• Title/Summary/Keyword: manual method

Search Result 1,818, Processing Time 0.033 seconds

Comparison of Manual Chest Compression and Chest Compression Using AutoPulseTM Device in Pre-Hospital Simulation Cardiac arrest

  • Ko, Jang-Sik;Kim, Yong-Seok;Lim, Se-Young;Kim, Soo-Tae;Kim, Keun-Hee;Hwang, Sung-Hoon;Cho, Byung-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.10
    • /
    • pp.151-156
    • /
    • 2018
  • The purpose of this study was to find more effective method through comparison of manual chest compression and chest compression using $AutoPulse^{TM}$ device in pre-hospital simulation cardiac arrest. In order to achieve the purpose of the study, ambulance workers did two different style CPR in pre-hospital simulation cardiac arrest. Data analyzed by T test and ANOVA. Findings of this study are as follows. Firstly, manual chest compression is more effective than chest compression using $AutoPulse^{TM}$ device on scene. Secondly, chest compression using $AutoPulse^{TM}$ device is more effective manual chest compression in ambulance and in elevator. In conclusion, these findings provide strong evidence for the importance of hands off time and stable CPR before hospital arrival in explaining patient's prognosis. Therefore, strategies to conduct precise hands off time and stable CPR are needed to improve patient's prognosis.

The Development of Automatic Design Software for DC Motor Servo Controller (DC 모터 서보 제어기의 자동 설계 S/W 개발)

  • Huh, Kyung-Moo;Lee, Eun-O;Cho, Young-June
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.10
    • /
    • pp.888-893
    • /
    • 2000
  • This paper deals with the development of an automatic design software for DC servo motor control, which provides good performance with rapid response and velocity control accuracy. In the proposed method, the design is automatically executed using Matlab, and iterative learning control algorithms are used in the design process. We applied this method to 50W, 100W, 200W, 300W, 500W, 750W, 1.8kW and 4.5kW DC servo motors which are widely used in the industry. We compare the results of the manual tuning design method with that of the automatic design method presented in this paper. From the experimental results, we can find that the performance of the proposed method is better than that of the manual tuning design method.

  • PDF

Two Cases on Tortipelvis caused by Lumbar Disc Herniation - Using Mckenzie Method Treatment (요추 추간판 탈출증에 의한 골반경사 치험 2례 - Mckenzie 수기요법을 이용)

  • Hwang, Hyung-Joo;Heo, Kwang-Ho;Keum, Dong-Ho
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.2 no.1
    • /
    • pp.85-97
    • /
    • 2007
  • Objectives : We evaluated the effect of Mckenzie method treatment by participating two patients suffering from Tortipelvis by lumbar disc herniation. Methods : Two patients were diagnosed as Tortipelvis by lumbar disc herniation through CT scan and X-ray examination. We used Mckenzie method and measured VAS(Visual analogue scale). Results and Conclusions : After using Mckenzie method treatment, We found out a recovery from both patients suffering from Tortipelvis by lumbar disc herniation. The result, through our study, suggests that Mckenzie method treatment was effective to cure the Tortipelvis by lumbar disc herniation. It also was effective to reduce the low back pain and to stabilize the lumbar disc herniation.

  • PDF

Development and Evaluation of Health Care Providers' Counseling Manual in Mobile Application for Lifelong Health Care among Patients with Chronic Hepatitis B (만성 B형간염환자의 평생건강관리를 위한 모바일 앱 건강관리자용 상담매뉴얼 개발 및 평가)

  • Yang, Jinhyang;Lee, Haeok;Yoo, Kyung Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.20 no.1
    • /
    • pp.108-117
    • /
    • 2014
  • Purpose: The purpose of this study was to develop and validate health care providers' counseling manual in mobile application for lifelong health care among patients with chronic hepatitis B. Methods: The mobile application was developed using a prototyping approach and system developing life cycle method, evaluated by users for their satisfaction with the counseling manual and experts for the quality of the manual. To evaluate application of the counseling manual, knowledge and counselor self-efficacy of the subjects were measured and compared before and after application of the counseling manual. Results: There were statistically significant increases in knowledge and counselor self-efficacy in the user group. A mobile application with high accessibility and applicability including information and counseling factors can promote counseling competence of the nurse as health care provider caring chronic hepatitis B patients. Conclusion: The results of this study indicate that the counseling manual in mobile application is effective in increasing knowledge and counselor self-efficacy among nurses to promote lifelong health care among patients with chronic hepatitis B. Therefore, it can be usefully utilized in the field of nursing for patients with chronic hepatitis B as a nursing intervention.

