• Title/Summary/Keyword: marA

Search Result 861, Processing Time 0.025 seconds

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

The improvement of ginsenoside accumulation in Panax ginseng as a result of γ-irradiation

  • Kim, Dong Sub;Song, Mira;Kim, Sun-Hee;Jang, Duk-Soo;Kim, Jin-Baek;Ha, Bo-Keun;Kim, Sang Hoon;Lee, Kyung Jun;Kang, Si-Yong;Jeong, Il Yun
    • Journal of Ginseng Research
    • /
    • v.37 no.3
    • /
    • pp.332-340
    • /
    • 2013
  • In this study, gamma rays were used to irradiate embryogenic calli induced from cotyledon explants of Panax ginseng Meyer. After the embryogenic calli were irradiated, they were transferred to adventitious roots using an induction medium; next, mutated adventitious root (MAR) lines with a high frequency of adventitious root formations were selected. Two MAR lines (MAR 5-2 and MAR 5-9) from the calli treated with 50 Gy of gamma rays were cultured on an $NH_4NO_3$-free Murashige and Skoog medium with indole-3-butyric acid 3 mg/L. The expression of genes related to ginsenoside biosynthesis was analyzed using reverse transcription polymerase chain reaction with RNA prepared from native ginseng (NG), non-irradiated adventitious root (NAR) and 2 MAR lines. The expression of the squalene epoxidase and dammarenediol synthase genes was increased in the MAR 5-2 line, whereas the phytosterol synthase was increased in the MAR 5-9 line. The content and pattern of major ginsenosides (Rb1, Rb2, Rc, Rd, Re, Rf, and Rg1) were analyzed in the NG, NAR, and 2 MAR lines (MAR 5-2 and MAR 5-9) using TLC and HPLC. In the TLC analysis, the ginsenoside patterns in the NG, NAR, and 2 MAR lines were similar; in contrast, the MAR 5-9 line showed strong bands of primary ginsenosides. In the HPLC analysis, compared with the NG, one new type of ginsenoside was observed in the NAR and 2 MAR lines, and another new type of ginsenoside was observed in the 2 MAR lines irradiated with gamma rays. The ginsenoside content of the MAR 5-9 line was significantly greater in comparison to the NG.

Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method (듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용)

  • Kim, Myeong-Seong;Jeong, Jong-Seong;Kim, Myeong-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • OThe purpose of this article was to measure and compare the value of the metal artifact reduction (MAR) algorithm by Dual energy(kVp switching) CT (Computed Tomography) for non using MAR and we introduced new variable Dual energy CT applications through a clinical scan. The used equipment was GE Discovery 750HD with Dual-Energy system(kVp switching). CT scan was performed on the neck and abdomen area subject for patients. Studies were from Dec 20 2010 to Feb 10 2011 and included 25 subject patients with prosthesis. We were measured the HU (Hounsfield Unit) and noise value at metal artifact appear(focal loss of signal and white streak artifact area) according to the using MAR algorithm. Statistical analyses were performed using the paired sample t-test. In patient subject case, the statistical difference of showing HU was p=0.01 and p=0.04 respectively. At maximum black hole artifact area and white streak artifact area according to the using MAR algorithm. However noise was p=0.05 and p=0.04 respectively; and not the affected black hole and white streak artifact area. Dual Energy CT with the MAR algorithm technique is useful reduce metal artifacts and could improve the diagnostic value in the diagnostic image evaluation of metallic implants area.

Metal artifact production and reduction in CBCT with different numbers of basis images

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Groppo, Francisco Carlos;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.41-44
    • /
    • 2018
  • Purpose: To evaluate the effect of different numbers of basis images and the use of metal artifact reduction (MAR) on the production and reduction of artifacts in cone-beam computed tomography images. Materials and Methods: An acrylic resin phantom with a metal alloy sample was scanned, with 450 or 720 basis images and with or without MAR. Standard deviation values for the test areas (around the metal object) were obtained as a way of measuring artifact production. Two-way analysis of variance was used with a 5% significance level. Results: There was no significant difference in artifact production among the images obtained with different numbers of basis images without MAR (P=.985). MAR significantly reduced artifact production in the test areas only in the protocol using 720 basis images (P=.017). The protocol using 450 basis images with MAR showed no significant difference in artifact production when compared to the protocol using 720 basis images with MAR (P=.579). Conclusion: Protocols with a smaller number of basis images and with MAR activated are preferable for minimizing artifact production in tomographic images without exposing the patient to a greater radiation dose.

