• Title/Summary/Keyword: mass drug administration

Search Result 196, Processing Time 0.043 seconds

Screening of Nitrosamine Impurities in Sartan Pharmaceuticals by GC-MS/MS

  • Chang, Shu-Han;Ho, Hui-Yu;Zang, Chi-Zong;Hsu, Ya-Hui;Lin, Mei-Chih;Tseng, Su-Hsiang;Wang, Der-Yuan
    • Mass Spectrometry Letters
    • /
    • v.12 no.2
    • /
    • pp.31-40
    • /
    • 2021
  • Probable human carcinogenic compounds nitrosamines, have been detected as by-product impurities in sartan pharmaceuticals in recent years which has drawn worries for medication safety. To provide a sensitive and effective method for the quality control of sartan pharmaceuticals, this study established a feasible gas chromatography-tandem mass spectrometry (GC-MS/MS) method for simultaneous determination of 13 nitrosamines. The target analytes were separated on a DB-WAX Ultra Inert column (30 m × 0.25 mm; i.d., 0.25 ㎛) and were then subjected to electron impact ionization in multiple reaction monitoring mode. The established method was validated and further employed to analyze authentic samples. Limits of detection (LODs) and limits of quantification (LOQs) of the 13 nitrosamines were 15-250 ng/g and 50-250 ng/g, respectively, which also exhibited intra-day and inter-day accuracies of 91.4-104.8%, thereby satisfying validation criteria. Five nitrosamines, viz., N-nitrosodiethylamine, N-nitrosodimethylamine, N-nitrosodiphenylamine, N-nitrosomorpholine, and N-nitrosopiperidine were detected at concentrations above their LODs in 68 positive samples out of 594 authentic samples from seven sartans.

Development of a Quantitative Analytical Method for Determining the Concentration of Human Urinary Paraben by LC-MS/MS

  • Lee, Seung-Youl;Son, Eunjung;Kang, Jin-Young;Lee, Hee-Seok;Shin, Min-Ki;Nam, Hye-Seon;Kim, Sang-Yub;Jang, Young-Mi;Rhee, Gyu-Seek
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1131-1136
    • /
    • 2013
  • Parabens, the esters of p-hydroxybenzoic acid, have been widely used as antimicrobial preservatives in cosmetic products, drugs, and processed foods and beverages. However, some parabens have been shown to have weak estrogenic effects through in vivo and in vitro studies. Because such widespread use has raised concerns about the potential human health risks associated with exposure to parabens, we developed a simultaneous analytical method to quantify 4 parabens (methyl, ethyl, propyl, and butyl) in human urine, by using solid-phase extraction and high-performance liquid chromatography coupled with triple quadrupole mass spectrometry. This method showed good specificity, linearity ($R^2$ > 0.999), accuracy (92.2-112.4%), precision (0.9-9.6%, CV), and recovery (95.7-102.0%). The LOQs for the 4 parabens were 1.0, 0.5, 0.2, and 0.5 ng/mL, respectively. This method could be used for quick and accurate analysis of a large number of human samples in epidemiological studies to assess the prevalence of human exposure to parabens.

Determination of finasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 finasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.345-351
    • /
    • 2011
  • A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method was developed and validated for the determination of finasteride in human serum. Beclomethasone was used as internal standard (IS) and liquid-liquid extraction (LLE) using methyl tert-butyl ether (MTBE) was carried out to isolate analyte. The mass transitions monitored in multiple reaction monitoring (MRM) in positive ion mode were m/z 373.2${\rightarrow}$305.2 for finasteride and m/z 409.3${\rightarrow}$391.2 for IS. Retention times of finasteride and IS were 5.81 and 5.46 min, respectively. The limit of quantitation (LOQ) was 0.1 ng/mL and the calibration curve showed good linearity in the range of 0.1~20.0 ng/mL ($R^2$=0.9997). The intra-day assay precision and accuracy were in the range 6.3~10.6% and 97.3~103.6%, respectively, and the inter-day assay precision and accuracy were in the range 0.8~5.2% and 99.8~102.5%, respectively. The sample extract recovery of the method was 80~83%.