The Effects of Therapeutic Approach of Patellofemoral Pain Syndrome with Asymmetrical Hip Rotation : Case Study (비대칭성 고관절 회전각을 지닌 슬개대퇴통증증후군 환자의 치료적 접근 - 사례연구)

  • Jang, Hyun-Jeong;Kim, Suhn-Yeop;Kim, Ho-Bong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.17 no.2
    • /
    • pp.41-48
    • /
    • 2011
  • Background: Patellofemoral pain syndrome is very common knee problem and altered hip rotation may play a role in patellofemoral pain. The purpose of this case study is to describe the manual therapy of and the therapeutic exercise for a patient with asymmetrical hip rotation and patellofemoral pain. Method: The patient was a 29 years old woman with an 3 month history of anterior right knee pain, without known trauma or injury. Prior to intervention, her score on the VAS was Max 6 to Min 4. Left hip internal rotation was less than right hip internal rotation, and manual muscle testing showed weakness of the left hip internal rotator and abductor muscles. The intervention consisted of manual therapy and therapeutic exercise for three times a weeks, two weeks for increasing right hip medial rotation, improving left hip muscle strength, and eliminating anterior right knee pain. Result: After intervention for 2weeks, passive left and right hip medial rotations were symmetrical, and her right hip internal rotator and abductor muscle grades were Good plus. Her VAS score was Max 2 to Min 0. Conclusion: Manual therapy and therapeutic exercise is effective in improving for patient had patellofemoral pain with pattern of asymmetrical hip rotation.

  • PDF

The Changes of Defibrillation Time Depending on the Manual External Defibrillator Device (제세동 시행도구에 따른 제세동 지연시간의 변화)

  • Park, Si-Eun;Shin, Dong-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.1
    • /
    • pp.81-90
    • /
    • 2012
  • Objectives: This study is to research delay time comparison for later defibrillation after hands off according to the changes in defibrillation electrodes. Study purpose: In defibrillation treatment that is the only way for cardiac arrest by arrhythmia, it is to find defibrillator device which can minimize late defibrillation delay time after important affect of hands off. Study object and method: After hands off according to the defibrillator device, we collected total 40 people for emergency medicine doctor, internal medicine doctor, general surgeon, nurse, emergency medical technician who are working at 2 CN, CS University hospitals in Gwangju Jeollanamdo district to find out hand off shock interval(HOSI). We then researched their general properties like occupation sector, experiences in clinic, gender, completion of AHA ACLS-P training and more. Then 40 participants continued ventricular fibrillation cardiac arrest simulation training (using human-model mannequin) designed by researcher and performed their roles as defibrillation operator. Each of participant used manual paddle and performed 4 times of defibrillation (150J) during 8 minutes of CPR and in 8day, the defibrillator devices were replaced from manual paddle to self-adhesive electrodes pads and 4 times of defibrillation (150J) under same simulation condition as manual paddle were performed. Study result: In comparison for delay time of later defibrillation after hands off of manual paddle and self adhesive electrodes pad, the self adhesive electrodes pad ($7.0{\pm}0.5sec$) seemed to reduce delay time of later defibrillation significantly (p<0.05) compared to manual paddle ($10.0{\pm}0.9sec$). The self adhesive electrodes pad, according to the general properties of participants, had no particular change in delay time after later defibrillation for the statistics (p>0.05) but the manual paddle had statistically significant differences for the occupation sector, experiences in clinic and gender (p<0.05). Conclusion: In defibrillation, the self adhesive electrodes pad($7.0{\pm}0.5sec$) showed short HOSI compared to manual paddle ($10.0{\pm}0.9sec$) significantly (p<0.05) and it applied identically for both existence and non-existence of ACLS-P training completion, experiences in clinic, gender and occupation sector. The manual paddle had also significant difference in experiences in clinic and occupation sector (p<0.05). which means the effect on HOSI according to the job mastery. Therefore, if the clinic experience is short or in case for the occupations without frequent defibrillation treatment has a danger of lowering success rate for the defibrillation using manual paddle. Therefore, it is true that using self adhesive electrodes pad for defibrillation electrodes when performing manual defibrillation in pre-hospital as well as in-hospital steps can generally minimize delay time of later defibrillation after hands off.

