• 제목/요약/키워드: magnification

검색결과 692건 처리시간 0.02초

인상채득 후 시간경과에 따른 고무인상재의 체적변화 (AN EVALUATION OF THE TIME-DEPENDENT DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS)

  • 이홍석;조석규;윤태호;박주미;송광엽
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.363-373
    • /
    • 2006
  • Statement of Problem : The accuracy and dimensional stability of elastomeric impression materials have been the subject of numerous investigation. Few studies have addressed the effect of changes in time on the dimensional stability of impression materials. Purpose: The purpose of this investigation was to evaluate the effects of elastomeric impression materials and storage time on dimensional stability. Materials and methods: A total of 75 impressions were made of epoxy resin dies mimicked prepared 3-unit fixed partial denture. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines and interpreped dot. Impression materials investigated included two polyether impression materials and three polyvinylsiloxane impression material. 15 specimens were made of each impression material and poured by type IV stone over times (30 minutes, 24 hours, 72 hours) after mixing; the same examiner measured each specimen 3 times at a magnification of 3.5$\times$. All statistical tests were performed with the level of significance set at .05. Results : The results indicated that significant difference at any measuring point of stone dies of the polyether impression materials and when measurements at 30 minutes, 24 hours, and 72 hours were compared ; the length of measuring point increased significantly as time passed by. However this result is not significant clinically. Analysis also showed significant differences at any measuring point when polyvinylsiloxane and polyether impression materials were compared and significant differences clinically. Conclusion: Under the conditions of this study, the shrinkage rate of the polyvinylsiloxane and polyether impression materials significantly increased as time passed by. The polyether impression materials showed higher shrinkage significantly, while the shrinkage rate of all five materials showed a significant time-dependent increase.

Effect of anatomic, semi-anatomic and non-anatomic occlusal surface tooth preparations on the adaptation of zirconia copings

  • Habib, Syed Rashid;Asiri, Waleed;Hefne, Mohammed Jameel
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.444-450
    • /
    • 2014
  • PURPOSE. To compare the accuracy of marginal and internal adaptation of zirconia (Zr) copings fabricated on anatomic (A), semi-anatomic (SA) and non-anatomic (NA) occlusal surface preparations. MATERIALS AND METHODS. 45 extracted bicuspid teeth were prepared for receiving zirconia crowns, with different occlusal preparation designs A=15, SA=15 & NA=15. The Zr copings were fabricated by using CAD4DENT, CAD/CAM. The copings were adjusted, cemented and were cross sectioned centrally from buccal cusp tip to lingual cusp tip into mesial and distal halves. The copings were examined under electron microscope at ${\times}200$ magnification and the measurements were recorded at 9 predetermined areas in micrometers. RESULTS. Overall mean gap values for the three groups was found to be $155.93{\pm}33.98{\mu}m$ with Anatomical Occlusal preparation design having the least gap value of $139.23{\pm}30.85{\mu}m$ showing the best adaptation among the groups. Post Hoc Tukey's test showed a statistically significant difference (P=.007) between the means of gap for A & NA preparation designs. Measurements recorded at 9 predetermined points showed variations for the three groups. CONCLUSION. Anatomical occlusal preparation designs resulted in better marginal and internal adaptation of Zr copings. There is a considerable variation between the measured marginal and internal gap values for the Zr copings fabricated by the (CAD4DENT-CAD/CAM). This variation may be associated with the lack of standardization of the preparation of teeth, computerized designing of the coping for each tooth, cement used, uniform pressure application during the cementation of the copings, sectioning of the copings and the microscopic measurements.

