• 제목/요약/키워드: mass interference

Search Result 142, Processing Time 0.03 seconds

A Report on 6 cases of Abdominal Obesity using Electroacupuncture Combined with Magnetic Acupuncture (전기와 자기장 복합 침 자극을 활용한 복부비만 치료 6례에 대한 증례 보고)

  • Yun, Gee Won;Lee, Hyun;Kim, Yun Joo;Kang, Jae Hui
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.213-226
    • /
    • 2015
  • Objectives : This study was aimed to show the effect of electroacupuncture combined with magnetic acupuncture on abdominal obesity without patient dieting, exercise or use of herbal medication. Methods : Women over 85 cm in waist circumference were treated with electroacupuncture combined with magnetic acupuncture. Acupuncture points were located at the abdomen ($CV_{12}$, $CV_6$, $ST_{25}$, $ST_{21}$, $SP_{15}$, $SP_{14}$), extremities ($LI_4$, $LI_{11}$, $ST_{36}$, $ST_{44}$) and were stimulated 30 minutes with 2.1~3 Gaus, 500 Hz, tolerable strength. The Interference wave forms were by Whata 153 (Medi Lab, Korea). Two or three treatment sessions per week (five or ten sessions in total) were done. Before treatment, and after the last treatment, we measured waist circumference, hip circumference, waist hip ratio, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio, visceral fat area, free fat mass, body fat mass and skeletal muscle mass. We also measured the subcutaneous temperature of the abdomen($CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$, $CV_6$) by using digital infrared thermal imaging(DITI). Results : In this study, significant reductions were shown in waist circumference, hip circumference, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio and body fat mass. There were no significant differences in waist hip ratio, free fat mass or skeletal muscle mass. There were also significant increases of the subcutaneous temperature on $CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$. Conclusions : From the above results, electroacupuncture combined with magnetic acupuncture might be an effective treatment for abdominal obesity.

Optimal Conditions for Pretreated Sample for Sr Isotope Analysis by MC-ICP-MS: A Comparison Between Eichrom (SR-R50-S)'s and Bio-Rad(AG®50W-X8)'s Resins (다검출기 유도결합 플라즈마 질량분석기에 의한 Sr 동위원소 분석을 위해 전처리된 시료의 최적 조건: Eichrom사 Sr 수지(SR-R50-S)와 Bio-Rad사 수지(AG®50W-X8) 비교)

  • Myoung Jung, Kim;Seung-Gu, Lee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.507-520
    • /
    • 2022
  • The Sr isotope ratio, which is used as basic data for rock formation time, crustal and mantle evolution studies, is determined by mass spectrometer such as thermal ionization mass spectrometry (TIMS) or multi-detector inductively coupled plasma mass spectrometry (MC-ICP-MS). In this technical report, we compared how incomplete chemical separation of elements affects the determination of Sr isotope ratios. For the experiment, commercial resin, NBS987(NIST SRM987) Sr isotope standard, and rock standard samples from the Geological Survey of Japan (GSJ) such as JG1a, JB3 and JA1 were used. As a result of the comparative experiment, it was clearly observed that the measured values of 87Sr/86Sr change when Rb remains due to incomplete separation of the NBS987 Sr isotope standard sample as well as the rock standard samples of GSJ. This indicates that complete separation is an important factor since the calculated value deviates from the true value even though correction for isotope interference by isobar is performed when measuring the isotope ratio with MC-ICP-MS. This also suggests that, when reporting the measurement result of Sr isotope ratio using MC-ICP-MS, the measurement strength of 85Rb should be reported together with the measurement strength of all isotopes of Sr so that isotope interference by isobar can be judged.

A Study on the Machine Interference Time (기계간섭시간에 관한 연구)

  • 강경식;고용해;유지철
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.6 no.8
    • /
    • pp.55-61
    • /
    • 1983
  • In order to increase productivity, modern business which use the techniques of mass production should progress gradually from to use of human labor to total mechanization in the various steps of the production process. This will not only avoid the prospect of future labor shortages, but will also solve nancy of the problems involved in increasing productivity In this paper, we have approached the problem of determining the number of machine units that can be economically assigned to one operator by using Palm's model.

