• Title/Summary/Keyword: mass products

Search Result 1,554, Processing Time 0.034 seconds

SAMI Galaxy Survey Data Release 2: Absorption-line Physics

  • Oh, Sree;Scott, Nicholas;van de Sande, Jesse
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.53.1-53.1
    • /
    • 2018
  • We present the second data release from the SAMI Galaxy Survey. The data release contains reduced spectral cubes for 1559 galaxies, about 50% of the full survey, having a redshift range 0.004 < z < 0.113 and a large stellar mass range 7.5 < log($M_*/M_{\odot}$) < 11.6. This release also includes stellar kinematic and stellar population value-added products derived from absorption line measurements, and all emission line value-added products from Data Release One. The data are provided online through Australian Astronomical Optics' Data Central. Our poster presents stellar/gas kinematics on the metallicity-mass plane and highlight several galaxies from the SAMI Galaxy Survey that have interesting stellar and gas kinematics. For more information about data release 2, please see: https://sami-survey.org/abdr.

  • PDF

A study on analytical methods for polycyclic aromatic hydrocarbons in foods (식품 중 다환방향족탄화수소 분석법 연구)

  • Kim, Yong-Yeon;Shin, Han-Seung
    • Food Science and Industry
    • /
    • v.55 no.1
    • /
    • pp.45-57
    • /
    • 2022
  • This study was proceeded the analytical methods using various analytical instruments for polycyclic aromatic hydrocarbons (PAHs) in food products. Various analytical methods were developed to determine levels of PAHs including benzo[a]pyrene, benzo[a]anthracene, benzo[b]fluoranthene, and chrysene formed in various food products using gas chromatography-mass spectrometry (GC-MS), enzyme-linked immunosorbent assay (ELISA) and raman spectroscopy. Recently, the rapid on-site response for the detection of hazardous substances in food aims to develop an onsite rapid detection of a simplified technical analysis method to reduce the time and cost required for analysis of PAHs. Current PAHs detection methods have been reviewed along with new raman spectroscopy analytical method.

Analytical Method for Determination of Microstructure of SBR and SBR Content in Blended Rubber Composites Using Pyrolytic Technique

  • Eunji Chae;Sung-Seen Choi
    • Elastomers and Composites
    • /
    • v.57 no.4
    • /
    • pp.188-196
    • /
    • 2022
  • Styrene-butadiene rubber(SBR) is a copolymer of styrene and butadiene. It is composed of 1,2-unit, 1,4-unit, and styrene, and its properties are dependent on its microstructure. In general, rubber composites contain a single rubber or a blended rubber. Similarly, SBR is used by mixing with natural rubber(NR) and butadiene rubber(BR). The composition of a rubber article affects its physical and chemical properties. Herein, an analytical method for determining the microstructure of SBR using via pyrolysis is introduced. Pyrolysis-gas chromatography/mass spectrometry is widely used to analyze the microstructure of polymeric materials. The microstructure of SBR can be determined by analyzing the principal pyrolysis products formed from SBR, such as 4-vinylcyclohexene, styrene, 2-phenylpropene, 3-phenylcyclopentene, and 4-phenylcyclohexene. An analytical method for determining the composition of SBR/NR, SBR/BR, and SBR/NR/BR blends via pyrolysis is introduced. The composition of blended rubber can be determined by analyzing the principal pyrolysis products formed from each rubber component.

A study on the quantitative risk grade assessment of initial mass production for weapon systems (초도양산 군수품에 대한 정량적 위험등급평가 방안 연구)

  • Jung, Yeongtak;Ham, Younghoon;Roh, Taegoo;Ahn, Manki;Ko, Kyungwa
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.441-452
    • /
    • 2018
  • Purpose: The purpose of this paper is to study quantitative risk grade assessment for objective government quality assurance activities based on risk management in initial mass production for weapon systems. Methods: The Defense quality management regulations and foreign risk assessment documents are referred to analyze problems performing quality assurance actives. The failure rate data, maintainability and cost of products have been studied to quantify the risk Likelihood and impact. The analyzed data were classified as risk grade assessment through K-means Cluster Analysis method. Results: Results show that a proposed method can objectively evaluate risk grade. The analyzed results are clustered into three levels such as high, middle and low. Two products are allocated high, eleven low and seven middle. Conclusion: In this paper, quantitative risk grade assessment methods were presented by analyzing risk ratings based on objective data. The findings showed that the methods would be effective for initial mass production for weapon systems.

