Browse > Article
http://dx.doi.org/10.5806/AST.2019.32.1.24

Detection of phenobarbital adulteration in dietary supplements: simultaneous analysis of 16 sedative-hypnotics and sleep-inducers by ultra-high-performance liquid chromatography with UV detection (UPLC-UV) and quadruple Orbitrap mass spectrometry (Q-Orbitrap-MS)  

Lee, Ji Hyun (Division of Advanced Analysis, National Institute of Food and Drug Safety Evaluation, Ministry of Food & Drug Safety, Osong Health Technology Administration Complex)
Choi, Ji Yeon (Division of Advanced Analysis, National Institute of Food and Drug Safety Evaluation, Ministry of Food & Drug Safety, Osong Health Technology Administration Complex)
Park, Hanna (Division of Advanced Analysis, National Institute of Food and Drug Safety Evaluation, Ministry of Food & Drug Safety, Osong Health Technology Administration Complex)
Min, Ah Young (Division of Advanced Analysis, National Institute of Food and Drug Safety Evaluation, Ministry of Food & Drug Safety, Osong Health Technology Administration Complex)
Kim, Nam Sook (Division of Advanced Analysis, National Institute of Food and Drug Safety Evaluation, Ministry of Food & Drug Safety, Osong Health Technology Administration Complex)
Park, Seong Soo (Division of Advanced Analysis, National Institute of Food and Drug Safety Evaluation, Ministry of Food & Drug Safety, Osong Health Technology Administration Complex)
Park, Sung-Kwan (Division of Advanced Analysis, National Institute of Food and Drug Safety Evaluation, Ministry of Food & Drug Safety, Osong Health Technology Administration Complex)
Kang, Ho-il (Division of Advanced Analysis, National Institute of Food and Drug Safety Evaluation, Ministry of Food & Drug Safety, Osong Health Technology Administration Complex)
Publication Information
Analytical Science and Technology / v.32, no.1, 2019 , pp. 24-34 More about this Journal
Abstract
The safety of food is occasionally questionable, as there have been some reports of products contaminated with illegal adulterants. In this study, the presence of 16 sedative-hypnotics and sleep inducers in dietary supplements was determined by ultra-high-performance liquid chromatography with UV detection (UPLC-UV) and quadruple Orbitrap mass spectrometry (Q-Orbitrap-MS). The UPLC method was validated, providing a linearity (R2) of more than 0.999, and LODs and LOQs that ranged from 0.2 to 0.5 and 0.6 to $1.5{\mu}g\;mL^{-1}$, respectively. The repeatabilities were 0.2-8.4 % (intra-day) and 0.3-4.5 % (inter-day), and the accuracies were 89.0-117.0 % (intra-day) and 87.8-111.9 % (inter-day). The mean recoveries of the spiked samples ranged from 98.7 to 107.3 %. The relative standard deviation (%RSD) of the stability was less than 2.4 %. Using the developed method, one sedative-hypnotic compound, phenobarbital, was detected in one of the nineteen samples tested. In addition, the major characteristic fragment ions of each target compound were confirmed using Q-Orbitrap-MS for higher accuracy. Monitoring the presence of these 16 sedative-hypnotics and sleep inducers in dietary supplements should be pursued in the interest of human health, and the results of this study confirmed that the developed method has value for this application.
Keywords
Sedative-Hypnotics; Adulterants; UPLC-UV; Q-Orbitrap-MS; Method Validation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 L. J. Greenfield, S. H. Zaman, M. L. Sutherland, S. C. Lummis, M. I. Niemeyer, E. A. Barnard, and R. L. Macdonald, Neuropharmacology, 42, 502-521 (2002).   DOI
2 C. Gottesmann, Neuroscience, 111, 231-239 (2002).   DOI
3 J. Wang, B. Chen, and S. Yao, Food addit. Contam., 25, 822-830 (2008).   DOI
4 Z. Wang, J. Zhang, and Y. Zhang, J. Chin. Mass Spec. Soc., 30, 282-286 (2009).
5 A. Yan, X. Li, C. Xi, L. Zhang, S. Xia, G. Wang, B. Tang, and Z. Mu, Chinese J. Anal. Chem., 41, 509-516 (2013).   DOI
6 E. Deconinck, P. Y. Sacre, P. Courselle, and J. O. De Beer, J. Chromatogr. Sci., 51, 791-806 (2013).   DOI
7 AOAC Official Methods of Analysis. Internationalconference on harmonization of harmonized tripartiteguideline, validation of analytical procedures: text andmethodology.
8 AOAC International, Rockville, MD (2005).
9 ICH International conference on Harmonization. Harmonized tripartite guideline, validation of analyticalprocedures: text and methodology Q2
10 (R1). European Medicines Agency (EUMA), London, UK .
11 A, El-Gindy, Il Farmaco, 60, 745 (2005).   DOI
12 R. A. Menck, D. S. De Lima, S. C. Seulin, V. Leyton, C. A. Pasqualucci, D. R. Munoz, M. D. Osseltore, M. Yonamine, J. Sep. Sci., 35, 3361-3368 (2012).   DOI
13 X. Zhang, Z. Lin, J. Li, Z. Huang, Y. Rao, H. Liang, J. Yan, and F. Zheng. Drug Testing and Analysis, 9, 588-595 (2017).   DOI
14 Q. Gao, B. Che, Z. Zhang, H. Dai, and H. Guo, J. Chin. Pharm. Univ., 39, 142-146 (2008).   DOI
15 B. Zhu, Z. Zhao, Z. Wang, Q. Xue, and L. Zhao, Chin. J. Pharm. Anal., 30, 745-751 (2010).
16 J. Liu, L. Xiao, X. Guan, Y. Xiong, T. Wang, and J. Li, Chin. J. Pharm. Anal., 31, 376-379 (2011).
17 P. Jin, Z. Wang, W. Wang, D. Zou, J. Ma, and X. Hu, Chin Pharm. J., 47, 462-466 (2012).