and 74.3 ㎛) for the 3-unit, 4-unit, and 5-unit fixed partial dentures, respectively. Conclusion: Primescan AC had the best trueness and precision, followed by Trios 3 and Planmeca Emerald. Increasing span length reduced the trueness and precession of the 3 scanners; however, their values were within the accepted successful ranges.

아파트 단위세대 공간계획 시 청소년 고려사항에 관한 연구 - 2007년 아파트 현상설계를 중심으로 - (A Study on Youth friendly elements in the Residential Apartments Complex Design - Focused on the Design Competition of Apartment Complex in 2007 -)

  • 김남효;신미옥
    • 한국실내디자인학회논문집
    • /
    • 제18권2호
    • /
    • pp.71-79
    • /
    • 2009
  • It is the youth period that the personality is shaping gradually. The residential environments have influence on the young ego. Especially residential design should include more youth friendly design elements than any other facilities. The purpose of this study was to provide the youth friendly design elements about the space design of apartment through analysis of youth's needs. This study was progressed to the survey method about five districts of apartment design competitions in 2007. The collected cases are analyzed by using statistics software SPSS for windows release 11.0. The result of the study was as below. First, the youth satisfaction of current residential space got more satisfied as floor space got larger. Second, most of youth uses them own room that is satisfied with their floor space for sleeping, inviting friends, studying, playing activities. Third, generally youth preferred to place their own room not far from the restroom, but the result of distance between master room and entrance was classified depend on sex, personal inclination, and residence environment, also generally satisfied with volume of their room. Fourth, for the restroom, although it is too small that satisfied with bath facilities relatively. And cast, youth's preferred room for extra was 'movie/music room', 'game room' and 'dress room' which is higher preference than 'study room'.

고무 인상재의 크기 안정성 및 친수성에 관한 연구 (DIMENSIONAL STABILITY AND WETTABILITY OF RUBBER IMPRESSION MATERIALS)

  • 강충희;방몽숙
    • 대한치과보철학회지
    • /
    • 제30권2호
    • /
    • pp.233-245
    • /
    • 1992
  • The purpose of this study was to evaluate the demensioal stability and wettability of several rubber impression materials. Impressions were made from a metal master die machined to stimulate five full veneer crown preparations symmetrically placed in an arch form. Cast from impressions were measured about ; 1) intrapreparation distance 2) lower base diameter 3) length. For comparing materials were formed against a smooth surface. The advancing contact angle of a saturated aqueous solution of $CaSO_4$ on the impression materials was measured after 1 minute. Mean contact angle were calculated and results were analyzed. Results were as follows : 1. As the intrapreparation distance, hydrophilic addition-cured silicone had the smallest change and condensation-cured silicone had the largest one. 2. As the lower base diameter, traditional addition-cured silicone had the smallest change and polyether had the largest one. 3. As the height, traditional addition-cured silicone had the smallest change and polyether had the largest one. 4. As the contact angle, polyether had the smallest change and condensation-cured silicone had the largest one.

  • PDF

The path of placement of a removable partial denture: a microscope based approach to survey and design

  • Mamoun, John Sami
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.76-84
    • /
    • 2015
  • This article reviews the topic of how to identify and develop a removable partial denture (RPD) path of placement, and provides a literature review of the concept of the RPD path of placement, also known as the path of insertion. An optimal RPD path of placement, guided by mutually parallel guide planes, ensures that the RPD flanges fit intimately over edentulous ridge structures and that the framework fits intimately with guide plane surfaces, which prevents food collecting empty spaces between the intaglio surface of the framework and intraoral surfaces, and ensures that RPD clasps engage adequate numbers of tooth undercuts to ensure RPD retention. The article covers topics such as the causes of obstructions to RPD intra-oral seating, the causes of food collecting empty spaces that may exist around an RPD, and how to identify if a guide plane is parallel with the projected RPD path of placement. The article presents a method of using a surgical operating microscope, or high magnification (6-8x or greater) binocular surgical loupes telescopes, combined with co-axial illumination, to identify a preliminary path of placement for an arch. This preliminary path of placement concept may help to guide a dentist or a dental laboratory technician when surveying a master cast of the arch to develop an RPD path of placement, or in verifying that intra-oral contouring has aligned teeth surfaces optimally with the RPD path of placement. In dentistry, a well-fitting RPD reduces long-term periodontal or structural damage to abutment teeth.