Photodegradation of Phosphamidon and Profenofos (Phosphamidon과 Profenofos의 광분해성)

  • 민경진;차춘근
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.49-58
    • /
    • 2000
  • The present study was performed to investigate photodegradation rate constants and degradation products of phosphamidon and profenofos by the USEPA method. The two pesticides were very stable in 16 days exposure of sunlight from September 3 to 22, 1999 and humic acid had no sensitizing effect on the photolysis of each pesticide in sunlight. In the UV irradiation test, phosphamidon was rapidly degraded as increasing UV intensity. In case of UV irradiation with TiO2 and with TiO2 powder amount, degradation of profenofos showed no significant difference with UV irradiation. Photodegradation rate of profenofos was slower than that of phosphamidon. In order to identify photolysis products, the extracts of degradation products were analyzed by GC/MS. The mass spectra of photolysis products of phosphamidon were at m/z 153 and 149, those of the profenofos were at m/z 208 and 240, respectively. It was suggested that the photolysis products of phosphamidon were 0, 0-dimethyl phosphate(DMP) and N, N-diethylchloroacetamide, those of profenofos were 4-bromo-2-chlorophenol and 0-ethyl-S-propyl phosphate.

  • PDF

Oxidation Products from the Mixture of $\alpha$-Tocopherol and ${\gamma}$-Tocopherol during Autoxidation of Methly Linoleate (Methyl Linoleate의 자동산화에 따른 $\alpha$-Tocopherol과 ${\gamma}$-Tocopherol 혼합계의 산화생성물)

  • 하귀현
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.19 no.3
    • /
    • pp.239-247
    • /
    • 1990
  • The oxidation products from the mixture of a-tocopherol (a-Toc) and γ-tocopherol)(γ-Toc) during autoxidation of methyl linoleate were isolated and identified. The sturctures of the oxida-tion products were characterized by UV, IR, 1H and 13CNMR and mass spectrometry 5-[2-(a-tocopherol-5'-yl)ethyl]-a-tocopherylquinone 5-[2-(a-tocopherol-5'-yl)ethyl]-8a-hydroxy-a-tocopherone and O-[8-(5-ethoxymethyl-7-methyltocol) methyl] a-tocopherol were obained from the mixture as the oxidation products derived from γ-Toc However oxidation product composed of both a-ToC and γ-Toc was detected in oxidation products of the misture. These results support the facts that at first oxidation of a-Toc proceeds during autoxidation of lipids and then γ-Toc decomposes after approximate consumption of a-Toc.

  • PDF

Pyrolysis Properties of Lignins Extracted from Different Biorefinery Processes

  • Lee, Hyung Won;Jeong, Hanseob;Ju, Young-Min;Youe, Won-Jae;Lee, Jaejung;Lee, Soo Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.486-497
    • /
    • 2019
  • The non-isothermal and isothermal pyrolysis properties of H lignin and P lignin extracted from different biorefinery processes (such as supercritical water hydrolysis and fast pyrolysis) were studied using thermogravimetry analysis (TGA) and pyrolyzer-gas chromatography/mass spectrometry (Py-GC/MS). The lignins were characterized by ultimate/proximate analysis, FT-IR and GPC. Based on the thermogravimetry (TG) and derivative thermogravimetry (DTG) curves, the thermal decomposition stages were obtained and the pyrolysis products were analyzed at each thermal decomposition stage of non-isothermal pyrolysis. The isothermal pyrolysis of lignins was also carried out at 400, 500, and $600^{\circ}C$ to investigate the pyrolysis product distribution at each temperature. In non-isothermal pyrolysis, P lignin recovered from a fast pyrolysis process started to decompose and produced pyrolysis products at a lower temperature than H lignin recovered from a supercritical water hydrolysis process. In isothermal pyrolysis, guaiacyl and syringyl type were the major pyrolysis products at every temperature, while the amounts of p-hydroxyphenyl type and aromatic hydrocarbons increased with the pyrolysis temperature.

