• Title/Summary/Keyword: mass concrete

Search Result 884, Processing Time 0.032 seconds

A Study on the Control of Thermal Crack of the Mat Foundation (매트기초의 온도균열 제어에 관한 연구)

  • 이도범;김효락;박지훈;최일호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.305-308
    • /
    • 2003
  • Recently, a structure has been large and high under the improvement of construction technique. So, mass concrete constructions that a mat foundation thickness of structure is over 80cm have been many. Also, in the reason of high strength of concrete, a matter of thermal crack became an important task to be solved. In this study, we executed temperature and stress analysis of mat foundation. And we evaluated quantitatively about the possibility of thermal crack by using hydration heat analysis program. Because of this analysis technique, we could control skilfully the quality of mat foundation in a construction.

  • PDF

Frequency domain analysis of concrete arch dams by decoupled modal approach

  • Lotfi, Vahid
    • Structural Engineering and Mechanics
    • /
    • v.21 no.4
    • /
    • pp.423-435
    • /
    • 2005
  • A modal approach is proposed for dynamic analysis of concrete arch dam-reservoir systems in frequency domain. The technique relies on mode shapes extracted by considering the symmetric parts of total mass and stiffness matrices. Based on this method, a previously developed program is modified, and the response of Morrow Point arch dam is studied for various conditions. The method is proved to be very effective and it is an extremely convenient modal technique for dynamic analysis of concrete arch dams.

Light Emotion Friendly Concrete With Transparent Materials (투명재료를 이용한 빛 감성 친화형 콘크리트)

  • Kim, Byoungil
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.40-41
    • /
    • 2015
  • The purpose of this study is to develop advaced furture type of concrete which utilizes transpart plastic types of fiber replacing previously used high price optical fiber and porous type of steel mold to induce its mass production. New type of concrete solved problems of construction and economy can make it easily their application to construction market.

  • PDF

Strength Development of Concrete Using Blast-Furnace Slag Cement under Various Curing Temperatures (양생온도변화에 따른 고로슬래그 시멘트를 사용한 콘크리트의 강도증진 성상)

  • 윤기원;유호범;한민철;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.163-166
    • /
    • 1999
  • In this paper, strength development of concrete using blast-furnace slag cement(BSC) and ordinary portland cement(OPC) are discussed under varius W/C and curing temperatures. According to the experimental results, strength development of BSC concrete is lower than that of OPC concrete in low temperature at early age and maturity. In high curing temperature, BSC concrete has higher strength development than that of low temperature regardless of the elapse of age and maturity. BSC has much effect on the strength development of concrete at the condition of mass concrete, hot weather concreting and the concrete products with the steam curing, which is influenced by high temperature.

  • PDF

An Experimental Study on the Measurement of Temperature and Thermal Stress of Wall Type Mass Concrete Structure (벽체형 매스콘크리트구조물의 온도 및 온도응력측정에 관한 실험적 연구)

  • 강석화;이용호;정한중;박칠림
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.173-177
    • /
    • 1995
  • Thermal cracks ard occured when thermal stress due to the hydration of cement exceeds the tensile strength of concrete. Since cracking causes poor durability of concrete, the effect of thermal cracking should be included for the desing and construction of massive concrete structures. In this study, an experiments are performed for the investigation of time dependent temperature and thermal stress of massive concrete structure at early ages. In order to measure temperatures and thermal stresses, concrete stress meter, embedded strain meter, non-stress meter, and thermocouples are used. Based on the analyses of measured thermal stress data, measured values by concrete stress meter are more reliable than those by embedded strain meter and non-stress meter, And measured values by concrete stress meter are compared with the calculated values by FEM program developed by DICT (DWTS2D). Calculated values by DWTS2D show good agreement with measured values.

  • PDF

An Experimental Study on Prediction of Compressive Strength of the In situ Mass Concrete with Fly-ash (플라이애쉬를 혼입한 현장타설 매스콘크리트의 압축강도 추정에 관한 실험적 연구)

  • Khil, Bae-Su;Chae, Young-Suk;Nam, Jae-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.1
    • /
    • pp.163-169
    • /
    • 1999
  • The object of this study is to compare properties of massive fly-ash concrete with plain concrete. Two concrete mixtures comprising two batch each $1.0m^3$ in volume, were made from ready mixed concrete batch plant. The water-to-cementitious materials ratio was kept constant at 51.4%. Therefore, massive concrete specimen($W800{\times}D800{\times}H800mm$) was cast from ready mixed concrete to analyze history of temperature and core strength properties. Bleeding, time of slump loss and time of setting of the fresh concrete were measured. In order to estimate the properties of massive fly-ash concrete in hardened concrete, non-destructive tests such as rebound hardness, ultrasonic pulse velocity and maturity were performed and analyzed.

