• Title/Summary/Keyword: masonry building

Search Result 196, Processing Time 0.024 seconds

Ambient vibration tests on a 19 - story asymmetric steel building

  • Shakib, H.;Parsaeifard, N.
    • Structural Engineering and Mechanics
    • /
    • v.40 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • Ambient vibration tests were carried out to evaluate the dynamic properties of an asymmetric steel building with semi-rigid connections. The test case has many non-structural elements, constructed in the city of Tehran (Iran). The tests were conducted to obtain natural frequencies, mode shapes and damping ratio of the structure and then Fourier transform were used to analyze the velocity records obtained from the tests. The first and second natural periods of the building were obtained as 1.37 s and 1.28 s through the test and damping ratio for the first mode was calculated as 0.047. However, Natural periods obtained from finite element model have higher values from those gained from ambient vibration. Then the model was calibrated by modeling of the in-fill masonry panels at their exact locations and considering the boundary conditions by modeling two blocks near the block No. 3, but the differences were existed. These differences may be due to some hidden stiffness of nonstructural elements in the low range of elastic behavior, showing the structure stiffer than it is in reality.

A Study on the Slope Stability Assessment of Seokguram Region in Gyeongju (경주 석굴암 주변 비탈면의 안정성에 관한 연구)

  • Lee, Kwang-Wu;Kim, Seung-Hyun;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.139-149
    • /
    • 2017
  • The maintenance, repair, and reinforcement projects and structural stability assessments of Seokguram have primarily focused on examining the condition of stone members of Seokguram and the concrete dome structure for Seokguram. However, a 12 m-high rock slope located behind Seokguram raises a concern of slope failure and rockfall, which may reduce stability of Seokguram. It is also unclear whether the soil slopes and masonry wall at the side and the front of Seokguram have sufficient long-term stability against localized heavy rains and earthquakes, which have been frequent in recent years. The present study investigates the ground and the slopes around Seokguram using detailed field survey to identify geographical and geological risk factors, and assess structural stability of the exposed rock mass behind and the slope in front of Seokguram and the masonry wall using stability analysis.

Improvement on the Non-standardized Name Use of Chinese Granite for Korean Building Constructions (건축공사용 중국산 화강석의 명칭혼란 개선방안)

  • Kim, Jae-Yeob;Lee, Ung-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.1
    • /
    • pp.81-87
    • /
    • 2015
  • The purpose of this study is to analyze the problem of confusing the names of Chinese granite used in Korean construction work and suggest the improvement plans for them. Interviews of the experts from the stone company, studies on the existing research literature, and analyses of construction work documents of the 23 construction works which used Chinese granite were carried out to analyze the real condition of name confusion of granite stone. In the analytical result of the real condition, name confusion was classified into 4 types and problems derived from it were done into 4 ones. An additional survey was carried out targeting 34 masonry experts to draw the improvement plans based on the analytical results of the real condition of name confusion. The results show that the most fundamental solution is to continue to make efforts to use exact names when main agents related to construction works communicate with each other regarding Chinese granite stone and the process to make out construction contract documents.

Analysis of Damping Performance of Hysteretic Dampers of Buckling restrained Braced Type According to eccentricity of school buildings with Torsional irregularities (비틀림 비정형을 가지는 학교건물의 편심율에 따른 좌굴방지가새형 이력댐퍼의 제진성능분석)

  • Kim, Yu-Seong;Lee, Joon-Ho;Kim, Gee-Chul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.2
    • /
    • pp.37-44
    • /
    • 2023
  • In the case of a school building, even though it is a regular structure in terms of plan shape, if the masonry infill wall acts as a lateral load resisting element, it can be determined as a torsionally irregular building. As a result, the strength and ductility of the structure are reduced, which may cause additional earthquake damage to the structure. Therefore, in this study, a structure similar to a school building with torsional irregularity was selected as an example structure and the damping performance of the PC-BRB was analyzed by adjusting the eccentricity according to the amount of masonry infilled wall. As a result of nonlinear dynamic analysis after seismic reinforcement, the torsional irregularity of each floor was reduced compared to before reinforcement, and the beams and column members of the collapse level satisfied the performance level due to the reduction of shear force and the reinforcement of stiffness. The energy dissipation of PC-BRB was similar in the REC-10 ~ REC-20 analytical models with an eccentricity of 20% or less. REC-25 with an eccentricity of 25% was the largest, and it is judged that it is effective to combine and apply PC-BRB when it has an eccentricity of 25% or more to control the torsional behavior.

The Elevator, the Iron Skeleton Frame, and the Early Skyscrapers: Part 2

  • Larson, Gerald R.
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.1
    • /
    • pp.17-41
    • /
    • 2020
  • In Part One, I documented the evolution of the use of the elevator and the iron frame to build ever-taller buildings that would eventually be called "skyscrapers," to offset the ever-increasing cost of Manhattan real estate. By the start of the Great Depression of the 1870s in 1873, New York architects had erected two ten-storied skyscrapers. In Part Two I document the major events, designers, and buildings in New York, Chicago, and other American cities that eventually culminated in the ability to erect 20 story skyscrapers by 1890.