Simultaneous Quantification of 13 Ginsenosides by LC-MS/MS and its Application in Diverse Ginseng Extracts

  • Jo, Jung Jae;Cho, Pil Joung;Lee, Sangkyu
    • Mass Spectrometry Letters
    • /
    • v.9 no.2
    • /
    • pp.41-45
    • /
    • 2018
  • Ginseng (Panax ginseng Meyer) has been used as traditional herbal drug in Asian countries. Ginsenosides are major components having pharmacological and biological efficacy like anti-inflammatory, anti-diabetic and anti-tumor effects. To control the quality of the components in diverse ginseng products, we developed a new quantitative method using LC-MS/MS for 13 ginsenosides; Rb1, Rb2, Rc, Rd, Re, Rf, 20(S)-Rh1, 20(S)-Rh2, Rg1, 20(S)-Rg3, F1, F2, and compound K. This method was successfully validated for linearity, precision, and accuracy. This quantification method applied in four representative ginseng products; fresh ginseng powder, white ginseng powder, red ginseng extract powder, and red ginseng extract. Here the amounts of the 13 ginsenosides in the various type of ginseng samples could be analyzed simultaneously and expected to be suitable for quality control of ginseng products.

Determination of Emamectin Benzoate in Eel, Halibut, and Shrimp Using QuEChERS-EDTA and LC-MRM

  • Cho, Ha Ra;Kim, Dong Yoon;Lee, Hyo Chun;Han, Sang Beom;Shin, Ho-Chul;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.9 no.4
    • /
    • pp.100-104
    • /
    • 2018
  • As a part of efforts to establish the positive list system (PLS) in South Korea, a method to determine residual emamectin benzoate (EB) in various aquatic products using QuEChERS-EDTA and LC-MRM was developed. The developed method was validated in the aspects of specificity, linearity (correlation coefficient of at least 0.996), sensitivity (the limit of detection and the lower limit of quantitation ${\leq}5ng/g$), recovery (the recovery range of 87.4 and 96.2), and precision (the relative standard deviation of recovery between 0.9 and 13.5). Additionally, the validated method was successfully applied for monitoring EB contamination in eel, halibut, and shrimp collected from local food markets. To our knowledge, the present method is the first one to determine residual EB in various aquatic products at the level satisfying the PLS and could contribute to the establishment of the PLS in South Korea.

Trifluralin in aquatic products: QuEChERS and Gas chromatography-tandem mass spectrometry for trace amount detection

  • Le-Thi Anh-Dao;Do Minh-Huy;Vo Hong-Phong;Nguyen Cong-Hau
    • Analytical Science and Technology
    • /
    • v.36 no.5
    • /
    • pp.205-215
    • /
    • 2023
  • In the present study, an analytical method was proposed for detecting trifluralin in aquatic products at trace concentrations. The method employed QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) and gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) as the sample preparation and measurement, respectively. The effect of the aqueous phase volume used in the QuEChERS was demonstrated, and the ratio of 10:10 (mL) between water and acetonitrile phase was used for 5 g of sample. Besides, dSPE using C18 and primary-secondary amine (PSA) was applied to remove the potential interferences from the food matrices, indicating no remarkable analyte loss. The linear range was built up from 0.50 ㎍ L-1 to 3.0 ㎍ L-1 (R2 = 0.9993). Other criteria, i.e., repeatability (RSDr = 0.86-1.96 %), reproducibility (RSDR = 1.09-2.01 %), and recovery (over 90 %), were in accordance with Appendix F of AOAC (2016) for method performance. Although no trifluralin was detected for the commercial samples (fish, shrimp, and breaded shrimp), the spiked samples performed favorable recoveries and precision.