의치상 재이장재의 물리학적 성질에 관한 연구 (AN EXPERIMENTAL STUDY ON THE PHYSICAL PROPERTIES OF DENTURE BASE RELINERS)

  • 권용원;조인호
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.193-202
    • /
    • 1990
  • The purpose of this study was to compare the fithness, hardness and bending strength of the conventional reliners and visible light curing reliner. Nine regions were selected in the upper transverse section which were thought to be of interest from a clinical standpoint and the discrepancies between the dentures and the master cast in these regions were determined by the coordinated measuring machine(UMM-500, Zeiss, W. Germany). The results were as follows ; 1. The experimental denture bases showed the lowest fittness at the central portion of the posterior palatal border and the intimate contact in the buccal flanges regardless of relining materials and relining methods. 2. The fittness of relined denture base was the best in autopolymerizing group and in the order of long processing, short processing and visible light curing group. 3. The fittness after 24 hour-storage in water was improved in long processing and autopolymerizing groups, but there was no significant difference. 4. The hardness was the highest in long processing group and decreased in the order of short processing, visible light curing and autopolymerizing group. 5. The bending strength was the highest in long processing group and decreased short processing, visible light curing, and aotopolymerzing group in order.

  • PDF

치과기공소의 보철 기공물 제작 과정에 사용되는 재료 및 방법에 관한 실태조사 연구 (Descriptive study on the procedure of dental prostheses at the dental laboratory in Seoul)

  • 황경숙
    • 대한치과기공학회지
    • /
    • 제16권1호
    • /
    • pp.57-77
    • /
    • 1994
  • The purpose of this study is to investigate the extent to which dental laboratories use proper materials, procedures, devices, and equipments to fabricate crown & bridge, PFM(Porcelain Fused to Metal) crown & bridge, partial denture, complete denture, and other prosteses. 100 laboratories in Seoul were selected for this investigation. Questionnaires were constructed focusing on five topocs:crown & bridge, PFM crown & bridge, partial denture, complete denture, and other prostheses. The results from this survey were as follows : 1. Most dental laboratories used old, inexpensive, and familiar materials rather than newly developed ones. 2. Most of the dental technicians did not stick to the standard procedures of handling materials, but to their own experiences. 3. Newly developed equipments to fabricate dental prostheses were possessed by nearly 30% dental laboratories. 4. About 80% of dental laboratories were using the procedures they had learned in the school : die trimming for accurate crown margin and softening heat treatment after RPD gold casting. But less than 30% of laboratories were shown to follow the boxing procedure to produce master cast and laboratory remounting in the process of complete denture. The findings show that dental laboratory procedures to fabricate dental prostheses are incomplete and inaccurate in some instances. So, further studies are neededs to clarify the causes of some inaccurate procedures, the better and more equipments should be supplied to produce the more accurate dental posthesis, and more efforts at enancing the appropriate use of dental materials and procedures should be made.

  • PDF

다수 임플란트 지지 보철물에서 지대주 나사의 풀림 토크값에 대한 연구 (Detorque values of abutment screws in a multiple implant-supported prosthesis)

