Browse > Article
http://dx.doi.org/10.5478/MSL.2016.7.4.000

Analysis of Glycerol with Isolation of Endogenous Interferences using "Dilute and Shoot" Strategy and High-Resolution Mass Spectrometry in Human Urine for Antidoping Testing  

Kim, Yongseok (Doping Control Center, Korea Institute of Science and Technology)
Min, Hophil (Doping Control Center, Korea Institute of Science and Technology)
Sung, Changmin (Doping Control Center, Korea Institute of Science and Technology)
Park, Ju-hyung (Doping Control Center, Korea Institute of Science and Technology)
Son, Junghyun (Doping Control Center, Korea Institute of Science and Technology)
Lee, Kang Mi (Doping Control Center, Korea Institute of Science and Technology)
Kim, Ho Jun (Doping Control Center, Korea Institute of Science and Technology)
Lee, Jaeick (Doping Control Center, Korea Institute of Science and Technology)
Kwon, Oh-Seung (Doping Control Center, Korea Institute of Science and Technology)
Kim, Ki Hun (Doping Control Center, Korea Institute of Science and Technology)
Publication Information
Mass Spectrometry Letters / v.7, no.4, 2016 , pp. 111-115 More about this Journal
Abstract
Glycerol was identified and isolated from endogenous interferences during analysis of human urine using high-resolution mass spectrometry (HRMS) for doping control. Urinary sample preparation was simple; the samples were diluted with an organic solvent and then analyzed using a liquid chromatography-mass spectrometry ("dilute and shoot" method). Although the interfering ion peaks were observed at the similar retention time of glycerol, the inference could be identified by isolation with HRMS and further investigation. Thus, creatinine was identified as the endogenous interference for glycerol analysis and it also caused ion suppression resulting in the decrease of glycerol signal. This study reports the first identification and efficient isolation of endogenous interferences in human urine for "dilute and shoot" method. The information about ion suppression could be novel to prevent overestimation or a false result for antidoping analysis.
Keywords
Mass spectrometry; Doping control; Dilute and shoot; Orbitrap; Glycerol analysis;
Citations & Related Records
연도 인용수 순위
  • Reference
1 WADA. The 2016 prohibited list international standard, https://www.wada-ama.org/en/international-standards. 2016.
2 Polyviou, T. P.; Easton, C.; Beis, L.; Malkova, D.; Takas, P.; Hambly, C.; Speakman, J. R.; Koehler, K.; Pitsiladis, Y. P. Nutr. 2012, 4, 1171.
3 Nash, T. Biochem. J. 1953, 55, 416.   DOI
4 Thevis, M.; Guddat, S.; Flenker, U.; Schanzer, W. Eur. J. Mass Spectrom. 2008, 14, 117.   DOI
5 Dong, Y.; Yan, K.; Ma, Y.; Yang, Z.; Zhao, J.; Ding, J. J. Chromatogr. B 2016, 1022, 153.   DOI
6 Dong, Y.; Ma, Y.; Yan, K.; Shen, L.; Wang, X.; Xu, Y.; He, G.; Wu, Y.; Lu, J.; Yang, Z.; Feng, F. J. Chromatogr. B 2014, 957, 30.   DOI
7 Jeong, E. S.; Kim, S. H.; Cha, E. J.; Lee, K. M.; Kim, H. J.; Lee, S. W.; Kwon, O. S.; Lee, J. Rapid Commun. Mass Spectrom. 2015, 29, 367.   DOI
8 Gorgens, C.; Guddat, S.; Orlovius, A. K.; Sigmund, G.; Thomas, A.; Thevis, M.; Schanzer, W. Anal. Bioanal. Chem. 2015, 407, 5365.   DOI
9 Jimenez Giron, A.; Deventer, K.; Roels, K.; Van Eenoo, P. Anal. Chim. Acta 2012, 721, 137.   DOI
10 Guddat, S.; Solymos, E.; Orlovius, A.; Thomas, A.; Sigmund, G.; Geyer, H.; Thevis, M.; Schanzer, W. Drug Test. Anal. 2011, 3, 836.   DOI
11 Fitzgerald, R. L.; Griffin, T. L.; Yun, Y. M.; Godfrey, R. A.; West, R.; Pesce, A. J.; Herold, D. A. J. Anal. Toxicol. 2012, 36, 106.   DOI
12 Beck, O.; Ericsson, M. Bioanalysis 2014, 6, 2229.   DOI
13 Annesley, T. M. Clin. Chem. 2003, 49, 1041.   DOI
14 Schlittenbauer, L.; Seiwert, B.; Reemtsma, T. Rapid Commun. Mass Spectrom. 2016, 1560.