• Title/Summary/Keyword: magnitude of cancer

Search Result 75, Processing Time 0.037 seconds

Reconstruction of Through and Through Defect of the Cheek After Resection of Buccal Mucosa Cancer (협점막암 절제후 협부관통결손의 재건방법에 대한 고찰)

  • Choi Eun-Chang;Kim Eun-Seo;Hong Won-Pyo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.11 no.1
    • /
    • pp.47-55
    • /
    • 1995
  • A large lateral facial defects especially a through and through defect of the cheek remains as challenging field of reconstruction for the head and neck surgeons. Closure of these wounds is technically troublesome due to the magnitude and location of the soft tissue and skin defect, functional and aesthetic consideration. optimal cancer surveillance, and desire for good nourishment. Most traditional methods dealing with these defects, including split-thickness skin graft, local and regional flaps as well as musculocutaneous flaps have their limitations. We applied four different methods for these reconstruction in four cases. We utilized temporal muscle flap, forearm free flap and secondary healing for repair of mucosal defects, and medial base cervicopectoral flap, pectoralis major myocutaneous flap and cervicofacial flap for the reconstruction of external skin defects. In one case, both sides were reconstructed with single forearm free flap. In our experiences, secondary healing could be one of the useful method for mucosal repair in the defect between upper and lower gingivobuccal sulcus. However, forearm free flap was thought to be more ideal for the cases with mandibulectomy. For the external repair, the regional skin flap was considered to be superior to pectoralis major myocutaneous flap or forearm free flap especially on color matching.

  • PDF

Investigation on Individual Variation of Organ Doses for Photon External Exposures: A Monte Carlo Simulation Study

  • Yumi Lee;Ji Won Choi;Lior Braunstein;Choonsik Lee;Yeon Soo Yeom
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.50-64
    • /
    • 2024
  • Background: The reference dose coefficients (DCs) of the International Commission on Radiological Protection (ICRP) have been widely used to estimate organ doses of individuals for risk assessments. This approach has been well accepted because individual anatomy data are usually unavailable, although dosimetric uncertainty exists due to the anatomical difference between the reference phantoms and the individuals. We attempted to quantify the individual variation of organ doses for photon external exposures by calculating and comparing organ DCs for 30 individuals against the ICRP reference DCs. Materials and Methods: We acquired computed tomography images from 30 patients in which eight organs (brain, breasts, liver, lungs, skeleton, skin, stomach, and urinary bladder) were segmented using the ImageJ software to create voxel phantoms. The phantoms were implemented into the Monte Carlo N-Particle 6 (MCNP6) code and then irradiated by broad parallel photon beams (10 keV to 10 MeV) at four directions (antero-posterior, postero-anterior, left-lateral, right-lateral) to calculate organ DCs. Results and Discussion: There was significant variation in organ doses due to the difference in anatomy among the individuals, especially in the kilovoltage region (e.g., <100 keV). For example, the red bone marrow doses at 0.01 MeV varied from 3 to 7 orders of the magnitude depending on the irradiation geometry. In contrast, in the megavoltage region (1-10 MeV), the individual variation of the organ doses was found to be negligibly small (differences <10%). It was also interesting to observe that the organ doses of the ICRP reference phantoms showed good agreement with the mean values of the organ doses among the patients in many cases. Conclusion: The results of this study would be informative to improve insights in individual-specific dosimetry. It should be extended to further studies in terms of many different aspects (e.g., other particles such as neutrons, other exposures such as internal exposures, and a larger number of individuals/patients) in the future.

Quantification of Her-2/Neu Gene in Breast Cancer Patients using Real Time-Polymerase Chain Reaction (Q-PCR) and Correlation with Immunohistochemistry Findings