  • PDF

A Study on the Optimum Mix Proportion of the Mass Concrete Designed as Massive and Deep Structure

  • Kwon Yeong-Ho;Lee Hwa-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.2 s.86
    • /
    • pp.293-302
    • /
    • 2005
  • This study describes data from determination of the optimum mix proportion and site application of the mass concrete placed in bottom slab and side wall having a large depth and section as main structures of LNG in-ground tank. This concrete requires low heat hydration, excellent balance between workability and consistency because concreting work of LNG in-ground tank is usually classified by under-pumping, adaptation of longer vertical and horizontal pumping line than ordinary pumping condition. For this purpose, low heat Portland cement and lime stone powder as cementitious materials are selected and design factors including unit cement and water content, water-binder ratio, fine aggregate ratio and adiabatic temperature rising are tested in the laboratory and batch plant. As experimental results, the optimum unit cement and water content are selected under $270kg/m^3$ and $l55{\~}l60 kg/m^3$ separately to control adiabatic temperature rising below $30^{\circ}C$ and to improve properties of the fresh and hardened concrete. Also, considering test results of the confined water ratio($\beta$p) and deformable coefficient(Ep), $30\%$ of lime stone powder by cement weight is selected as the optimum replacement ratio. After mix proportions of 5cases are tested and compared the adiabatic temperature rising($Q^{\infty}$, r), tensile and compressive strength, modulus of elasticity, teases satisfied with the required performances are chosen as the optimum mix design proportions of the side wall and bottom slab concrete. $Q^{\infty}$ and r are proved smaller than those of another project. Before application in the site, properties of the fresh concrete and actual mixing time by its ampere load are checked in the batch plant. Based on the results of this study, the optimum mix proportions of the massive concrete are applied successfully to the bottom slab and side wall in LNG in-ground tank.

The Reduction of Maximum Hydration Temperature in Cement Paste Using Calcium Silicate Hydrates and Glucose (칼슘실리케이트 수화물과 포도당을 이용한 시멘트 페이스트의 최대 수화온도 저감)

  • Moon, Hoon;Kim, Hyeong-Keun;Ryu, Eun-Ji;Jin, Eun-Ji;Chung, Chul-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.3
    • /
    • pp.265-272
    • /
    • 2015
  • In this study, a method to reduce temperature rise due to hydration in mass concrete is investigated. It is to use retarder (glucose) for reducing heat of hydration and to use calcium silicate hydrate (C-S-H) for compensating the retardation effect due to its role as a nucleation seed. For this purpose, the temperature rise of cement paste due to hydration was measured and the effect of using both C-S-H and glucose on setting and 28-day compressive strength of mortar specimens was investigated. According to the experimental results, using C-S-H and glucose caused the reduction in the maximum temperature but accelerated the time to reach the maximum temperature compared to that of retarded cement paste using glucose. In addition, using C-S-H and glucose did not show significant effect on 28-day compressive strength of mortar specimens, indicating that the method shown in this study can be a successful alternative to control maximum temperature rise in mass concrete.

Optimum Binder Ratio of Mass Concrete for LNG Tank (LNG저장시설 적용을 위한 매스콘크리트 최적 결합재 혼입율 검토)

  • Kim, Young-Jin;Park, Sang-Jun;Kim, Kyoung-Min;Lee, Eui-Bae
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.240-245
    • /
    • 2013
  • The optimum binder ratio of the low heat mass concrete for LNG tank was evaluated in the present study. Three types of binder such as OPC I, ground granulated blast-furnace slag powder were mixed and were used. Also fine particle cement and activator were used to raise an early age strength development and ground limestone was used to reduce the cost. As a result of the study, mix ratio II (30:30:40) was suitable for Bottom Center and mix ratio III(40:30:30) was suitable for Roof based on compressive strength and semi-adiabatic temperature.