단근 소구치의 근관계 형태에 따른 치근단 부위의 근관 형태 (The apical root canal shape according to the root canal system of premolars with single root)

  • 박민수;황호길;조형훈
    • 대한치과의사협회지
    • /
    • 제55권1호
    • /
    • pp.63-70
    • /
    • 2017
  • Materials and methods: Sixty extracted premolars were assigned to three groups according to the root canal system (Weine's classification; type I, II and III) of 20 teeth each using radiographic examination. The root tip was cut horizontally 1 mm from the anatomical apex and the apical cross-section was visualized using microscope at x50 magnification and photographed. Minimum and maximum apical root canal diameter of each tooth was measured and classified into three types by canal morphology (round, oval and flattened shape). Statistical analysis was performed to compare the apical root canal diameter and morphology according to the root canal system. Results: In apical root canal morphology at cross-sectional view, the most common shape was round in type I, flat in type II, and oval in type III. In apical root canal diameters at cross-sectional view, there was a significant difference between the minimum and maximum diameter in all types (p<0.05). The maximum diameter was 0.331 mm in type I, 0.519 mm in type II, and 0.310 mm in type III. There was a significant difference among type I, III and type II (p<0.05). Conclusion: The morphology and diameter of apical root canal was different according to the root canal system. Therefore, clinicians should consider the apical file size in view of the apical root canal shape according to the root canal system.

  • PDF

지르코니아의 소결 후 특성 (Surface Characteristics of Ground and Post-Sintered Zirconia)

  • 김민정;김임선;최병환;김원기
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.157-163
    • /
    • 2016
  • Purpose: It is to compare and evaluate the change of the wear rate and phase variation of the Zirconia before and after the sintering after the grinding by a high speed equipment manufactured for the Zirconia. Methods: The specimen of the sintered Zirconia was manufactured as size of $15mm{\times}15mm{\times}2mm$. The grinding has been applied to each of all pieces of each test groups for a minute fit for each condition at same speed of 50,000 rpm by a diamond bur at high speed handpiece with injection of the air and water. For the observation of the surface before and after the sintering of the each test piece, the cross section of it was observed as 100 magnification by a scanning electron microscope after it was coated by PT, and the diffraction analysis was performed by XDR to compare the crystal phase of the Zirconia. The average surface roughness value of all specimens were evaluated. The wear test was performed at room temperature by applying a load of 1kg for 120,000 cycles for the chewing period 6 months. Wear was analyzed for the enamel cusps by measurement of the vertical substance loss with a laser scanner. Conclusion: The phase variation from the tetragonal phase to the monoclinic phase was confirmed in the test group of the pre-sintered Zirconia after the grinding, and the value of the surface roughness and the wear rate was increased in experimental group.

3차 회선 보간법에 적응적 매개변수를 적용한 영상 보간 (An Image Interpolation by Adaptive Parametric Cubic Convolution)

  • 유재욱;박대현;김윤
    • 한국컴퓨터정보학회논문지
    • /
    • 제13권6호
    • /
    • pp.163-171
    • /
    • 2008
  • 본 논문에서는 고화질, 고해상도로 영상을 확대하기 위한 적응적인 매개변수가 적용된 3차 회선 보간법을 제안한다. 제안하는 보간법에서는 영상이 가지는 주파수 특성을 반영한 보간을 수행하기 위해 1단계 보간 과정에서 새롭게 정의한 비용함수를 이용하여 3차 회선 보간법의 매개변수를 적응적으로 구하고, 2단계 보간 과정에서는 1단계에서 구한 적응적인 매개변수를 적용하여 3차 회선 보간법을 수행한다. 영상의 주파수 특성이 고려된 적응적인 매개변수의 사용은 보간 커널의 성능을 향상시켜 동일한 매개변수를 사용하는 이전의 3차 회선 보간법보다 결과 영상의 화질이 우수하다. 컴퓨터 실험 결과를 통해 제안하는 보간법이 이전의 보간법들보다 PSNR이 약 $0.5{\sim}4dB$ 높아 객관적인 성능에서 나은 결과를 나타냈으며, 결과 영상의 확대를 통한 비교에서 영상이 부드럽고 에지가 선명하게 나타남으로 주관적 화질이 우수함을 보였다.