Quantitative and Qualitative Evaluation according to Radiation Dose Conditions when using MAR function in Implant examination from Cone Beam CT (ConeBeam CT로 임플란트 검사 시 MAR 기능 유무와 선량조건에 따른 정량적 및 정성적 평가)

  • Hyun-Jun, Ahn;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.905-917
    • /
    • 2022
  • This study was conducted to evaluate the use of the MAR function and the image quality of the image when examining with each radiation dose. A simple Periapical phantom was made to set up an implant, and images were obtained and analyzed according to the presence or absence of MAR function for each radiation dose using CBCT equipment. In this study, MEAN, SNR, and CNR values were obtained using the Image J program, and through statistical analysis, images were the most quantitative and suitable values when the Abutment of Implant was 100 kVp and 8 mA, and when the Center of Implant and Apex of Implant were 100 kVp and 9 mA. As a result, it was confirmed that if the radiation dose increased, the Pixel Value, SNR, and CNR values of the image rose up so that the quality of the image improved, and using the MAR function reduced artifacts.

Mar Behavior and Quantitative Evaluation of Urethane-Acrylate Coatings with a Different Gloss (다른 광택을 가진 우레탄 아크릴 코팅 소재의 긁힘 거동 및 정량적 평가)

  • Jung, Won-Young;Weon, Jong-Il
    • Polymer(Korea)
    • /
    • v.37 no.4
    • /
    • pp.455-461
    • /
    • 2013
  • Mar behavior and visibility were investigated by applying a constant load to various gloss-coated urethane-acrylate surfaces. Using a area-contact scratch tip which can apply a relatively low stress level to the coated surfaces, the mar damages were generated on the surfaces. When evaluating the mar-induced damage by means of delta-gloss (${\Delta}G$) and delta-luminance (${\Delta}L$) with existing test methodologies, an increase in constant load on the same gloss-coated surface leads to an increase in ${\Delta}G$ and ${\Delta}L$. However, these are not suitable for evaluating and comparing the surface damages of different gloss-coated samples because of a disagreement between the measured values and the mar visibility. It is shown that new mar test assessment proposed in this work not only can be used to quantitatively evaluate the mar damage, but also accounts for the correlation that the increases of the normalized gloss and luminance on coated surfaces correspond with an increase in the mar visibility.

Application of HACCP principles to MAR-based drinking water supply system (MAR기반 음용수 공급 시스템에의 HACCP 원리 적용)

  • Ji, Hyon Wook;Lee, Sang-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.533-543
    • /
    • 2016
  • Supplying clean and safe water to people is facing both quantitative and qualitative challenges. Due to climate change, access to freshwater becomes increasingly difficult, while pollution from various sources decreases the public trust in water quality. Managed aquifer recharge (MAR) which stores and uses surface water in aquifer is receiving attention as a new technology to secure freshwater. Recently, there is a global expansion in the attempt to combine general purification plants and hazard analysis and critical control point (HACCP) which manages all the process from raw material to consumer for food safety. This research is about an attempt to apply HACCP to the drinking water supply process using MAR to secure both quantity and quality of drinking water. The study site is a MAR plant being constructed in the downstream area of the Nakdong River Basin, South Korea. The incorporation of HACCP with MAR-based water supply system is expected to enhance the safety and reliability of drinking water.

