• Title/Summary/Keyword: main controller

Search Result 954, Processing Time 0.023 seconds

Implementation of TFDR system with PXI type instruments for detection and estimation of the fault on the coaxial cable (동축 케이블의 결함 측정에 있어서 PXI 타입의 계측기를 이용한 개선된 TFDR 시스템의 구현)

  • Choe, Deok-Seon;Park, Jin-Bae;Yun, Tae-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.91-94
    • /
    • 2003
  • In this paper, we achieve implementation of a Time-Frequency Domain Reflectometry(TFDR) system through comparatively low performance(100MS/s) PCI extensions for Instrumentation(PXI). The TFDR is the general methodology of Time Domain Reflectometry(TDR) and Frequency Domain Reflectometry(FDR). This methodology is robust in Gaussian noises, because the fixed frequency bandwidth is used. Moreover, the methodology can get more information of the fault by using the normalized time-frequency cross correlation function. The Arbitrary Waveform Generator(AWG) module generates the input signal, and the digital oscilloscope module acquires the input and reflected signals, while PXI controller module performs the control of the total PXI modules and execution of the main algorithm. The maximum range of measurement and the blind spot are calculated according ta variations of time duration and frequency bandwidth. On the basis of above calculations, the algorithm and the design of input signals used in the TFDR system are verified by real experiments. The correlation function is added to the TDR methodology for reduction of the blind spot in the TFDR system.

  • PDF

Design and analysis of RF-DC power conversion circuit (무선 전력변환장치의 전력변환 회로에 대한 설계 및 분석)

  • Kim, Yong-Sang;Im, Sang-Uk;Lee, Yong-Je;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.35-42
    • /
    • 2003
  • We have studied DC energy conversion of RF card by wireless communication. In order to attain an objective, it used the system which is a Rectenna. The main purpose of energy conversion system is the operation of the circuits at RF-ID system. The proposed RF-ID system is a lot classified with the reader and tag. Reader is a kind of the base station role supporting RF energy. And priority tag convert RF energy from the reader it was delivered with a wireless to DC energy. The energy which is converted like Tag. It transmits to the reader characteristic ID of each card. The tag is mainly divided into rectifier, power module, memory and controller. The FRAM maintains the data like a ROM in no-power situation. And the advantage is a low power element compared with other EEPROM. There are two considerations, when RF energy is converted into DC source by wireless. One is energy amount supported from the reader, the other is high power efficiency. This paper presents a study of simulation and experiments on the RF-DC conversion circuit in tag by the power efficiency concentrated.

  • PDF

Study on the Dynamic Synchronizing Control of An Islanded Microgrid (독립운전 마이크로그리드의 능동형 동기 투입 제어에 관한 연구)

  • Cho, Chang-Hee;Jeon, Jin-Hong;Kim, Jong-Yul;Kwon, Soon-Man;Kim, Sung-Shin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1112-1121
    • /
    • 2011
  • A microgrid is an aggregation of multiple distributed generators (DGs) such as renewable energy sources, conventional generators, and energy storage systems that provide both electric power and thermal energy. Generally, a microgrid operates in parallel with the main grid. However, there are cases in which a microgrid operates in islanded mode, or in a disconnected state. Islanded microgrid can change its operational mode to grid-connected operation by reconnection to the grid, which is referred to as synchronization. Generally, a single machine simply synchronizes with the grid using a synchronizer. However, the synchronization of microgrid that operate with multiple DGs and loads cannot be controlled by a traditional synchronizer, but needs to control multiple generators and energy storage systems in a coordinated way. This is not a simple job, considering that a microgrid consists of various power electronics-based DGs as well as alternator-based generators that produce power together. This paper introduces the results of research examining an active synchronizing control system that consists of the network-based coordinated control of multiple DGs. Consequently, it provides the microgrid with a deterministic and reliable reconnection to the grid. The proposed method is verified by using the test cases with the experimental setup of a microgrid pilot plant.