  • Abdul Murad, Nor Azian;Razak, Zuraini Abdul;Hussain, Rosniza Muhammmad;Syed Hussain, Sharifah Noor Akmal;Ching Huat, Clarence Ko;Siti Aishah, Che Md. Ali;Abdullah, Norlia;Muhammad, Rohaizak;Ibrahim, Naqiyah;Jamal, Rahman
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1655-1659
    • /
    • 2013
  • Background: HER-2/neu is a proto-oncogene that encodes a transmembrane tyrosine kinase growth factor which is crucial for stimulating growth and cellular motility. Overexpression of HER-2/neu is observed in 10-35% of human breast cancers and is associated with pathogenesis, prognosis as well as response to therapy. Given the imperative role of HER-2/neu overexpression in breast cancer, it is important to determine the magnitude of amplification which may facilitate a better prognosis as well as personalized therapy in affected patients. In this study, we determined HER-2/neu protein expression by immunohistochemistry (IHC) concurrently with HER-2/neu DNA amplification by quantitative real time-polymerase chain reaction (Q-PCR). Materials and Methods: A total of 53 paired tissue samples from breast cancer patients were frozen-sectioned to characterize the tumour and normal tissues. Only tissues with 80% tumour cells were used in this study. For confirmation, Q-PCR was used to determine the HER-2/neu DNA amplification. Results: We found 20/53 (37.7%) of the tumour tissues to be positive for HER-2/neu protein overexpression using IHC. Out of these twenty, only 9/53 (17%) cases were in agreement with the Q-PCR results. The concordance rate between IHC and Q-PCR was 79.3%. Approximately 20.7% of positive IHC cases showed no HER-2/neu gene amplification using Q-PCR. Conclusion: In conclusion, IHC can be used as an initial screening method for detection of the HER-2/neu protein overexpression. Techniques such as Q-PCR should be employed to verify the IHC results for uncertain cases as well as determination of HER-2/neu gene amplification.

Review of the Radiation Risk and Clinical Efficacy Associated with Computed Tomography Cancer Screening (암의 조기발견을 위한 CT촬영에서의 임상적 효능과 방사선위해에 대한 고찰)

  • Kim, Hyun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.214-227
    • /
    • 2013
  • Computed tomographic scan as a screening procedures in asymptomatic individuals has seen a steady increase with the introduction of multiple-raw detector CT scanners. This report provides a brief review of the current controversy surrounding CT cancer screening, with a focus on the radiation induced cancer risks and clinical efficacy. 1. A large study of patients at high risk of lung cancer(the National Lung Screening Trial[NLST]) showed that CT screening reduced cancer deaths by 20%(1.33% in those screened compared with 1.67% in those not screened). The rate of positive screening tests was 24.2% and 96.4% of the positive screening results in the low-dose CT group were false-positive. Radiation induced lung cancer risk was estimated the most important in screening population because ERR of radiation induced lung cancer does not show the decrease with increasing age and synergistic connection between smoking and radiation risk. Therefore, the radiation risk may be on the same order of magnitude as the benefit observed in the NLST. Optimal screening strategy remain uncertain, CT lung cancer screening is not yet ready for implementation. 2. Computed tomographic colonography is as good as colonoscopy for detecting colon cancer and is almost as good as colonoscopy for detecting advanced adenomas, but significantly less sensitive and specific for smaller lesions and disadvantageous for subsequent therapeutic optical colonoscopy if polyps are detected. The average effective dose from CT colonography was estimated 8-10 $mS{\nu}$, which could be a significant dose if administered routinely within the population over many years. CT colonography should a) achieve at least 90% sensitivity and specificity in the size category from 6 and 10 mm, b) offer non-cathartic bowl preparation and c) be optimized and standardized CT parameters if it is to be used for mass screening. 3. There is little evidence that demonstrates, for whole-body scanning, the benefit outweighs the detriment. This test found large portion of patient(86~90.8%) had at least one abnormal finding, whereas only 2% were estimated to have clinically significant disease. Annual scans from ages 45 to 75 years would accrue an estimated lifetime cancer mortality risk of 1.9%. There is no group within the medical community that recommends whole-body CT. No good studies indicate the accuracy of screening CT, at this time. The benefit/risk balance for any of the commonly suggested CT screening techniques has yet to be established. These areas need further research. Therefore wild screening should be avoided.

Endogenous Nitric Oxide Strengthens Doxorubicin-induced Apoptosis in Human Colorectal Cell Lines (Doxorubicin에 의한 내인성 산화질소가 인간 대장암 세포주에서의 세포사멸에 미치는 효과)

