• Title/Summary/Keyword: manufactured device

Search Result 627, Processing Time 0.04 seconds

Design and Control of Haptic Cue Device for Accelerator Pedal Using MR Brake (MR 브레이크를 이용한 햅틱 큐 가속페달 장치 설계 및 제어)

  • Noh, Kyung-Wook;Han, Young-Min;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.627-632
    • /
    • 2009
  • This paper proposes a new haptic cue vehicle accelerator pedal device using magnetorheological (MR) brake. As a first step, an MR fluid-based haptic cue device is devised to be capable of rotary motion of accelerator pedal. Under consideration of spatial limitation, design parameters are optimally determined to maximize control torque using finite element method. The proposed haptic cue device is then manufactured and integrated with accelerator pedal. Its field-dependant torque is experimentally evaluated. Vehicle system emulating gear shifting and engine speed is constructed in virtual environment and communicated with the haptic cue device. Haptic cue algorithm using the feed-forward control algorithm is formulated to achieve optimal gear shifting in driving. Control performances are experimentally evaluated via feed-forward control strategy and presented in time domain.

  • PDF

A study of automatic train operation by ATC system and fault tracing (ATC장치에 의한 자동운전 및 고장 추적에 관한 연구)

  • 김경식;강덕원;강리택;이종성
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.503-508
    • /
    • 2002
  • According to passengers gain and headway's contraction, railway vehicle is required quick and correct running. The importance of ATC device was increased gradually, and also is acting important role in safe train running and efficient use in this reason. Now, railway vehicle that is manufactured or is remodeled are designed to most automatic driving system, and ATC device design direction than other device of railway vehicle influences to whole system in this reason. Also, according as system becomes complicated gradually, importance of fault tracing function fur ATC device is emphasized gradually, and in this reason research about efficient fault tracing method is to act important role heightening reliability of ATC device. In this document, that analyzing about result through examination of automatic train operation system of localization model ATC device(SG-100) and application example, and do so that investigate about efficient fault Bracing.

  • PDF

An analysis on satisfaction level of clinicians on implant surgical guidance system based on computed tomography (컴퓨터 단층 촬영을 기반으로 한 임플란트 가이드 시스템에 대한 임상가의 만족도 분석)

  • Hong, Min-ho;Jin, Ming-Xu;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.178-185
    • /
    • 2015
  • Purpose: The purpose of this study was to conduct a comparative assessment on the satisfaction level for the two interfaces of surgical guide system (SimPlant and R2GATE), the design and convenience of manufactured surgical guides and the importance of using the surgical guides thereof by means of survey. Materials and Methods: Hereupon, they simulated the implant surgical process by mounting the two manufactured systems of surgical guide on a dental mold, respectively. The study subjects were instructed to complete the questionnaire as to the satisfaction level upon completion of the simulated surgery. This study summarized the data of each question after collecting the completed questionnaires. Then, this study analyzed the summarized data by utilizing statistical program SPSS 20.0 (IBM). Results: R2GATE had a higher value of the satisfaction level on the design and convenience of manufactures surgical guides. R2GATE group ($7.33{\pm}1.26$) was found to have a higher value in terms of the overall satisfaction level compared to SimPlant group ($6.67{\pm}1.26$) (${\alpha}$ = 0.05). Conclusion: The user satisfaction level on the surgical guide manufactured for R2GATE system was to such an extent as it can be widely used in clinical environment. Moreover, the surgical guide manufactured as R2GATE system can guide both the length and direction of a drill simultaneously. As a result, it is highly recommended for those beginners who do not have a lot of experience in implant placement.

A Study on the Ultra-Small Pendulum Generator Applicable to Wearable IT Device (웨어러블 IT 기기에 적용 가능한 초소형 진자 발전기에 관한 연구)

  • Jee, In-Ho;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.139-143
    • /
    • 2022
  • In this study, Among the electromagnetic induction power generation (EMG) techniques, the design specifications of the RFPM were set, and a suitable test prototype was manufactured through finite element analysis (FEM, 2D) required for characteristic calculation. In addition, a dedicated testing device (Dynamo-Tester) was designed and manufactured to measure and analyze the test prototype. The test product was measured with a test device and the result is analyzed to suggest a method that can be applied by generating as much output power as possible to charge the battery of the wearable IT device using actual kinetic energy of the human body. As a result of the test, the output power was 1.679W and the efficiency was 79.31% under the conditions of rotation speed of 780.9rpm, torque of 0.264kgf/cm, and load current of 73.6~73.9mA. Therefore, it was analyzed that it was possible to charge the wearable device with the output of the ultra-small RFPM pendulum generator.

Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device (이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정)

  • Hong, Sun-Suk;Kim, Deuk-Yong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

Analysis for designing a device to transport radioactive contaminated materials in hotcell (핫셀의 방사성오염물질 운반장치 설계를 위한 분석)

  • 홍동희;진재현;정재후;김영환;윤지섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1021-1024
    • /
    • 2004
  • During demonstrations of a process conditioning spent nuclear fuels, it may be necessary to transport modularized parts of process equipment out of a hot cell because of modules' failure or completion of demonstrations. It may be not easy to transport modules because modules will be contaminated. For this purpose, we have developed a prototype of a device transporting radioactive contaminated materials. We have analyzed conditions of a hot cell and requirements of the device, designed and manufactured a scaled-down prototype of the device, and done some performance tests such as running on the rail, running on the flat floor, and carrying capability of a sliding upper part. From the tests, it has been shown that running on the rail and floor was smooth but the sliding part was deflected if the sliding distance was long. These result will be reflected to a design of the improved transporting device which will be used during demonstrations.

  • PDF

A Method to Prevent Transfer Device of Image Stabilizer from Blunting by Artificial Vibration (가진입력에 의한 손떨림 보정용 이송장치의 둔화현상 방지대책)

  • Yeom, Dong-Hae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.11
    • /
    • pp.1076-1079
    • /
    • 2009
  • This article deals with an optical image stabilizer which moves an image sensor in the direction of cancelling the vibration caused by hand shaking to prevent a photographed image from blurring. The ball-guide way method adopted as a transfer device of the image sensor is easy to be manufactured because of its simple structure and is suitable to minimize the friction between mechanisms, but has weakness of a chance of physical defect such as groove and rising. In case that the movement of the transfer device equipped with the image sensor is blunted because a ball is stuck in defects of guide way, the performance of the image stabilizer falls down drastically. We propose a method to prevent the transfer device from blunting by applying artificial vibration. At this time, the artificial vibration should be designed under consideration of dynamic characteristics and specifications of the system to be discriminated from the vibration caused by hand shaking.

Characteristics of Erbium silicided n-type Schottky barrier tunnel transistors (Erbium 실리사이드를 이용하여 제작한 n-형 쇼트키장벽 관통트랜지스터의 전기적 특성)

  • Moongyu Jang;Kicheon Kang;Sunglyul Maeng;Wonju Cho;Lee, Seongjae;Park, Kyoungwan
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.779-782
    • /
    • 2003
  • The theoretical and experimental current-voltage characteristics of Erbium silicided n-type Schottky barrier tunneling transistors (SBTTs) are discussed. The theoretical drain current to drain voltage characteristics show good correspondence and the extracted Schottky barrier height is 0.24 eV. The experimentally manufactured n-type SBTTs with 60 nm gate lengths show typical transistor behaviors in drain current to drain voltage characteristics. The drain current on/off ratio is about 10$^{5}$ at low drain voltage regime in drain current to gate voltage characteristics.

  • PDF

Deployment Behaviors of CFRP Reflector under Zero-gravity Environment

  • Chae, Seungho;Oh, Young-Eun;Lee, Soo-Yong;Roh, Jin-Ho
    • International Journal of Aerospace System Engineering
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • A deployment mechanism is designed to stow into a small volume efficiently. The panels are fabricated by carbon fiber reinforced plastics (CFRPs). The parameters for the deployment are determined by considering the number of panels, the folding/twisting angles, and the driving force for a deployment device. In addition, a surface accuracy of the manufactured reflector is measured through a photogrammetry methodology. The deployment behavior of CFRP reflector is observed by using the zero-gravity device which compensates the gravity effect during the deployment. The zero-gravity device is constructed wire, motor, controller and loadcell. During the deployment of the reflector panel, the wire and motor compensate for its weight by the feedback process of the controller. Tests result show that a zero-gravity device compensates for the weight of the panel during the deployment of the CFRP reflector.

Electrical Properties by Organic Thin Films According to Manufacture Condition (제작조건에 따른 유기박막의 전기특성)

  • Song, Jin-Won;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.467-469
    • /
    • 2000
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 20[mN/m]. LB layers of Arac. acid deposited by LB method were deposited onto Y-type silicon wafer as x, y, z-type film. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/arachidic acid/Al, the number of accumulated layers Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V].

  • PDF