• Title/Summary/Keyword: mapping system

Search Result 2,333, Processing Time 0.029 seconds

Topographic mapping using digital map Ver.2.0 (수치지도 Ver.2.0을 이용한 종이지도제작기법 개발)

  • 황창섭;정성혁;함창학;이재기
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.281-286
    • /
    • 2003
  • Since National Geographic Information System was started, paper maps have been made with computer aided editing of digital map, instead of etching map-size negative film. Automated paper mapping system's necessity is growing more and more, because digital map has changed into Ver.2.0 which include attributes of feature. Therefore, in this study we try to analyze correlation of the digital map feature code and the 1/5,000 topographic map specifications which is necessary for paper mapping automatization using digital map Ver.2.0, and try to develop fundamental modules which will play a core role in automated paper mapping system.

  • PDF

Mapping Topic Maps using WordNet ontology (워드넷 온톨로지를 이용한 토픽맵 매핑)

  • Yoo, Woo-Jong;Kim, Jin-Woo;Kwon, Ju-Hum
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10a
    • /
    • pp.175-177
    • /
    • 2004
  • In this paper, we provide a mechanism to map topics between similar Topic Map ontologies, which enlarge the capacities of current Topic Maps. That is, there is no explicit way to map topics across multiple Topic Maps in current technology. Therefore, our approach provide semi-automatic or automatic mapping of topics between Topic Maps. In order to map the topics, we provide precise definitions of mapping properties and mapping rules.

  • PDF

Accuracy Analysis of Point Cloud Data Produced Via Mobile Mapping System LiDAR in Construction Site (건설현장 MMS 라이다 기반 점군 데이터의 정확도 분석)

  • Park, Jae-Woo;Yeom, Dong-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.397-406
    • /
    • 2022
  • Recently, research and development to revitalize smart construction are being actively carried out. Accordingly, 3D mapping technology that digitizes construction site is drawing attention. To create a 3D digital map for construction site a point cloud generation method based on LiDAR(Light detection and ranging) using MMS(Mobile mapping system) is mainly used. The purpose of this study is to analyze the accuracy of MMS LiDAR-based point cloud data. As a result, accuracy of MMS point cloud data was analyzed as dx = 0.048m, dy = 0.018m, dz = 0.045m on average. In future studies, accuracy comparison of point cloud data produced via UAV(Unmanned aerial vegicle) photogrammetry and MMS LiDAR should be studied.

Characteristic Evaluation of Pressure Mapping System for Patient Position Monitoring in Radiation Therapy

  • Kang, Seonghee;Choi, Chang Heon;Park, Jong Min;Chung, Jin-Beom;Eom, Keun-Yong;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.153-158
    • /
    • 2021
  • Purpose: This study evaluated the features of a pressure mapping system for patient motion monitoring in radiation therapy. Methods: The pressure mapping system includes an MS 9802 force sensing resistor (FSR) sensor with 2,304 force sensing nodes using 48 columns and 48 rows, controller, and control PC (personal computer). Radiation beam attenuation caused by pressure mapping sensor and signal perturbation by 6 and 10 mega voltage (MV) photon beam was evaluated. The maximum relative pressure value (mRPV), average relative pressure value (aRPV), the center of pressure (COP), and area of pressure distribution were obtained with/without radiation using the upper body of an anthropomorphic phantom for 30 minutes with 15 MV. Results: It was confirmed that the differences in attenuation induced by the FSR sensor for 6 and 10 MV photon beams were small. The differences in mRPV, aRPV, area of pressure distribution with/without radiation are about 0.6%, 1.2%, and 0.5%, respectively. The COP values with/without radiation were also similar. Conclusions: The characteristics of a pressure mapping system during radiation treatment were evaluated on the basis of attenuation and signal perturbation using radiation. The pressure distribution measured using the FSR sensor with little attenuation and signal perturbation by the MV photon beam would be helpful for patient motion monitoring.

An Adaptive Photon Mapping in the Use of Automatic Differentiation

  • Namae, Takuya;Makino, Mitsunori
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.991-994
    • /
    • 2002
  • Photon mapping is an efficient global illumination technique for realistic image synthesis that has been developed in computer graphics. In this paper, an adaptive photon mapping in the use of automatic differentiation is proposed. Since the automatic differentiation is used when photons emit from the light sources through the scene, we can check the variation of surrounding shape. Therefore, we can decrease the number of photons and generate an image in relatively low computational cost.

  • PDF

System-level Design Space Exploration and Resource Mapping Strategies for a Reconfigurable Hybrid System

  • Ahn, Seong-Yong;Lee, Jeong-A
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.924-927
    • /
    • 2002
  • In this paper we proposed the design space exploration environment of re-configurable hybrid systems and evaluate the performance by changing design parameters. With this, we analyzed the effect of various scheduling methods which determine how we allocate hardware/software resources to application program. A simple static (fixed) mapping strategy produces almost the same performance compared with a sophisticated dynamic mapping strategy especially when a CPU is already busy with its pre-assigned own tasks.

  • PDF

Exchange of the Product Structure Data of STEP between CAD and PDM Systems (CAD와 PDM 시스템 간에 STEP 제품 구조 정보의 교환)

  • 오유천;한순흥
    • Korean Journal of Computational Design and Engineering
    • /
    • v.5 no.3
    • /
    • pp.215-223
    • /
    • 2000
  • The product data exchange between heterogeneous CAB and PDM systems is a crucial issue for the integration of product development systems. STEP offers an efficient mechanism of product data exchange between heterogeneous systems. This paper introduces a UML-based mapping methodology for the product data models. The suggested mapping method has been applied to exchange the product structure data between CAD and PDM systems. Based on the STEP methods, we developed an interface module between a CAD system and a PDM system.

  • PDF

GENERAL SYSTEM OF MULTI-SEXTIC MAPPINGS AND STABILITY RESULTS

  • Abasalt Bodaghi
    • Communications of the Korean Mathematical Society
    • /
    • v.38 no.2
    • /
    • pp.509-524
    • /
    • 2023
  • In this study, we characterize the structure of the multivariable mappings which are sextic in each component. Indeed, we unify the general system of multi-sextic functional equations defining a multi-sextic mapping to a single equation. We also establish the Hyers-Ulam and Găvruţa stability of multi-sextic mappings by a fixed point theorem in non-Archimedean normed spaces. Moreover, we generalize some known stability results in the setting of quasi-𝛽-normed spaces. Using a characterization result, we indicate an example for the case that a multi-sextic mapping is non-stable.