  • 이주리;이동환;황재웅;최정한
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.280-286
    • /
    • 2010
  • 연구 목적: 본 연구는 다수의 임플란트에 의해 지지되는 보철물을, 두 가지 인상법에 의해 얻은 모형들에 연결한 후, 나사의 풀림 토크값을 측정하여 나사 결합부 안정성에 차이가 있는지를 알아보는데 그 목적이 있다. 연구 재료 및 방법: 네 개의 외부 육각 임플란트 (Br${\aa}$nemark $System^{(R)}$; Nobel Biocare AB)에 직접 연결되는 임플란트 상부 구조물과, 이와 수동적 적합을 갖는 완전 무치악 하악주모형을 만들었다. 이 주모형에서 비연결 인상법으로 6회 인상을 채득하여 6개의 모형 (1군)을 제작하고, 아크릴릭 레진을 이용한 연결 인상법으로 6회 인상을 채득하여 6개의 모형 (2군)을 제작하여, 총 12개의 실험모형을 제작하였다. 각 실험모형에 상부 구조물을 지대주 나사 ($TorqTite^{(R)}$ GoldAdapt Abutment Screw; Nobel Biocare AB)로 20 Ncm의 힘으로 조인 후 각 나사의 풀림 토크값을 총 2회 측정하였다. 두 군 간 나사의 풀림 토크값의 비교를 위한 통계분석은 반복측정을 고려하고 나사와 reading을 고정효과로, 모형을 랜덤효과로 포함하는 혼합모형 (mixed model)을 이용하여 유의수준 .05에서 실시하였다. 결과: 나사의 풀림 토크값의 평균은 7.9 Ncm (1군)과 8.1 Ncm (2군)이었으며, 4개 나사의 풀림 토크값 중 최소값인 최소 풀림 토크값의 평균은 6.1 Ncm (1군)과 6.5 Ncm (2군)이었다. 나사의 풀림 토크값은 두 군 간에 통계적으로 유의할 만한 차이가 없었고, 조인 순서와 위치가 서로 다른 4개의 나사 간의 풀림 토크값도 통계적으로 유의한 차이가 없었다. 최소 풀림 토크값도 두 군 간에 통계적으로 유의할 만한 차이가 없었다. 결론: 다수의 외부 육각 임플란트에 의해 지지되는 보철물에서, 나사의 풀림 토크값과 최소 풀림 토크값은 비연결 인상법과 연결 인상법에 의해 얻어진 모형 간에 차이가 없어, 나사 결합부 안정성에 차이가 없는 것으로 판단된다.

수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교 (A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems)

  • 김성준;조광헌;이규복
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.148-155
    • /
    • 2009
  • 연구목적: 최근에는 금속도재관의 심미적 문제로 심미성과 강도가 개선된 코아용 도재 및 지르코니아를 이용한 전부도재관 시스템에 관심이 증가되고 있다. 특히 금속과 유사한 강도를 가지면서 금속의 비심미성을 극복할 수 있는 지르코니아를 이용한 보철물의 제작이 국내외에서 많이 이뤄지고 있다. 하지만 CAD/CAM 시스템으로 제작되는 여러 종류의 지르코니아를 이용한 전부도재관의 적합도에 대한 임상 연구는 부족한 실정이다. 다양한 CAD/CAM 시스템 중 Procera, Cerec inLab, Lava에 의해 제작된 지르코니아를 이용한 전부도재관의 변연 적합도와 내면 적합도를 측정하여 이를 전통적인 방식으로 주조된 금속 도재관의 적합도와 비교 평가해 봄으로써 임상 적용에 참고 자료로 활용하고자 한다. 연구 재료 및 방법: 본 연구를 위해 하악 우측 제2소구치에 해당하는 레진치를 삭제하여 인상채득 후, 금속 주모형을 제작하였다. 금속 주모형의 40개의 인상을 채득 후 각 시스템마다 10개씩 총 40개의 crown을 제작하였다. 금속도재관은 전통적인 방식으로 제작하였고 Procera, Lava, Cerec inLab crown은 zirconia core를 이용하여 CAD/CAM 시스템으로 제작하였다. 수직 변연 오차와 내면 간격을 각 그룹마다 금속 주모형에 시멘트 접착 없이 측정하였다. 그 결과는 oneway ANOVA와 Tukey's HSD test로 통계 내었다. 결과: 수직 변연 오차는 금속도재관이 $50.6{\pm}13.9{\mu}m$, Procera crown이 $62.3{\pm}15.7{\mu}m$, Lava crown이 $45.3{\pm}7.9{\mu}m$, Cerec inLab crown은 $71.2{\pm}2.0{\mu}m$로 측정되었다. 내면 간격은 금속도재관이 $52.6{\pm}10.1{\mu}m$, Procera crown이$161.7{\pm}18.5{\mu}m$, Lava crown이 $63.0{\pm}10.2{\mu}m$, Cerec inLab crown이 $73.7{\pm}10.7{\mu}m$로 측정되었다. 변연 적합도 측면에서 볼 때 Procera crown, Lava crown, Cerec inLab 그리고 전통적인 금속도재관은 임상적으로 받아들일 수 있는 적합도 범위($120{\mu}m$) 내에 있었다. 내면 적합도 측면에서 볼 때 Procera crown을 제외한 Lava crown, Cerec inLab, 금속도재관은 임상적으로 받아들일 수 있는 적합도 범위($140{\mu}m$) 내에 있었다.