  • Im, Soon Jae;Kim, Ji Hye;Kim, Min Young
    • Journal of Life Science
    • /
    • v.24 no.10
    • /
    • pp.1137-1143
    • /
    • 2014
  • Doxorubicin is a general chemotherapy drug widely used for a number of cancers. However, the correlation between endogenous nitric oxide ($NO^{\bullet}$) levels and chemoresistance to doxorubicin remains unclear. In this study, we investigated the effect of endogenous $NO^{\bullet}$ on the anticancer activity of doxorubicin in human colon cancer cell lines HCT116 and HT29 with different p53 status. The cells were treated with either doxorubicin alone or in combination with the $NO^{\bullet}$ synthase (NOS) inhibitor $N^G$-monomethyl-L-arginine (NMA). Doxorubicin differentially inhibited the growth of both the HCT116 (p53-WT) and HT29 (p53-MUT) cells, which was mitigated by cotreatment with NMA. Further studies revealed that inhibition of endogenous $NO^{\bullet}$ mitigated doxorubicin-induced apoptosis in the HCT116 and HT29 cells, as evidenced by apoptotic DNA fragmentation and the sub-G1 peak of apoptotic markers. Apoptosis was delayed in the HT29 cells, and its magnitude was greatly reduced, underscoring the importance of the modulation of p53 in the response. RT-PCR analysis revealed that doxorubicin down-regulated levels of inhibitors of the apoptosis family (cellular IAP-1 and-2). Collectively, these data show that induction of apoptosis by doxorubicin in human colon cancer cells is possibly related to modulation of endogenous $NO^{\bullet}$, the expression of the IAP family of genes, and the status of p53. The underlying mechanisms may represent potential targets for adjuvant strategies to improve the efficacy of chemotherapy for colon cancer.

Reproducibility evaluation of the use of pressure conserving abdominal compressor in lung and liver volumetric modulated arc therapy (흉복부 방사선 치료 시 압력 기반 복부압박장치 적용에 따른 치료 간 재현성 평가)

  • Park, ga yeon;Kim, joo ho;Shin, hyun kyung;Kim, min soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose: To evaluate the inter-fractional position and respiratory reproducibility of lung and liver tumors using pressure conserving type(P-type) abdominal compressor in volumetric modulated arc therapy(VMAT). Materials and methods: Six lung cancer patients and three liver cancer patients who underwent VMAT using a P-type abdominal compressor were included in this study. Cone-beam computed tomography(CBCT) images were acquired before each treatment and compared with planning CT images to evaluate the inter-fractional position reproducibility. The position variation was defined as the difference of position shift values between target matching and bone matching. 4-dimensional cone-beam computed tomography(4D CBCT) images were acquired weekly before treatment and compared with planning 4DCT images to evaluate the inter-fractional respiratory reproducibility. The respiratory variation was calculated by the magnitude of excursions by breathing. Results: The mean ± standard deviation(SD) of overall position variation values, 3D vector in the three translational directions were 1.1 ± 1.4 mm and 4.5 ± 2.8 mm for the lung and liver, respectively. The mean ± SD of respiratory variation values were 0.7 ± 3.4 mm (p = 0.195) in the lung and 3.6 ± 2.6 mm (p < 0.05) in the liver. Conclusion: The use of P-type compressor in lung and liver VMAT was effective for stable control of inter-fractional position and respiratory variation by reproduction of abdominal compression. Appropriate PTV margin must be considered in treatment planning, and image guidance before each treatment are required in order to obtain more stable reproducibility

Measurement of Variation in Water Equivalent Path Length by Respiratory Organ Movement

  • Minohara, Shinichi;Kanai, Tatsuaki;Endo, Masahiro;Kato, Hirotoshi;Miyamoto, Tadaaki;Tsujii, Hirohiko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.90-93
    • /
    • 2002
  • In particle radiotherapy, a shape of the beam to conform the irradiation field is statically defined by the compensator, collimator and potal devices at the outside of the patient body. However the target such as lung or liver cancer moves along with respiration. This increases the irradiated volume of normal tissue. Prior discussions about organ motions along with respiration have been mainly focused on inferior-superior movement that was usually perpendicular to beam axis. On the other hand, the change of the target depth along the beam axis is very important especially in particle radiotherapy, because the range end of beam (Bragg peak) is so sharp as to be matched to distal edge of the target. In treatment planning, the range of the particle beam inside the body is calculated using a calibration curve relating CT number and water equivalent path length (WEL) to correct the inhomogeneities of tissues. The variation in CT number along the beam path would cause the uncertainties of range calculation at treatment planning for particle radiotherapy. To estimate the uncertainties of the range calculation associated with patient breathing, we proposed the method using sequential CT images with respiration waveform, and analyzed organ motions and WELs at patients that had lung or liver cancer. The variation of the depth along the beam path was presented in WEL rather than geometrical length. In analyzed cases, WELs around the diaphragm were remarkably changed depending on the respiration, and the magnitude of these WEL variations was almost comparable to inferior-superior movement of diaphragm. The variation of WEL around the lung was influenced by heartbeat.

