• Title/Summary/Keyword: mass attenuation coefficient

Search Result 67, Processing Time 0.034 seconds

DEVELOPMENT OF POINT KERNEL SHIELDING ANALYSIS COMPUTER PROGRAM IMPLEMENTING RECENT NUCLEAR DATA AND GRAPHIC USER INTERFACES

  • Kang, Sang-Ho;Lee, Seung-Gi;Chung, Chan-Young;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.215-224
    • /
    • 2001
  • In order to comply with revised national regulationson radiological protection and to implement recent nuclear data and dose conversion factors, KOPEC developed a new point kernel gamma and beta ray shielding analysis computer program. This new code, named VisualShield, adopted mass attenuation coefficient and buildup factors from recent ANSI/ANS standards and flux-to-dose conversion factors from the International Commission on Radiological Protection (ICRP) Publication 74 for estimation of effective/equivalent dose recommended in ICRP 60. VisualShieid utilizes graphical user interfaces and 3-D visualization of the geometric configuration for preparing input data sets and analyzing results, which leads users to error free processing with visual effects. Code validation and data analysis were performed by comparing the results of various calculations to the data outputs of previous programs such as MCNP 4B, ISOSHLD-II, QAD-CGGP, etc.

  • PDF

Experimental Verification of Analysis Model of the Shadow Mask with Damping Wires (댐핑 와이어를 갖는 새도우 마스크의 해석모델에 대한 실험적 검증)

  • 김성대;김원진;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.460-465
    • /
    • 2002
  • The nonlinear vibration of the CRT shadow mask is analyzed in consideration of the V-shaped tension distribution and the effect of wire impact damping. The reduced order FEM model of the shadow mask is obtained from dynamic condensation for the mass and stiffness matrices. Damping wire is modeled using the lumped parameter method to effectively describe its contact interactions with the shadow mask. The nonlinear contact-impact model is composed of spring and damper elements, of which parameters are determined from the Hertzian contact theory and the restitution coefficient, respectively. The analysis model of the shadow mask with damping wires is experimentally verified through impact tests of shadow masks performed in a vacuum chamber. Using the validated analysis model of the shadow mask with damping wires, the‘design of experiments’technique is applied to search fur the optimal damping wire configuration so that the vibration attenuation of the shadow mask is maximized.

  • PDF

Nordic research and development cooperation to strengthen nuclear reactor safety after the Fukushima accident

  • Linde, Christian;Andersson, Kasper G.;Magnusson, Sigurdur M.;Physant, Finn
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.647-653
    • /
    • 2019
  • A comprehensive study of photon interaction features has been made for some alloys containing Pd and Ag content to evaluate its possible use as alternative gamma radiations shielding material. The mass attenuation coefficient (${\mu}/{\rho}$) of the present alloys was measured at various photon energies between 81 keV - 1333 keV utilizing HPGe detector. The measured ${\mu}/{\rho}$ values were compared to those of theoretical and computational (MCNPX code) results. The results exhibited that the ${\mu}/{\rho}$ values of the studied alloys are in same line with results of WinXCOM software and MCNPX code results at all energies. Moreover, Pd75/Ag25 alloy sample has the maximum radiation protection efficiency (about 53% at 81 keV) and lowest half value layer, which shows that Pd75/Ag25 has superior gamma radiation shielding performance among the compared other alloys.

An extensive investigation on gamma ray shielding features of Pd/Ag-based alloys

  • Agar, O.;Sayyed, M.I.;Akman, F.;Tekin, H.O.;Kacal, M.R.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.853-859
    • /
    • 2019
  • A comprehensive study of photon interaction features has been made for some alloys containing Pd and Ag content to evaluate its possible use as alternative gamma radiations shielding material. The mass attenuation coefficient (${\mu}/{\rho}$) of the present alloys was measured at various photon energies between 81 keV-1333 keV utilizing HPGe detector. The measured ${\mu}/{\rho}$ values were compared to those of theoretical and computational (MCNPX code) results. The results exhibited that the ${\mu}/{\rho}$ values of the studied alloys are in the same line with results of WinXCOM software and MCNPX code results at all energies. Moreover, Pd75/Ag25 alloy sample has the maximum radiation protection efficiency (about 53% at 81 keV) and lowest half value layer, which shows that Pd75/Ag25 has superior gamma radiation shielding performance among the other compared alloys.

