• 제목/요약/키워드: master cast

검색결과 75건 처리시간 0.019초

한국인의 상악 유치악 치열 및 무치악 치조제에 관한 삼차원적 연구 (THREE-DIMENSIONAL ANALYSIS OF THE NORMAL DENTITION AND EDENTULOUS MAXILLA OF KOREANS)

  • 김형섭;신상완
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.191-203
    • /
    • 2005
  • Statement of problem. In Korea, the preliminary impression trays for dental and edentulous maxillae are manufactured on the base of the statistical value of Westerners. There had been less study on the dental and edentulous arches of Koreans. Purpose. The purpose of this study was to evaluate an average dental cast, preliminary impression trays, three-dimensional relation of dental and edentulous maxilla of Koreans Material and methods. The subjects for this study were 173 dental casts of maxilla (dental: 52, edentulous : 146) with ages $18\{\sim}60$ years old. Each of the master casts was measured 69 measuring points on the dental cast or maxilla, and 46 measuring points on the edentulous cast of maxilla with three-dimensional digital measuring machine. Each measuring points were analysed and were overlapped, that three dimensional dental graphic manufactured by CAD/CAM system. Results. 1. A standard of distribution to alveolar bone were width between left and right buccal border lines of the standard 3/4 line. The mean value of dental and edentulous casts were 67.27mm, 63.49mm respectively. 2. Morphological classification of dental casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 17%, 16%, 67%, respectively. Dimensional classification of the dental casts were divided into five groups of less than 63mm, 63 up to 65mm, 65 up to 67mm. 67 up to 69mm, more than 69mm, respectively. 3. Morphological classification of edentulous casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 18%, 17%, 65%, respectively Dimensional classification of the edentulous casts were divided into five groups of less than 57mm, 57 up to 61mm, 61 up to 65mm, 65 up to 69mm, more than 69mm, respectively. 4. Mean dental and edentulous cast of maxilla were overlapped, the proportion of bone resorption to alveolar bone is higher than that of palatal bone, its difference were higher anterior 2/4 area than posterior 3/4 area. Conclusion. It obtains information of preliminary impression trays for dental and edentulous maxilla of Koreans.

인상채득 후 경화시 트레이의 위치에 따른 주모형의 변화 (Change master cast by hardening method to position of tray after impression taking)

  • 이정애
    • 한국치위생학회지
    • /
    • 제8권2호
    • /
    • pp.53-66
    • /
    • 2008
  • There was to purpose of this study improves analyzing cause that prosthesis brings bite engaging that is inaccurate in patient's mouth, when supposed that all conducts that do in operatory and dental laboratory are perfect. Impression did check bite by alginate impression material and polymerization style silicon impression material that use usually in presence at a sickbed Irreversibility, hydrocolloid, alginate impression material washed in flowing water and poured anhydrite after wait about 8 minutes so that region that charge interest after impression check bite may become undoing. And hydrophile property addition polymerization style impression material poured anhydrite after blow 30 considering impression material dwell time and H2 gas occurrence time (5~15 minute) after have washed in flowing water. I got each 7 models, result that manufactures total 28 and measures by third dimension measuring instrument (Meteo, Korea) following sequence curing in tray holder and floor 1, By Alginate impression when is hardened in tray holder and when is hardened in the floor after do check bite, SPH 4, SPH5 all as there is synonymy appeared(P<0.05). By in case do not use average 0.1741 in case use tray holder in 0.0447 SPH5s in case do not use average 0.2838 pastas in case use tray holder in SPH4 0.0309, When did not use both SPH4 and SPH5 tray holder, when used tray holder, 1 appeared more greatly. 2. By amity sex addition polymerization style silicon impression when is hardened in tray holder after do check bite and when is hardened in the floor SPH 4, a11 of the SPH5s very big synonymy be(P>0.05). And in case use tray holder in 0.000657 pasta SPH5s in case do not use average 0.000129 pastas in case use tray holder in SPH4 average 0.000114 pastas, by in case do not use 0.000757, I appeared more greatly when used tray when did not use both SPH4 and SPH5 tray holder, but 1 appeared is not level to keep in mind(Table 8~9). 3 SPH4 was looked very big mindfulness in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon without using tray holder(P< 0.001). I use tray holder and SPH4 did not appear synonymy in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon(P>0.05). Study finding of above when see synthesis Alginate certainly tray holder use must and I could know that hardening method does not exert big influence on volume stability if remove impression sieve of excess because amity sex accessory penalty silicon passes over tray, Also, Alginate impression material previewed can get heading a conspiracy style that volume stability of accessory penalty silicon impression material degree is if use tray holder.