  • PDF

Haematococcus pluvialis Cell-Mass Sensing Using Ultraviolet Fluorescence Spectroscopy

  • Lababpour, Abdolmajid;Hong, Seong-Joo;Lee, Choul-Gyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.12
    • /
    • pp.1922-1929
    • /
    • 2007
  • A simple whole-cell-based sensing system is proposed for determining the cell mass of H. pluvialis using ultraviolet fluorescence spectroscopy. An emission signal at 368 nm was used to detect the various kinds of green, green-brown, brown-red, and red H. pluvialis cells. The fluorescence emission intensities of the cells were highest at 368 nm with an excitation wavelength of 227 nm. An excitation wavelength of 227 nm was then selected for cell-mass sensing, as the emission fluorescence intensities of the cell suspensions were highest at this wavelength after subtracting the background interference. The emission fluorescence intensities of HPLC-grade water, filtered water, and HPLC-grade water containing a modified Bold's basal medium (MBBM) were measured and the difference was less than 1.6 for the selected wavelengths. Moreover, there was no difference in the emission intensity at 368 nm among suspensions of the various morphological states of the cells. A calibration curve of the fluorescence emission intensities. and cell mass was obtained with a high correlation ($R^2=0.9938$) for the various morphological forms of H. pluvialis. Accordingly, the proposed method showed no significant dependency on the various morphological cell forms, making it applicable for cell-mass measurement. A high correlation was found between the fluorescence emission intensities and the dry cell weight with a mixture of green, green-brown, brown-red, and red cells. In conclusion, the proposed model can be directly used for cell-mass sensing without any pretreatment and has potential use as a noninvasive method for the online determination of algal biomass.

Isotope Measurement of Uranium at Ultratrace Levels Using Multicollector Inductively Coupled Plasma Mass Spectrometry

  • Oh, Seong-Y.;Lee, Seon-A.;Park, Jong-Ho;Lee, Myung-Ho;Song, Kyu-Seok
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.54-57
    • /
    • 2012
  • Mass spectrometric analysis was carried out using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for the precise and accurate determination of the isotope ratios of ultratrace levels of uranium dissolved in 3% $HNO_3$. We used the certified reference material (CRM) 112-A at a trace level of 100 pg/mL for the uranium isotopic measurement. Multiple collectors were utilized for the simultaneous measurement of uranium isotopes to reduce the signal uncertainty due to variations in the ion beam intensity over time. Mass bias correction was applied to the measured U isotopes to improve the precision and accuracy. Furthermore, elemental standard solution with certified values of platinum, iridium, gold, and thallium dissolved in 3% $HNO_3$ were analyzed to investigate the formation rates of the polyatomic ions of $Ir^{40}$ $Ar^+$, $Pt^{40}$ $Ar^+$, $Tl^{40}$ $Ar^+$, $Au^{40}$ $Ar^+$ for the concentration range of 50-400 pg/mL. Those polyatomic ions have mass-to-charge ratios in the 230-245 m/z region that it would contribute to the increase of background intensity of uranium, thorium, plutonium, and americium isotopes. The effect of the polyatomic ion interference on uranium isotope measurement has been estimated.

Analysis of Ultra Pure Sulfuric Acid for Semiconductor Using High Resolution ICP-MS (고분해능 ICP-MS를 이용한 반도체용 고순도 황산 분석)

  • Heo, Y.W.;GiI, J.I.;Lim, H.B.
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.311-315
    • /
    • 1998
  • Ultra trace metal impurities of high-purity sulfuric acid for semiconductor process have been determined in the concentration of lower than ppb (ng/g) level using high resolution inductively coupled plasma mass spectrometer (HR-ICP-MS).The acid samples were evaporated and concentrated by the factor of 20. No clement in the acids exceeded 1ppb level and most of the clements were determined below 10ppt (pg/g). Elements without spectral interference in mass spectrum, such as In, V, Mn, etc, were determined in the concentration of below 1 ppt level The recoveries in the range of 72% to 127.2% for 0.5 ppb spiked sample were obtained.

  • PDF

Smart modified repetitive-control design for nonlinear structure with tuned mass damper

  • ZY Chen;Ruei-Yuan Wang;Yahui Meng;Timothy Chen
    • Steel and Composite Structures
    • /
    • v.46 no.1
    • /
    • pp.107-114
    • /
    • 2023
  • A new intelligent adaptive control scheme was proposed that combines observer disturbance-based adaptive control and fuzzy adaptive control for a composite structure with a mass-adjustable damper. The most important advantage is that the control structures do not need to know the uncertainty limits and the interference effect is eliminated. Three adjustable parameters in LMI are used to control the gain of the 2D fuzzy control. Binary performance indices with weighted matrices are constructed to separately evaluate validation and training performance using the revalidation learning function. Determining the appropriate weight matrix balances control and learning efficiency and prevents large gains in control. It is proved that the stability of the control system can be ensured by a linear matrix theory of equality based on Lyapunov's theory. Simulation results show that the multilevel simulation approach combines accuracy with high computational efficiency. The M-TMD system, by slightly reducing critical joint load amplitudes, can significantly improve the overall response of an uncontrolled structure.