Ground Vibration in Tunnelling by Blasting and its Effect on Surface Structures (터널굴착이 지상구조물에 미치는 영향평가 및 발파지침설계)

  • 신희순;한공창;류창하;신중호;박연준;최영학
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.463-470
    • /
    • 2000
  • In tunnel excavation by blast beneath the surface structures in urban area, the characteristics of ground vibration induced by blast and its influence on surface structures are analyzed by the field test and the numerical analysis on dynamic behaviors of the structure. According to the field test on the propagating characteristics of blast vibration through the rock mass and the concrete foundation pile. the attenuation index of peak particle velocity with distance shows the range of 1.7∼2.0 for the rock mass and the range of 2.0∼2.3 for the concrete pile. This shows that the blast vibration reduces more rapidly in the concrete pile. It is known from the numerical analysis on dynamic behavior of the structure that the coefficient of response, velocity ratio of structure response to input wave, is different according to the story of the structure. It can be said from this research that the characteristics of the ground vibration and the dynamic behavior of the structure should be well evaluated and be considered as important factors for safe blasting design especially in underground excavation at shallow depth in urban area.

  • PDF

Determination of Air-dry Density of Wood with Polychromatic X-ray and Digital Detector

  • Kim, Chul-Ki;Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.836-845
    • /
    • 2017
  • Gravimetric method is usually used to evaluate air-dry density, which is governing physical or mechanical properties of wood. Although it had high evaluation accuracy, the method is time consuming process. Thus, this study was conducted to estimate air-dry density of wood with high accuracy by using polychromatic X-ray and digital detector as alternative of gravimetric method. To quantify polychromatic X-ray projection for evaluating air-dry density, Lambert-Beer's law with the integral value of probability function was used. The integral value was used as weighting factor in the law, and it was determined by conducting simple test at various penetration depths and tube voltage. Mass attenuation coefficient (MAC) of wood also calculated by investigating polychromatic X-ray projection according to species, penetration depth and tube voltage. The species had not an effect on change of MAC. Finally, an air-dry density of wood was estimated by applying the integral value, MAC and Lambert-Beer's law to polychromatic X-ray projection. As an example, the relation of the integral value (${\alpha}$) according to penetration depth (t, cm) at tube voltage of 35 kV was ${\alpha}=-0.00091t{\times}0.0184$ while the regression of the MAC (${\mu}$, $cm^2/g$) was ${\mu}=0.5414{\exp}(-0.0734t)$. When calculation of root mean squared error (RMSE) was performed to check the estimation accuracy, RMSE at 35, 45 and 55 kV was 0.010, 0.013 and $0.009g/cm^3$, respectively. However, partial RMSE in relation to air-dry density was varied according to tube voltage. The partial RMSE below air-dry density of $0.41g/cm^3$ was $0.008g/cm^3$ when tube voltage of 35 kV was used. Meanwhile, the partial RMSE above air-dry density of $0.41g/cm^3$ decreased as tube voltage increased. It was conclude that the accuracy of estimation with polychromatic X-ray and digital detector was quite high if the integral value and MAC of wood were determined precisely or a condition of examination was chosen properly. It was seemed that the estimation of air-dry density by using polychromatic X-ray system can supplant the gravimetric method.

Development of Portable X-ray CT System I - Evaluation of Wood Density using X-ray Radiography - (현장 적용이 가능한 X선 CT 시스템 개발 I - X선 촬영법을 이용한 목재의 밀도 측정 -)

  • Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.15-22
    • /
    • 2006
  • ln order to manage efficiently many ancient wooden buildings, which have been preserved as cultural properties in Korea, the internal state of wood members should be evaluated exactly and periodically by a NDE (non-destructive evaluation) method. A research project was planned to develop an X-ray CT (computed tomography) system as a NDE method for wood, which could be easily applied in field. This paper includes the first part of this project. First of all, to establish a measuring procedure of wood density using X-ray radiography, the correlation between X-ray intensity and the film brightness was evaluated. Also, initial X-ray intensity was quantified with various radiate conditions controlled by the tube voltage and tube current. And then, the effects of density, annual ring angle, and thickness on the mass attenuation coefficient of wood were examined. Finally, Beer's law was modified with the above results and adopted to calculate the density of wood. As a result of this study, the measuring procedure of wood density was established using a portable soft X-ray device and this procedure was verified with some small wood specimens. This results will he used valuably for the following researches to develop a portable X-ray CT system.