Position Control for Interior Permanent Magnet Synchronous Motors using an Adaptive Integral Binary Observer

  • Kang, Hyoung-Seok;Kim, Cheon-Kyu;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.240-248
    • /
    • 2009
  • An approach to control the position for an interior permanent magnet synchronous motor (IPMSM) based on an adaptive integral binary observer is described. The binary controller with a binary observer is composed of a main loop regulator and an auxiliary loop regulator. One of its key features is that it alleviates chatter in the constant boundary layer. However, steady state estimation accuracy and robustness are dependent upon the thickness of the constant boundary layer. In order to improve the steady state performance of the binary observer and eliminate the chattering problem of the constant boundary layer, a new binary observer is formed by adding extra integral dynamics to the existing switching hyperplane equation. Also, the proposed adaptive integral binary observer applies an adaptive scheme because the parameters of the dynamic equations such as the machine inertia and the viscosity friction coefficient are not well known. Furthermore, these values can typically be easily changed during normal operation. However, the proposed observer can overcome the problems caused by using the dynamic equations, and the rotor position estimation is constructed by integrating the rotor speed estimated with a Lyapunov function. Experimental results obtained using the proposed algorithm are presented to demonstrate the effectiveness of the approach.

A Field State Investigation on Standalone PV streetlight for Development of Real-time Analysis Technology (독립형 태양광 가로등의 실시간 분석기술 개발을 위한 실태조사)

  • Kim, Doo Hyun;Kim, Sung Chul;Hwang, Dong Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.5
    • /
    • pp.10-14
    • /
    • 2013
  • This paper is aimed to investigate the actual conditions of standalone PV(Photovoltaics) streetlight in public place and analyze cause of failure and derive the method of decrease for standalone PV streetlight. The cost of installing standalone PV streetlight in a public for the safety and convenience of life is expensive(300 million won per unit). Management of standalone PV streetlight is important because it is operating system itself, after installation, but concern degree of management is very low and development of technology has not been done. Accordingly, standalone PV streetlight in public place is not operate in night, this phenomenon is lasted for several days to months. Therefore this study, for standalone PV streetlight constantly to keep the normal operation, investigation conducted to check status of standalone PV streetlight(50 units), the voltage of the main parts and analyze the cause of the failure. In addition, the improvement of standalone PV streetlight is suggested by using FTA(fault tree analysis).

Dual Current Control Scheme of a Grid-connected Inverter for Power Quality Improvement in Distributed Generation Systems (분산 전원 시스템의 전력품질 향상을 위한 계통연계 인버터의 이중 전류제어 기법)

  • Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.33-41
    • /
    • 2015
  • To improve the power quality of distributed generation (DG) systems even in the presence of distorted grid condition, dual current control scheme of a grid-connected inverter is proposed. The proposed current control scheme is achieved by decomposing the inverter state equations into the fundamental and harmonic components. The derived models are employed to design dual current controllers. The conventional PI decoupling current controller is used in the fundamental model to control the main power flow in DG systems. At the same time, the predictive control is applied in the harmonic model to suppress undesired harmonic currents to zero quickly. To decompose the voltage inputs and state variables into the fundamental and harmonic components, the fourth order band pass filter (BPF) is designed in the discrete-time domain for a digital implementation. For experimental verification, 2kVA prototype of a grid-connected inverter has been constructed using digital signal processor (DSP) TMS320F28335. The effectiveness of the proposed strategy is demonstrated through comparative simulation and experimental results.