  • PDF

초등학교 학교조경의 환경교육적 활용을 위한 기초 연구 -성남시 교사들의 인식을 중심으로- (A Basic Study for the Environmental Educational Use of Elementary School Landscape -The Awareness of Seongnam City Elementary School Teacher-)

  • 김인호;안동만
    • 한국환경교육학회지:환경교육
    • /
    • 제11권2호
    • /
    • pp.224-237
    • /
    • 1998
  • The purpose of this study that was based on the theory review about the practical use necessity of school landscape was to survey on the awareness of elementary school teachers about the applications of school landscape for environmental education. This study was carried out through the review of literature, the questionnaire to 132 elementary school teachers in Seongnam City. The findings derived from this study were as follows : First, School landscape is an important field as environmental education resource for the improvement of school environmental education. Especially, for the improvement of environmental sensitivity through field-experience learning, the practical applications of elementary school landscape is very important and urgent in aspects of environmental education theory, accessibility, and convenience. Second, Most of responded teachers give an affirmative answer about the field-experience learning for school environmental education and the necessity of practical use of school landscape for field-experience learning. Several the improvement to use elementary school landscape for environmental education being suggested by teachers are the increase of financial support, the magnification of school area, and the school landscape planning and design in consideration of environmental education by landscape architect expert. Third, Above half of teachers don't agree to use the roof garden for environmental education because of the safety of students and the school building construction. Fourth, Teachers are more satisfied with the status of school landscape maintenance than the practical usability of school landscape in aspect of environmental education and the facilities in school landscape. Teachers think that the most important functions and roles of school landscape is psychological factor.

  • PDF

CCD 카메라가 장착된 광학현미경을 사용한 폴리스티렌구 (3 $\mu$m와 10 $\mu$m)의 평균지름측정 (Improvement of size measurement polystyrene spheres of diameters 3$\mu$m and 10$\mu$m by optical microscope with CCD camera)

  • 정기영;박병천;깅주식;송원영;오범환
    • 한국광학회지
    • /
    • 제9권6호
    • /
    • pp.362-367
    • /
    • 1998
  • 중심거리측정법은 서로 붙어있는 두 입자 중심점간의 거리를 측정하여 입자의 지름을 구하는 방법이다. 표면장력에 의해 배열이 형성된 시편 입자들의 초점군을 투과식 광학현미경에 평행 레이저광을 입사시켜 얻어내고 CCD 카메라로 영상을 받아 전산 분석하였다. Global lab image라는 영상처리 프로그램으로 초점들의 중심점을 찾고 붙어있는 입자들의 중심점간 거리를 화소(CCD 카메라의 pixel)단위로 계산하였으며, 화소의 좌표는 레이저 간섭계로 변위를 읽는 이송대를 이용하여 교정하였다. 기존의 측정방법을 개선하여 빠른 시간에 간편하게 측정하면서도 표준입자의 배율고정에 충분한 불확도를 얻을 수 있었다. 본 실험에는 NIST 인증물질인 3$\mu\textrm{m}$와 10$\mu\textrm{m}$ 폴리스티렌구(NIST SRM 1962, 1960)를 측정하였으며, 1%이하의 불확도(신뢰도 99% 수준)로써 NIST 결과와비교하였다.

  • PDF

320×240 적외선 검출기를 이용한 열상센서의 설계 (Thermal imaging sensor design using 320×240 IRFPA)

  • 홍석민;송인섭;김창우;유위경;김현숙
    • 한국광학회지
    • /
    • 제15권5호
    • /
    • pp.423-428
    • /
    • 2004
  • 320${\times}$240 배열의 중적외선 대역(3.7 $\mu\textrm{m}$∼4.8 $\mu\textrm{m}$) MCT(HgCdTe) 검출기를 이용하여 분해능과 신뢰도가 대폭 향상된 소형$.$고성능의 적외선 열상센서를 설계, 제작하였다. 개발된 열상센서는 1∼20배의 고배율 줌 광학계로 설계하고 미세주사 기법을 적용하여 640${\times}$480의 화소를 재현하여 항공기의 항법 보조로부터 표적획득에 이르기까지 다양한 활용이 가능하다. 적용된 적외선 줌 광학계는 릴레이 형태의 재결상계로 설계되었으며 미세주사 장치의 개발로 7.6 cycles/mrad 까지 분해가 가능하며 최저배율에서 40$^{\circ}$${\times}$30$^{\circ}$의 초광각(super wide field of view)의 시계를 갖는다. 또한 불균일 보정기법과 히스토그램 가변방식의 결합을 통한 첨단 열 영상처리 기법을 제안하여 열상센서에 적용함으로써 고성능의 실시간 디지털 영상처리를 가능케 하였다. 본 신호처리기의 개발을 통해 획득된 열영상의 최소분해가능 온도차는 고배율에서 0.05K(@1cycles/mrad) 이하의 우수한 결과를 보였다.