Determination of X-ray and gamma-ray shielding capabilities of recycled glass derived from deteriorated silica gel

  • P. Sopapan;O. Jaiboon;R. Laopaiboon;C. Yenchai;C. Sriwunkum;S. Issarapanacheewin;T. Akharawutchayanon;K. Yubonmhat
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3441-3449
    • /
    • 2023
  • We determined the radiation shielding properties for 10CaO-xPbO-(90-x) deteriorated silica gel (DSG) glass system (x = 20, 25, 30, 35, 40, and 45 mol.%). The mass attenuation coefficient (MAC) has been estimated at photon energies of 74.23, 97.12, 122, 662, 1173, and 1332 keV using a narrow beam X-ray attenuation and transmission experiment, the XCOM program, and a PHITS simulation. The obtained MAC values were applied to estimate the half value layer (HVL), mean free path (MFP), effective atomic number, and effective electron density. Results show that the MAC value of the studied glasses ranges between 0.0549 and 1.4415 cm2/g, increases with the amount of PbO, and decreases with increasing photon energy. The HVL and MFP values decrease with increasing PbO content and increase with increasing photon energy. The recycled glass, with the addition of PbO content (20-45 mol.%), exhibited excellent radiation shielding capabilities compared to standard barite and ferrite concretes and some glass systems. Moreover, the experimental radiation shielding parameters agree with the XCOM and PHITS values. This study suggests that this new waste-recycled glass is an effective and cost-saving candidate for X-ray and gamma-ray shielding applications.

Correlation between the concentration of TeO2 and the radiation shielding properties in the TeO2-MoO3-V2O5 glass system

  • Y. Al-Hadeethi ;M.I. Sayyed
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1218-1224
    • /
    • 2023
  • We investigated the radiation shielding competence for TeO2-V2O5-MoO3 glasses. The Phy-X software was used to report the radiation shielding parameters for the present glasses. With an increase in TeO2 and MoO3 content, the samples' linear attenuation coefficient improves. However, at low energies, this change is more apparent. At low energy, the present samples have an effective atomic number (Zeff) that is relatively high (in order of 16.17-24.48 at 0.347 MeV). In addition, the findings demonstrated that the density of the samples is a very critical factor in determining the half value layer (HVL). The minimal HVL for each sample can be found at 0.347 MeV and corresponds to 1.776, 1.519, 1.391, 1.210 and 1.167 cm for Te1 to Te5 respectively. However, the highest HVL of these glasses is recorded at 1.33 MeV, which corresponds to 3.773, 3.365, 3.218, 2.925 and 2.908 cm respectively. The tenth value layer results indicate that the thickness of the specimens needs to be increased in order to shield the photons that have a greater energy. Also, the TVL results demonstrated that the sample with the greatest TeO2 and MoO3 concentration has a higher capacity to attenuate photons.

Investigation of photon, neutron and proton shielding features of H3BO3-ZnO-Na2O-BaO glass system

  • Mhareb, M.H.A.;Alajerami, Y.S.M.;Dwaikat, Nidal;Al-Buriahi, M.S.;Alqahtani, Muna;Alshahri, Fatimh;Saleh, Noha;Alonizan, N.;Saleh, M.A.;Sayyed, M.I.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.949-959
    • /
    • 2021
  • The current study aims to explore the shielding properties of multi-component borate-based glass series. Seven glass-samples with composition of (80-y)H3BO3-10ZnO-10Na2O-yBaO where (y = 0, 5, 10, 15, 20, 25 and 30 mol.%) were synthesized by melt-quench method. Various shielding features for photons, neutrons, and protons were determined for all prepared samples. XCOM, Phy-X program, and SRIM code were performed to determine and explain several shielding properties such as equivalent atomic number, exposure build-up factor, specific gamma-ray constants, effective removal cross-section (ΣR), neutron scattering and absorption, Mass Stopping Power (MSP) and projected range. The energy ranges for photons and protons were 0.015-15 MeV and 0.01-10 MeV, respectively. The mass attenuation coefficient (μ/ρ) was also determined experimentally by utilizing two radioactive sources (166Ho and 137Cs). Consistent results were obtained between experimental and XCOM values in determining μ/ρ of the new glasses. The addition of BaO to the glass matrix led to enhance the μ/ρ and specific gamma-ray constants of glasses. Whereas the remarkable reductions in ΣR, MSP, and projected range values were reported with increasing BaO concentrations. The acquired results nominate the use of these glasses in different radiation shielding purposes.