  • PDF

한국 성인 유치악자의 상악전치 위치에 관한 연구 (A Study on the Position of the Maxillary Anterior Teeth in Korean Adults with Natural Dentition)

  • 정창모;박정형
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.105-111
    • /
    • 2005
  • It is essential to establish the suitable position for artificial maxillary anterior teeth, because of not only esthetics, phonetics, mastication, but also optimal position of artificial posterior teeth for the construction of functional and esthetic prostheses. Anatomic landmarks have been used in the arrangement of artificial teeth. Such as incisive papilla and palatal rugae are useful landmarks for positioning occlusal rim and upper anterior artificial teeth because they are relatively stable and to be identified on master cast. Therefore, if average distance between maxillary anterior teeth and landmarks in dentate subjects are measured and applied, appropriate position of occlusal rim can be initially established. In this study, to present a guide to the position of the occlusal rim for upper anterior teeth of edentulous patients, horizontal distance between anatomic landmarks were measured. Maxillary casts were made in 72 Korean dentate subjects. Horizontal distance between central incisor and incisive papilla, between incisive papilla and intercanine line, and between primary palatine rugae and gingival margin of canine were measured on each cast. The results of this study were as follows ; 1. The mean distance from the incisal edge of central incisor to the posterior border of incisive papilla was 12.1 mm (Male 12.2 mm, Female 11.9 mm). 2. The mean distance between posterior border of incisive papilla and intercanine line was 3.5 mm (Male 3.4 mm, Female 3.6 mm / Left 3.6 mm, Right 3.4 mm). 3. The mean distance from the palatal gingival margin of canine to the lateral border of primary palatine rugae was 2.4 mm (Male 2.4 mm, Female 2.4 mm / Left 2.4 mm, Right 2.3 mm). 4. On all measured items, there were no significant differencies in measured values between male and female, and between left and right sides. (P>0.05).

THE EFFECTS OF SPURE AND INVENTS ON THE CASTING ACCURACY AND POROSITY OF TI-NI CASTINGS

  • Cho Lee-Ra;Yi Yang-Jin;Park Chan-Jin
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.342-350
    • /
    • 2003
  • Statement of problem. Titanium-Nickel alloy might be used in various prosthetic restorations since it has a unique property such as super-elasticity and high fatigue resistance. However, little is known about the casting ability of this alloy. Purpose. This in vitro study compared the casting accuracy and the porosity made with different investments and various sprue designs to ascertain what casting condition would be better for the fabrication of Ti-Ni cast restorations. Material and methods. A total of 70 Ti-Ni alloy crowns were made and divided into 7 groups of 10 copings on a metal master die. For measuring the effect of the sprue numbers, two groups with one and two 8-gauge sprues were compared. Moreover, the results of the conventional sprue and the double thickness sprues were compared. Three investments were used; carbon free phosphate bonded investment, titanium investment and gypsum bonded investment. The cast restorations were evaluated at 48 points on the entire circumferential margin with a stereomicroscope measuring in micrometers. Each crown was radiographically examined for casting defects and porosity. Data on casting accuracy were analyzed using two-way and Post hoc Scheffe's comparison to determine whether significant differences existed at the 95% confidence level. Student-Newman-Keuls test were performed to identify significant differences in the number of voids. Results. The double sprueing group and double thickness group had significantly less marginal discrepancy than the single sprueing group (P<.05 and P<.01, respectively). The castings with phosphate bonded investment showed the least marginal discrepancy and the smoothest surface. The castings invested in the gypsum bonded investment had the greatest gaps in margin and the largest failure rate. The double sprueing group and phosphate bonded investment group had significantly smaller void numbers and smaller void size than the other groups. Conclusion. Within the limitations of this in vitro study, the casting accuracy of the groups using thicker, double sprue design and the phosphate bonded investment was significantly superior. Moreover, void number and size were less than other groups.

Development of implant loading device for animal study about various loading protocol: a pilot study

  • Yoon, Joon-Ho;Park, Young-Bum;Cho, Yuna;Kim, Chang-Sung;Choi, Seong-Ho;Moon, Hong-Seok;Lee, Keun-Woo;Shim, June-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.227-234
    • /
    • 2012
  • PURPOSE. The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS. Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method, simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (${\mu}{\varepsilon}$) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS. The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION. Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study.

입자미세화가 Al-4.8%Cu-0.6%Mn 합금의 유동도에 미치는 영향 (The Effect of Grain Refinement on Fluidity of Al-4.8%CU-0.6%Mn Alloy)

  • 권영동;이진형;김경현
    • 한국주조공학회지
    • /
    • 제22권3호
    • /
    • pp.109-113
    • /
    • 2002
  • A good fluidity of high strength Al-alloys is required to cast thin wall castings needed to reduce the weight of cast parts. The fluidity, measured as the length to which the metal flows in a standard channel, is affected by many factors, such as the pouring temperature, solidification type of the alloy, the channel thickness, melt head, mold materials and temperature, coating etc. Therefore the experimentally measured fluidity scatters very much and makes it difficult to estimate the fluidity of a melt with a few measurements. The effect of Ti content and grain refinement on the fluidity of high strength aluminum alloy was investigated with a test casting with 8 thin flow channels to reduce the scattering of the fluidity results. The fluidity of Al-4.8%Cu-0.6%Mn Al-6.2%Zn-1.6%Mg-1.0%Cu and well-known commercial aluminum alloy, A356 was tested. Initial content of Ti was varied from 0 to 0.2wt% and Al-5Ti-B master alloy was added for grain refinement. The flow length varied linearly with superheat. By adding Ti and Al-5Ti-B, the fluidity increased. The grain size decreased by adding grain refiner at the same time. The fluidity depended on the degree of grain refinement. The fluidity of the alloy solidifying in mushy type is improved by grain refinement, because grain refinement increases the solid fraction at the time of flow stoppage.

Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

  • Lee, Suji;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.55-64
    • /
    • 2019
  • PURPOSE. The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS. The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at ${\alpha}=.05$. RESULTS. No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION. The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.

의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구 (DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING)

  • 최훈달;권긍록;김형섭;최대균
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.