수종의 역충전 재료의 치근단 밀폐력 비교 (COMPARISON OF THE SEALING ABILITY OF VARIOUS RETROGRADE FILLING MAIERIALS)

  • 황윤찬;강인철;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.379-386
    • /
    • 2001
  • This study was performed to evaluate the sealing ability of various retrograde filling materials by using bacterial penetration and dye penetration test. One hundred and forty extracted human teeth with single, straight canals and mature apiece were collected and used for this study. All canals were instrumented using an engine driven Ni-Ti file (ProFile). After removing 3mm from the apex of tooth, a standardized 3mm root end cavity was prepared using an ultrasonic instrument. The 70 teeth were randomly divided into 7 groups : 6 groups for retrograde filling using Super-EBA, ZOE, Chelon-Silver, IRM, ZPC and amalgam. The 7th group was used as a negative control. Nail varnish was applied to all external root surfaces to the level of the reseated root ends to prevent lateral microleakages. The specimens were then sterilized in an ethylene oxide sterilizer for 24 hours. 2 mm of the reseated root was immersed in a culture chamber containing a Tripticase Soy Broth with a phenol red indicator. The coronal access of each specimen was inoculated every 72 hours with suspension of Proteus vulgaris. The culture media were observed every 24hours for color change indicating bacterial contamination. The specimens were observed for 4weeks. The remaining 70 teeth were submitted to a dye penetration test. The canals of all teeth were first sealed with AH26 and obturated using an Obtura II system. Root resection, root end preparation and retrograde filling was performed as above. All specimens were suspended in 2% methylene blue dye for 72 hours before being ion gitudinally split. The degree of dye penetration was then measured using a stereomicroscope at 10 magnification and evaluated. The results were as floows : 1. In the bacterial penetration, the degree of leakage was the lowest in the Super-EBA, followed by, in ascending order, ZOE, Chelon-Silver IRM and ZPC. The amalgam showed highest bacterial leakage of all(p<0.01). 2. In the dye penetration, the degree of microleakage was the lowest in the Chelon-Silver and Super-EBA, followed by, in ascending order, IRM, ZPC. The ZOE and amalgam showed the highest microleakage of all (p<0.05). These results suggested that the eugenol based cement, Super-EBA, have excellent sealing ability as a retrograde filling material.

  • PDF

측방가압법과 System BTM를 이용한 근관충전시 근관만곡도에 따른 폐쇄효과의 비교 (COMPARISON OF THE INFLUENCE OF CANAL CURVATURE ON THE SEALING ABILITY OF LATERAL CONDENSATION AND SYSTEM BTM)

  • 임동열;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.482-489
    • /
    • 1999
  • The purpose of this study was to compare sealing ability between lateral condensation and continuous wave of condensation in depend of root canal curvature. In this study, we divided fifty-six human molar teeth into two group in depend of Schneider method, and then subdivided them into four experimental group (each group is composed of twelve teeth) by canal curvature and obturation method, and eight teeth were served as positive and negative controls. Specimens were prepared by Quantac 2000 series file and obturated by lateral condensation or System B. Specimens were immersed in india ink for 7 days, decalcified by 10% nitric acid, dehydrated by 75, 95 and 100% alcohol in order, cleared by methyl salicylate and then measured of dye penetration with stereomicroscope(${\times}6.5$ magnification) and Image Pro plus. The data were analyzed stastically by one-way ANOVA and Scheffe test. The data were as follows: 1. The mean leakage was $0.725{\pm}1.167$ for group A, $0.813{\pm}0.921$ for group B, $0.809{\pm}0.997$ for group C, $1.111{\pm}1.147$ for group D, but no significant difference among them(p>0.05). 2. Lateral condensation had better sealing ability than continuous wave of condensation, but no significant difference among them(p>0.05). 3. There was no significant difference between root canal curvature degree and microleakage(p>0.05).

  • PDF