The Effect of Process Oriented Guided Inquiry Learning Using Mobile Augmented Reality on Science Achievement, Science Learning Motivation, and Learning Flow in Chemical bond (화학 결합에서 모바일 증강현실을 이용한 과정기반 안내탐구학습이 과학 학업 성취도, 과학 학습 동기, 학습 몰입감에 미치는 영향)

  • Jeon, Young-Eun;Ji, Joon-Yong;Hong, Hun-Gi
    • Journal of The Korean Association For Science Education
    • /
    • v.42 no.3
    • /
    • pp.357-370
    • /
    • 2022
  • In this paper, we developed an augmented reality learning tool suitable for chemical bond learning and proposed a process-oriented guided inquiry learning using mobile augmented reality (POGIL-MAR) to find out how it affects science achievement, science learning motivation and learning flow. Participants were 139 10th-grade students from a coeducational high school in Gyeonggi-do, and they were randomly assigned to the control group (TL), the treatment group 1 (POGIL), and the treatment group 2 (POGIL-MAR). They learned the concept of the chemical bond from the Integrated Science subject for four class periods. Results of two-way ANCOVA revealed that the POGIL-MAR group scored significantly higher than the other groups in a science achievement test, science learning motivation test, and learning flow test, regardless of their prior science achievement. In addition, in the case of the low-level group, the POGIL-MAR group showed a statistically significant improvement in achievement compared to the TL and POGIL groups. The MANCOVA analysis for sub-factors of science learning motivation show that the POGIL-MAR group had significantly higher scores in intrinsic motivation, career motivation, self-determination, self-efficacy, and grade motivation. In particular, the interaction effect between the teaching and learning method and the level of prior achievement was significant in the intrinsic motivation. Meanwhile, the MANCOVA analysis for sub-factors of learning flow show that the POGIL-MAR group had significantly higher scores in clear goals, unambiguous feedback, action-awareness merging, sense of control, and autotelic experience. Based on the results, educational implications for effective teaching and learning strategy using mobile augmented reality are discussed.

A Study on Information System of MarNIS (MarNIS 정보체계에 대한 고찰)

  • Kim, Hye-Jin;Kim, Sun-Young;Lee, Moon-Jin;Hwang, Ho-Jin
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.121-126
    • /
    • 2007
  • 지난해 국제해사기구 (IMO)의 MSC 는 NAV 및 COMSAR 전문위원회에 E-Navigation 에 대한 전략 개발을 지시하였다. 효율적이고 안전한 선박 운항을 위한 E-navigation 서비스 구현을 위해서 해상 정보와 정보체계에 대한 이해가 선행되어야한다. 본 연구에서는 현재 범유럽적 차원에서 진행 중인 MarNIS 의 정보체계와 정보 에이전트에 대해서 살펴보았다. MarNIS 는 에이전트의 정보 창구로서의 Single Window와 각 시스템 말단에서 데이터 변환기로서의 MarNIS 노드에 의해 범유럽의 해상정보체계를 수립하고 있다. 정보 에이전트들이 계층적으로 구조화되고 통합된 해상 정보체계를 기반으로 각종 해상정보를 종합 분석하여 해상교통 지원 서비스와 해상안전 지원 서비스를 구현할 수 있다.

  • PDF

Analysis of the artifact reduction rate for the types of medical metals in CT with MAR algorithm (CT의 MAR알고리즘 적용 시 의료용 금속 물질별 인공물 감소율 분석)

  • Kim, Hyeon-ju;Yoon, Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.655-662
    • /
    • 2016
  • We investigated on the usefulness of MAR algorithm by making a comparison of the CT value between before and after applying the MAR algorithm in dual energy CT, using the various kinds of medical metals, causing the artifact to lead to the low image quality. As a result, the artifact was reduced in most cases (P<0.05); in particular, the artifact was highly reduced (P<0.05) using high density material, like alloy-stainless (reduced by 78.1%) and platinum, for example GDC coil (reduced by 76.1%). The effect of decreasing the Black hole artifact was outstanding in both the alloy-stainless and alloy-titanium (P<0.05). However, in case of GDC coil-a type platinum, white streak artifact was reduced effectively (P<0.05). Therefore, in case of patients who have medical metals inserted, we think that high-quality image information can be provided by decreasing the artifact caused by high density material through MAR algorithm in dual energy CT.