Railway Car Window wiper System Application Investigation (철도차량 윈도와이퍼 우적 System 적용 검토 고찰)

  • Ko, Young-Ho;Lee, Gi-Su;Cha, Gwan-Bong;Lee, Shuk-Hyung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.755-760
    • /
    • 2007
  • The research will be essential that the method for strengthening safety are safe installations in a hardware portion, a safe running ceremony of the vehicle employee (an engine driver) and the estimate of the situation which is accurate. In railway car the window wiper which is auxiliary equipment for safe operation is changed the existing manual control method with automatic correspondence precipitation used raindrops censor which can assure the vision of driving. It can be easy to safe driving as might have expected the object. We carried out studies technical review investigation which can accomplish the best suited wiping speed in maintaining an introduction existing system in the manual control system applied the existing train and corresponding to precipitation. The observation fact in the studies can be possible to ensure safety operation. That is, Manual operation method (of the driver) to add the automatic speed adjust function can operate improved window wiper drive system when it rains and, as was expected, it is able to ensure the range of a good railroad driver's vision and to concentrate in working at rainfall.

  • PDF

Analysis on the result of I/I calculation by the exiting method and the standardized maual method (하수관거 I/I(침입수/유입수) 분석방법에 따른 산정 결과 비교 -기존 보정방법과 환경부 표준 매뉴얼에 의한 방법-)

  • An, Byung-Mo;Song, Ho-Myun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.213-221
    • /
    • 2011
  • The purpose of sewer system is to separate rain water from sewage water. Through this, it is possible to prevent the flood and preserve public water territory. For the past few years, many problems of the sewer system have been solved by the execution of sewer rehabilitation project. However, they still exist in sewer system caused by I/I, which are divided into infiltration and inflow. Infiltration means the rain water and underground water that infiltrate through breakage point on pipes, inflow means the water that flows in through misconnection on pipes. This study shows how the I/I calculation has changed according to the new standardized manual and identifies the I/I difference between the new calculation and the existing one. Through the analysis on the two calculation methods we examined the appropriacy of the new method by comparing it to the old one. The result points out that the new standardized manual is more appropriate than the old in aspect of objectivity and reproducibility(establish standardization), rationality(alteration of inflow unit).

Total Intracranial Volume Measurement for Children by Using an Automatized Program (자동화 프로그램을 이용한 아동의 전체두개강내용적 평가)

  • Lee, Jeonghwan;Kim, Ji-Eun;Im, Sungjin;Ju, Gawon;Kim, Siekyeong;Son, Jung-Woo;Shin, Chul-Jin;Lee, Sang-Ick;Ghim, Hei-Rhee
    • Korean Journal of Biological Psychiatry
    • /
    • v.21 no.3
    • /
    • pp.81-86
    • /
    • 2014
  • Objectives Total intracranial volume (TIV) is a major nuisance of neuroimaging research for interindividual differences of brain structure and function. Authors intended to prove the reliability of the atlas scaling factor (ASF) method for TIV estimation in FreeSurfer by comparing it with the results of manual tracing as reference method. Methods The TIVs of 26 normal children and 26 children with attention-deficit hyperactivity disorder (ADHD) were obtained by using FreeSurfer reconstruction and manual tracing with T1-weighted images. Manual tracing performed in every 10th slice of MRI dataset from midline of sagittal plane by one researcher who was blinded from clinical data. Another reseacher performed manual tracing independently for randomly selected 20 dataset to verify interrater reliability. Results The interrater reliability was excellent (intraclass coefficient = 0.91, p < 7.1e-07). There were no significant differences of age and gender distribution between normal and ADHD groups. No significant differences were found between TIVs from ASF method and manual tracing. Strong correlation between TIVs from 2 different methods were shown (r = 0.90, p < 2.2e-16). Conclusions The ASF method for TIV estimation by using FreeSurfer showed good agreement with the reference method. We can use the TIV from ASF method for correction in analysis of structural and functional neuroimaging studies with not only elderly subjects but also children, even with ADHD.

Structural analysis of trabecular bone using Automatic Segmentation in micro-CT images (마이크로 CT 영상에서 자동 분할을 이용한 해면뼈의 형태학적 분석)

  • Kang, Sun-Kyung;Jung, Sung-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.3
    • /
    • pp.342-352
    • /
    • 2014
  • This paper proposes an automatic segmentation method of cortical bone and trabecular bone and describes an implementation of structural analysis method of trabecular bone in micro-CT images. The proposed segmentation method extract bone region with binarization using a threshold value. Next, it finds adjacent contour lines from outer boundary line into inward direction and sets candidate regions of cortical bone. Next it remove cortical bone region by finding the candidate cortical region of which the average pixel value is maximum. We implemented the method which computes four structural indicators BV/TV, Tb.Th, Tb.Sp, Tb.N by using VTK(Visualization ToolKit) and sphere fitting algorithm. We applied the implemented method to twenty proximal femur of mouses and compared with the manual segmentation method. Experimental result shows that the average error rates between the proposed segmentation method and the manual segmentation method are less than 3% for the four structural indicatiors. This result means that the proposed method can be used instead of the combersome and time consuming manual segmentation method.