Write Request Handling for Static Wear Leveling in Flash Memory (SSD) Controller

  • Choo, Chang;Gajipara, Pooja;Moon, Il-Young
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.3
    • /
    • pp.181-185
    • /
    • 2014
  • The lifetime of a solid-state drive (SSD) is limited because of the number of program and erase cycles allowed on its NAND flash blocks. Data cannot be overwritten in an SSD, leading to an out-of-place update every time the data are modified. This result in two copies of the data: the original copy and a modified copy. This phenomenon is known as write amplification and adversely affects the endurance of the memory. In this study, we address the issue of reducing wear leveling through efficient handling of write requests. This results in even wearing of all the blocks, thereby increasing the endurance period. The focus of our work is to logically divert the write requests, which are concentrated to limited blocks, to the less-worn blocks and then measure the maximum number of write requests that the memory can handle. A memory without the proposed algorithm wears out prematurely as compared to that with the algorithm. The main feature of the proposed algorithm is to delay out-of-place updates till the threshold is reached, which results in a low overhead. Further, the algorithm increases endurance by a factor of the threshold level multiplied by the number of blocks in the memory.

A Hysteresis Current Controller with Improved Voltage Waveform using N.P.C Structure (N.P.C 구조에 의한 히스테리시스 전류제어기의 전압파형 개선)

  • 김윤호;이병송
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.51-57
    • /
    • 1997
  • A new current controlled PWM technique with N.P.C structure is proposed in this paper. A current controlled PWM technique with neutral-point-clamped pulsewidth modulation inverter composed of main switching devices which operates as switches for PWM and auxiliary switching devices to clamp the output terminal potential to the neutral point potential is described. This inverter output contains less harmonic content as compared with that of a conventional current controlled PWM type. In addition, the proposed current controlled PWM technique has lower switching frequency than that of conventional current controlled PWM technique at the same current limit. Two inverters are compared analytically. The improved voltage waveform of current controlled PWM with N.P.C structure is analyzed and the performance is investigated by the computer simulation.

  • PDF

Induction Motor Vector Control for Drum Washing Machine (드럼 세탁기용 유도전동기의 효율운전에 관한 연구)

  • Jeong, Jeong-Gil;Lee, Won-Chul;Bae, Woo-Ri;Won, Chung-Yuen;Jang, Bong-An;Yang, Ha-Yeong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.473-478
    • /
    • 2005
  • In home appliances, electric energy is optimally controlled by using power electronics technology, creating a comfortable environment in terms of energy saving, low sound generation, and reduced time consumption. Usually simplicity and robustness make the three phase induction motor attractive for use in domestic appliance, including washing machines. Two main fpes of domestic washing machine have evolved. We focus on the front loading machine favored in Europe, which has a horizontal drum axis. With the advent of electronic control, universal motor, with a phase controller operating directly from the ac source, has become popular in washing machine. The efficiency improvement in home appliances is very important for customers. Induction motor efficiency can be improved by means of loss reduction, which can be realized by motor selection and design, improvement of the waveforms supplied by power inverter, utilizing a suitable control method. So this paper describes the architecture and feature of washing machine fed induction motor drive under minimizing losses vector control.

  • PDF

New Control Scheme for the Wind-Driven Doubly Fed Induction Generator under Normal and Abnormal Grid Voltage Conditions

  • Ebrahim, Osama S.;Jain, Praveen K.;Nishith, Goel
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.10-22
    • /
    • 2008
  • The wind-driven doubly fed induction generator (DFIG) is currently under pressure to be more grid-compatible. The main concern is the fault ride-through (FRT) requirement to keep the generator connected to the grid during faults. In response to this, the paper introduces a novel model and new control scheme for the DFIG. The model provides a means of direct stator power control and considers the stator transients. On the basis of the derived model, a robust linear quadratic (LQ) controller is synthesized. The control law has proportional and integral actions and takes account of one sample delay in the input owing to the microprocessor's execution time. Further, the influence of the grid voltage imperfection is mitigated using frequency shaped cost functional method. Compensation of the rotor current pulsations is proposed to improve the FRT capability as well as the generator performance under grid voltage unbalance. As a consequence, the control system can achieve i) fast direct power control without instability risk, ii) alleviation of the problems associated with the DFIG operation under unbalanced grid voltage, and iii) high probability of successful grid FRT. The effectiveness of the proposed solution is confirmed through simulation studies on 2MW DFIG.