A Study on the Planning Characteristics of Passive House by the Building Structural Types in Foreign Cases (해외 패시브하우스의 건축구조유형별 계획특성 연구)

  • Yang, Jung-Pil
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.15-20
    • /
    • 2013
  • The purpose of this study is to analyze the planning characteristics of passive house by the building structural types in foreign cases. The interests and demands about passive house have been increased, and various building structural types and design methods have been attempted for passive house in Korea. But domestic research results and development experiences about passive house were lack. The results of this study are as follows; First, in terms of energy performance, insulation performance, airtightness, there are not significant differences at the 95% confidence level by the structural types of passive house. Second, in terms of the types of insulation materials, there are significant differences at the 95% confidence level by the structural types of passive house. Third, in principle there is no need of traditional heating facility in passive houses, but in practice traditional heating facilities are used additionally in about half of survey cases for the comfort of occupants.

The Management Method for Preventing Frequent Defect about Each Inspection Part from The Data Analysis of Pre-qualification of Residential Building Reconstruction (주택 재건축 예비평가 자료분석을 통한 분야별 주요결함 발생현황 및 유지관리방안 고찰)

  • Bae, Cheol-Hak;Lee, Sung-Ok;Ji, Myoung-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.71-80
    • /
    • 2010
  • The purpose of this study is to classify defects of the residential building by analyzing the defect specified by prequalification of residential building reconstruction and to suggest the solution of the problem which can be arisen during each stage of plan, construction and maintenance. By sorting the main defects which is specified by pre-qualification of residential building reconstruction for three years from August 2006 to August 2009 into 4 catagories and analyzing the cause of the defects, we draw the way of maintenance to prevent the defects and make pleasant residential environment. The reason for the frequent defects from residential building is mainly deterioration. It occured on the finishing more than on the structure, which means that residents can find defects easier on the finishing than the structure and clear the demand for repair. The result of analyzing of pre-qualification of residential building reconstruction is that the defects mostly caused small, masonry constructed and lower apartment. The apartment which is not into legal right for maintenance naturally have more defects than the others. In conclusion, it is necessary to establish a law of obligation duty of the maintenance of small apartment.

Application of meta-model based parameter identification of a seismically retrofitted reinforced concrete building

  • Yu, Eunjong
    • Computers and Concrete
    • /
    • v.21 no.4
    • /
    • pp.441-449
    • /
    • 2018
  • FE models for complex or large-scaled structures that need detailed modeling of structural components are usually constructed using commercial analysis softwares. Updating of such FE model by conventional sensitivity-based methods is difficult since repeated computation for perturbed parameters and manual calculations are needed to obtain sensitivity matrix in each iteration. In this study, an FE model updating procedure avoiding such difficulties by using response surface (RS) method and a Pareto-based multiobjective optimization (MOO) was formulated and applied to FE models constructed with a commercial analysis package. The test building is a low-rise reinforced concrete building that has been seismically retrofitted. Dynamic properties of the building were extracted from vibration tests performed before and after the seismic retrofits, respectively. The elastic modulus of concrete and masonry, and spring constants for the expansion joint were updated. Two RS functions representing the errors in the natural frequencies and mode shape, respectively, were obtained and used as the objective functions for MOO. Among the Pareto solutions, the best compromise solution was determined using the TOPSIS (Technique for Order of Preference by Similarity to Ideal Solution) procedure. A similar task was performed for retrofitted building by taking the updating parameters as the stiffness of modified or added members. Obtained parameters of the existing building were reasonably comparable with the current code provisions. However, the stiffness of added concrete shear walls and steel section jacketed members were considerably lower than expectation. Such low values are seemingly because the bond between new and existing concrete was not as good as the monolithically casted members, even though they were connected by the anchoring bars.

Fragility Analysis of RC Moment Resisting Frame with Masonry Infill Walls (비내력벽을 가진 RC모멘트저항골조의 취약도 해석)

  • Ko, Hyun;Park, Yong-Koo;Lee, Dong-Guen
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.4
    • /
    • pp.355-362
    • /
    • 2009
  • Many of residential buildings, which have pilotis in lower stories to meet the architectural needs, are recently constructed in Korea. Usually, infill walls located in the upper stories of these buildings may cause a soft first story, which is very weak from the earthquake resistance. In the design of the buildings, the infill walls of upper stories are usually considered as non-structural elements and thus they are not included in the analytical model. However, the infill walls may affect the seismic behavior of the residential buildings. Therefore, the differences in seismic behaviors of RC buildings with and without masonry infill walls are required to be investigated. In this study, seismic fragility analyses were performed for masonry infilled low-rise RC moment-resisting frames. And seismic behaviors of RC moment-resisting frame with/without masonry infill walls were evaluated. Two types of structural system with the same frame and different allocation of infill walls are used to evaluate the influence of masonry infill walls on seismic behavior of RC moment-resisting frames. The infill walls were modeled as bi-equivalent diagonal struts. The fragility analyses show that the seismic performance of RC moment-resisting frames with soft story is below the desirable building seismic performance level recommended by current seismic codes, indicating high vulnerability of RC moment-resisting frames with soft story.

A Study on the Response Modification Factor of Unreinforced masonry Buildings (비보강 조적조 건물의 반응 수정 계수에 관한 연구)

  • 정상훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.265-272
    • /
    • 1999
  • there is no earthquake resistant design code for the unreinforced masonary(URM) buildings in Korea. But it does not mean that all URM buldings in Korea is safe under the possible extent of an earthquake. The purpose of this study is in the inelastic analysis of unreinforced masonary walls with many different types of openings and carry out their ductilities an strengths, response modification factor of each wall has been compared and the most appropriate response modification factor for URM building in Korea has been proposed.

  • PDF