Analysis of Glycerol with Isolation of Endogenous Interferences using "Dilute and Shoot" Strategy and High-Resolution Mass Spectrometry in Human Urine for Antidoping Testing

  • Kim, Yongseok;Min, Hophil;Sung, Changmin;Park, Ju-hyung;Son, Junghyun;Lee, Kang Mi;Kim, Ho Jun;Lee, Jaeick;Kwon, Oh-Seung;Kim, Ki Hun
    • Mass Spectrometry Letters
    • /
    • v.7 no.4
    • /
    • pp.111-115
    • /
    • 2016
  • Glycerol was identified and isolated from endogenous interferences during analysis of human urine using high-resolution mass spectrometry (HRMS) for doping control. Urinary sample preparation was simple; the samples were diluted with an organic solvent and then analyzed using a liquid chromatography-mass spectrometry ("dilute and shoot" method). Although the interfering ion peaks were observed at the similar retention time of glycerol, the inference could be identified by isolation with HRMS and further investigation. Thus, creatinine was identified as the endogenous interference for glycerol analysis and it also caused ion suppression resulting in the decrease of glycerol signal. This study reports the first identification and efficient isolation of endogenous interferences in human urine for "dilute and shoot" method. The information about ion suppression could be novel to prevent overestimation or a false result for antidoping analysis.

The simultaneous determination of germanium and selenium in plant by hydride vapour generator inductively coupled plasma mass spectrometry (HVG-ICPMS을 이용한 식물체 중 게르마늄과 셀레늄의 동시분석 연구)

  • Ham, Yong-Gyu;Kim, Bo-Kyong;Kwon, Young-Uk;Baek, Hyo-Hyu;Lee, Seok-Ki
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.159-167
    • /
    • 2011
  • In this study, the hydride vapour generator inductively coupled plasma mass spectrometry (HVGICPMS) was applied as the new analytical method to show the high accurate and reproductive data analysing the amounts of selenium and germanium being existed inside a system of plant. In order to decrease the interference effects, such as ion and molecular interference. Mini torch was used into the ICPMS instead of the conventional torch. At conditions of the different kinds and concentrations of acid solution, the different reductive conditions for composing hydride, and the different methods for making ash, the contents of selenium and germanium in lettuce were analysed. The inspection of yields and data comparison from SRM-1574 and -1570a were used for increasing the accuracy of this analysis.

A Case Report of Symptomatic Torus Palatinus (구개 융기의 치험례)

  • Kwon, Jun-Seong;Choi, Hwan-Jun;Yang, Hyung-Eun;Tark, Min-Seong
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.473-476
    • /
    • 2010
  • Purpose: Torus palatinus is a bony prominence at the middle of the hard palate. The size varies from barely discernible to very large, from flat to lobular. This oral exostosis is not a disease or a sign of disease, but if large, may be a problem. So, we present the clinical and histopathologic features and applied therapy and provide a comprehensive review of the rare case of the symptomatic exostoses. Methods: A 37-year-old woman had slowly growing exophytic nodular mass of the bone that arises the midline suture of the hard palate. The patient was concerned about discomfort associated with movement of her tongue and about frequent irritation of the palatal mucosa during mastification of the hard food. The patient had a large, unilobulated torus palatinus. It extended from the area adjacent to the canine to a point beyond the junction with the soft palate. The mass was oblong in shape, measuring about 3 cm long, 2 cm wide, and 0.8 cm in height. Results: Before surgical intervention a CT was obtained for the sake of estimating the thickness of the bone between the exostoses and the maxillary antrum and floor of the nose. The surgical procedure was performed with the patient under general anesthesia. Removal of the exostosis was performed after midline mucoperiosteal incision with osteotome and diamond burr. Histologic finding revealed decalcified dense bony tissue, the presence of lacunae, and normal osteocytes. Conclusion: Surgical removal is recommended when one or more of the following condition exist: interference with the construction of prosthesis, interference with oral function, irritation or pathology of the overlying tissue, inability of the patient to maintain proper oral hygiene, and fear of malignancy or other psychologic trauma. We report a rare case of the torus arising in hard palate with symptoms.