Method Development for the Profiling Analysis of Endogenous Metabolites by Accurate-Mass Quadrupole Time-of-Flight(Q-TOF) LC/MS (LC/TOFMS를 이용한 생체시료의 내인성 대사체 분석법 개발)

  • Lee, In-Sun;Kim, Jin-Ho;Cho, Soo-Yeul;Shim, Sun-Bo;Park, Hye-Jin;Lee, Jin-Hee;Lee, Ji-Hyun;Hwang, In-Sun;Kim, Sung-Il;Lee, Jung-Hee;Cho, Su-Yeon;Choi, Don-Woong;Cho, Yang-Ha
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.388-394
    • /
    • 2010
  • Metabolomics aims at the comprehensive, qualitative and quantitative analysis of wide arrays of endogenous metabolites in biological samples. It has shown particular promise in the area of toxicology and drug development, functional genomics, system biology and clinical diagnosis. In this study, analytical technique of MS instrument with high resolution mass measurement, such as time-of-flight (TOF) was validated for the purpose of investigation of amino acids, sugars and fatty acids. Rat urine and serum samples were extracted by selected each solvent (50% acetonitrile, 100% acetonitrile, acetone, methanol, water, ether) extraction method. We determined the optimized liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) system and selected appropriated columns, mobile phases, fragment energy and collision energy, which could search 17 metabolites. The spectral data collected from LC/TOFMS were tested by ANOVA. Obtained with the use of LC/TOFMS technique, our results indicated that (1) MS and MS/MS parameters were optimized and most abundant product ion of each metabolite were selected to be monitorized; (2) with design of experiment analysis, methanol yielded the optimal extraction efficiency. Therefore, the results of this study are expected to be useful in the endogenous metabolite fields according to validated SOP for endogenous amino acids, sugars and fatty acids.

Analysis of dutasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 dutasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Jung, Ki-Kyung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.76-82
    • /
    • 2012
  • The determination and confirmation of dutasteride in human serum was performed by a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Beclomethasone as an internal standard (I.S.) was added to the serum and the mixed sample was pretreated by liquid-liquid extraction (LLE) with methyl tert-butyl ether (MTBE). The mass transitions of dutasteride and I.S. monitored in multiple reaction monitoring (MRM) were m/z 529.6${\rightarrow}$461.5 and m/z 409.3${\rightarrow}$391.2, respectively, and the retention times were 6.45 and 5.46 min, respectively. The calibration curve was linear in the concentration range of 0.5~30.0 ng/mL ($R^2$= 0.9999) and the limit of quantitation (LOQ) was found to be 0.5 ng/mL. The recovery of dutasteride was shown to be 66~72%. The intra-day assay precision and accuracy were in the range 3.5~5.5% and 85.7~89.9%, respectively, and the interday assay precision and accuracy were in the range 4.2~5.8% and 90.8~95.8%, respectively.

Detection of phenobarbital adulteration in dietary supplements: simultaneous analysis of 16 sedative-hypnotics and sleep-inducers by ultra-high-performance liquid chromatography with UV detection (UPLC-UV) and quadruple Orbitrap mass spectrometry (Q-Orbitrap-MS)

  • Lee, Ji Hyun;Choi, Ji Yeon;Park, Hanna;Min, Ah Young;Kim, Nam Sook;Park, Seong Soo;Park, Sung-Kwan;Kang, Ho-il
    • Analytical Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.24-34
    • /
    • 2019
  • The safety of food is occasionally questionable, as there have been some reports of products contaminated with illegal adulterants. In this study, the presence of 16 sedative-hypnotics and sleep inducers in dietary supplements was determined by ultra-high-performance liquid chromatography with UV detection (UPLC-UV) and quadruple Orbitrap mass spectrometry (Q-Orbitrap-MS). The UPLC method was validated, providing a linearity (R2) of more than 0.999, and LODs and LOQs that ranged from 0.2 to 0.5 and 0.6 to $1.5{\mu}g\;mL^{-1}$, respectively. The repeatabilities were 0.2-8.4 % (intra-day) and 0.3-4.5 % (inter-day), and the accuracies were 89.0-117.0 % (intra-day) and 87.8-111.9 % (inter-day). The mean recoveries of the spiked samples ranged from 98.7 to 107.3 %. The relative standard deviation (%RSD) of the stability was less than 2.4 %. Using the developed method, one sedative-hypnotic compound, phenobarbital, was detected in one of the nineteen samples tested. In addition, the major characteristic fragment ions of each target compound were confirmed using Q-Orbitrap-MS for higher accuracy. Monitoring the presence of these 16 sedative-hypnotics and sleep inducers in dietary supplements should be pursued in the interest of human health, and the results of this study confirmed that the developed method has value for this application.