  • PDF

Secondary Neutron Dose Measurement for Proton Line Scanning Therapy

  • Lee, Chaeyeong;Lee, Sangmin;Chung, Kwangzoo;Han, Youngyih;Chung, Yong Hyun;Kim, Jin Sung
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.162-168
    • /
    • 2016
  • Proton therapy is increasingly being actively used in the treatment of cancer. In contrast to photons, protons have the potential advantage of delivering higher doses to the cancerous tissue and lower doses to the surrounding normal tissue. However, a range shifter is needed to degrade the beam energy in order to apply the pencil beam scanning technique to tumors located close to the minimum range. The secondary neutrons are produced in the beam path including within the patient's body as a result of nuclear interactions. Therefore, unintended side effects may possibly occur. The research related to the secondary neutrons generated during proton therapy has been presented in a variety of studies worldwide, since 2007. In this study, we measured the magnitude of the secondary neutron dose depending on the location of the detector and the use of a range shifter at the beam nozzle of the proton scanning mode, which was recently installed. In addition, the production of secondary neutrons was measured and estimated as a function of the distance between the isocenter and detector. The neutron dose was measured using WENDI-II (Wide Energy Neutron Detection Instruments) and a Plastic Water phantom; a Zebra dosimeter and 4-cm-thick range shifter were also employed as a phantom. In conclusion, we need to consider the secondary neutron dose at proton scanning facilities to employ the range shifter reasonably and effectively.

Measuring Workload of Home Visit Care Activities Using Relative Values (방문요양 행위 업무량의 상대적 가치 측정)

  • Han, Seong-Ok;Park, Eun-Cheol;Kang, Dae-Ryong;Kang, Im-Ok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.41 no.5
    • /
    • pp.331-338
    • /
    • 2008
  • Objectives : The purpose of this study was to measure the workload of home visit care activities and their relative values. This study examined also factors that affect the workload of home visit care activities. Methods : The participants of this study were 126 home-helpers of 50 home visit care agencies at the 2nd Long-term Care Insurance Demonstration Project. The workload of home visit care activities was divided into total work and four dimensions ; physical efforts, mental efforts, stress and time. Home visit care activities consisted of four categories with 24 items. We used magnitude estimation method to measure their relative values of the four dimensions. The participants answered the relative values of each activities based on the reference service. We used the activity for supporting their elderly's evacuation as the reference service. Results : Most of the respondents were over 40 years old female. They consumed most their time supporting elderly's going out. They consumed their highest physical, mental efforts, and stress for activities of coping with emergency situation. The Pearson correlation coefficients showed significant relationships between workload and each dimensions. This study showed that all four dimensions are statistically significant predictors of workload of home visit care activities. Also, we found that the home-helper's career affects the workload of home visit care activities. Conclusions : The workload of home visit care activities could be explained by physical efforts, mental efforts, stress and time.

The Single Cigarette Economy in India - a Back of the Envelope Survey to Estimate its Magnitude

  • Lal, Pranay;Kumar, Ravinder;Ray, Shreelekha;Sharma, Narinder;Bhattarcharya, Bhaktimay;Mishra, Deepak;Sinha, Mukesh K.;Christian, Anant;Rathinam, Arul;Singh, Gurbinder
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.13
    • /
    • pp.5579-5582
    • /
    • 2015
  • Background: Sale of single cigarettes is an important factor for early experimentation, initiation and persistence of tobacco use and a vital factor in the smoking epidemic in India as it is globally. Single cigarettes also promote the sale of illicit cigarettes and neutralises the effect of pack warnings and effective taxation, making tobacco more accessible and affordable to minors. This is the first study to our knowledge which estimates the size of the single stick market in India. Materials and Methods: In February 2014, a 10 jurisdiction survey was conducted across India to estimate the sale of cigarettes in packs and sticks, by brands and price over a full business day. Results: We estimate that nearly 75% of all cigarettes are sold as single sticks annually, which translates to nearly half a billion US dollars or 30 percent of the India's excise revenues from all cigarettes. This is the price which the consumers pay but is not captured through tax and therefore pervades into an informal economy. Conclusions: Tracking the retail price of single cigarettes is an efficient way to determine the willingness to pay by cigarette smokers and is a possible method to determine the tax rates in the absence of any other rationale.