Development and validation of an LC-MS/MS method for the simultaneous analysis of 26 anti-diabetic drugs in adulterated dietary supplements and its application to a forensic sample

  • Kim, Nam Sook;Yoo, Geum Joo;Kim, Kyu Yeon;Lee, Ji Hyun;Park, Sung-Kwan;Baek, Sun Young;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.35-47
    • /
    • 2019
  • In this study, high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was employed to detect 26 antidiabetic compounds in adulterated dietary supplements using a simple, selective method. The work presented herein may help prevent incidents related to food adulteration and restrict the illegal food market. The best separation was obtained on a Shiseido Capcell Pak(R) C18 MG-II ($2.0mm{\times}100mm$, $3{\mu}m$), which improved the peak shape and MS detection sensitivity of the target compounds. A gradient elution system composed of 0.1 % (v/v) formic acid in distilled water and methanol at a flow rate of 0.3 mL/min for 18 min was utilized. A triple quadrupole mass spectrometer with an electrospray ionization source operated in the positive or negative mode was employed as the detector. The developed method was validated as follows: specificity was confirmed in the multiple reaction monitoring mode using the precursor and product ion pairs. For solid samples, LOD ranged from 0.16 to 20.00 ng/mL and LOQ ranged from 0.50 to 60.00 ng/mL, and for liquid samples, LOD ranged from 0.16 to 20.00 ng/mL and LOQ ranged from 0.50 to 60.00 ng/mL. Satisfactory linearity was obtained from calibration curves, with $R^2$ > 0.99. Both intra and inter-day precision were less than 13.19 %. Accuracies ranged from 80.69 to 118.81 % (intra/inter-day), with a stability of less than 14.88 %. Mean recovery was found to be 80.6-119.0 % and less than 13.4 % RSD. Using the validated method, glibenclamide and pioglitazone were simultaneously determined in one capsule at concentrations of 1.52 and 0.53 mg (per capsule), respectively.

Analysis of Biurea Decomposed from Azodicarbonamide in Food Products by High Performance Liquid Chromatography Mass/Mass Spectrometry (LC/MS/MS를 이용한 식품 중 아조디카르본아미드 분해산물인 Biurea 함량 분석)

  • Lim, Ho-Soo;Pahn, Kyeong-Nyeo;Kim, Jun-Hyun;Jang, Gui-Hyeon;Moon, Gui-Im;Yang, Hyo-Jin;Park, Sung-Kwan;Park, Hae-Kyong;Kim, So-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.377-382
    • /
    • 2010
  • This study was conducted to establish a method to analyze biurea decomposed from azodicarbonamide in processed foods such as wheat flour and bread. New method was developed using high performance liquid chromatography mass/mass spectrometry to determine biurea in wheat flour and bakery products. The recovery rate was 94.3-112.5%. The limit of detection for biurea was 0.003 mg/kg, and the limit of quantification was 0.01 mg/kg. The monitoring results for biurea content using established methods showed that biurea was detected at 2.76 mg/kg in the azodicarbonamide-detected flour (detection rate, 2%). The detection rate in processed foods such as baked goods was 27% (16/59). The detection range was 0.19-18.01 mg/kg (average, 3.79 mg/kg). However, it was thought that the detection level was safe due to much lower values than the standard (45 mg/kg). As a result, the newly established biurea analytical method will contribute to the management of azodicarbonamide in processed foods such as wheat flour and bakery products.

Biomonitoring of Aflatoxin B1 Exposed by Herbal Medicine Intake (생약 복용에 따른 아플라톡신 B1의 인체모니터링 연구)

  • Lee, Jin-Hee;Ryu, Heui-Young;Kim, Hyun-Kyung;Kim, Do-Jung;Lee, Young-Joo;Jung, Su-Hee;Jang, Dong-Deuk;Kim, Hyung-Su;Hong, Yeon-Pyo;Yoon, Hae-Seong
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.2
    • /
    • pp.155-162
    • /
    • 2010
  • Aflatoxin $B_1$, a known human carcinogen, is the member of aflatoxin subfamily that is most frequently found in contaminated foods. Epidemiological studies have suggested that aflatoxins may be associated with human liver cancer and acute hepatitis. Recently it was reported that the traditional medical herbs sold in domestic markets are contaminated with aflatoxins. Long-term administration of these contaminated medicines could result in adverse health effects. Therefore, it is important to evaluate the levels of exposure to aflatoxin in people who ingest traditional herbal medicines. Blood samples were collected, before and after the herbal medicine intake, from 151 subjects who visited the hospital. The metabolite of aflatoxin $B_1$ in blood, aflatoxin $B_1$-albumin (aflatoxin $B_1$-lysine), is reportedly an appropriate internal exposure indicator, and its levels in the collected bloods were therefore analyzed using a liquid chromatography-mass spectrometry. The analytical method of aflatoxin $B_1$-lysine in blood was firstly optimized in Korea and the levels were detected below quantification limits (2 pg/mg albumin) in this study population. Consequently, the exposure levels of aflatoxin $B_1$ by ingestion of herbal medicines were low but it is important to monitor routinely due to the possibility of risk on the aflatoxin exposure.