• 제목/요약/키워드: magnification

검색결과 689건 처리시간 0.024초

Determination of Absorbed Dose for Gafchromic EBT3 Film Using Texture Analysis of Scanning Electron Microscopy Images: A Feasibility Study

  • So-Yeon Park
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.158-163
    • /
    • 2022
  • Purpose: We subjected scanning electron microscopic (SEM) images of the active layer of EBT3 film to texture analysis to determine the dose-response curve. Methods: Uncoated Gafchromic EBT3 films were prepared for direct surface SEM scanning. Absorbed doses of 0-20 Gy were delivered to the film's surface using a 6 MV TrueBeam STx photon beam. The film's surface was scanned using a SEM under 100× and 3,000× magnification. Four textural features (Homogeneity, Correlation, Contrast, and Energy) were calculated based on the gray level co-occurrence matrix (GLCM) using the SEM images corresponding to each dose. We used R-square to evaluate the linear relationship between delivered doses and textural features of the film's surface. Results: Correlation resulted in higher linearity and dose-response curve sensitivity than Homogeneity, Contrast, or Energy. The R-square value was 0.964 for correlation using 3,000× magnified SEM images with 9-pixel offsets. Dose verification was used to determine the difference between the prescribed and measured doses for 0, 5, 10, 15, and 20 Gy as 0.09, 1.96, -2.29, 0.17, and 0.08 Gy, respectively. Conclusions: Texture analysis can be used to accurately convert microscopic structural changes to the EBT3 film's surface into absorbed doses. Our proposed method is feasible and may improve the accuracy of film dosimetry used to protect patients from excess radiation exposure.

길이 표준 소급성을 갖는 원자간력 현미경을 이용한 2차원 격자 시편 측정과 불확도 평가 (Measurements of Two-dimensional Gratings Using a Metrological Atomic Force Microscope and Uncertainty Evaluation)

  • 김종안;김재완;강주식;엄태봉
    • 한국정밀공학회지
    • /
    • 제24권9호
    • /
    • pp.68-75
    • /
    • 2007
  • The pitch and orthogonality of two-dimensional (2D) gratings have been measured by using a metrological atomic force microscope (MAFM) and measurement uncertainty has been analyzed. Gratings are typical standard artifacts for the calibration of precision microscopes. Since the magnification and orthogonality in two perpendicular axes of microscopes can be calibrated simultaneously using 2D gratings, it is important to certify the pitch and orthogonality of 2D gratings accurately for nano-metrology using precision microscopes. In the measurement of 2D gratings, the MAFM can be used effectively for its nanometric resolution and uncertainty, but a new measurement scheme was required to overcome some limitations of current MAFM such as nonnegligible thermal drift and slow scan speed. Two kinds of 2D gratings, each with the nominal pitch of 300 nm and 1000 nm, were measured using line scans for the pitch measurement of each direction. The expanded uncertainties (k = 2) of measured pitch values were less than 0.2 nm and 0.4 nm for each specimen, and those of measured orthogonality were less than 0.09 degree and 0.05 degree respectively. The experimental results measured using the MAFM and optical diffractometer were coincident with each other within the expanded uncertainty of the MAFM. As a future work, we also proposed another scheme for the measurements of 2D gratings to increase the accuracy of calculated peak positions.

하악관에 관한 방사선학적 연구 (A RADIOGRAPHIC STUDY ON THE MANDIBULAR CANAL)

  • 조성은;김재덕
    • 치과방사선
    • /
    • 제21권2호
    • /
    • pp.307-316
    • /
    • 1991
  • The purpose of this study is to improve the availabilities of radiographic technics as diagnostic method related to mandibular canal in dental clinic. For this study 12 dry mandibles were used and 12 orthopantomograms were taken for measuring the gonial angle and the angle of mandibular canal to inferior border of mandible. 12 sites located between the 1st premolar to the 3rd molar region of 3dry mandibles were selected randomly, for measuring the vertical image magnification rates on three films; intraoral film, orthopantomogram, and computed tomogram, respectively and the thickness of cortical bone, and for observing bucco-lingually and supero-inferiorly location of the mandibular canal. The acquired results were as follows: 1. The means of the gonial angle and the angle of mandibular canal to inferior border of mandible were 123.9° and 143.5° And the two angles of dry mandible in alveolar crest stage were greater than in alveolar socket stage. 2. The vertical image length on intraoral film by paralleling technic was magnified by 3.07% on the average, the length on orthopantomogram by 18.49%, and the length on computed tomogram by 0.27%. 3. Observation of the bucco-lingually positional relationship of the mandibular canal was impossible by occlusal projection with the cross section technic and intraoral standard projection with the Clack's rule, however, possible by computed tomogram. 4. The thickness of the cortical bone of mandible was thickest in inferior border, and thicker by 6.59% at buccal side than at lingual side.

  • PDF

상악동의 형태에 관한 방사선학적 연구 (A RADIOGRAPHIC STUDY ON THE MORPHOLOGY OF THE MAXILLARY SINUS)

  • 김봉영;김재덕
    • 치과방사선
    • /
    • 제21권2호
    • /
    • pp.297-306
    • /
    • 1991
  • The purpose of this study is to improve the availabilities of radiographic technics as diagnostic methods to evaluate maxillary sinus in dental clinic. For the morphologic study of maxillary sinus, 20 dry maxillas were used and intraoral standard views, orthopantomograms, and skull P-A views were taken. For measuring the vertical image magnification rates, 5 sites in maxillary molar regions of 5 dry mandibles were selected radndomly and 25 wires of the determined sizes for selected portions were attached to the sites, after then, intraoral radiograms with bisecting technic and orthopantomograms were taken. The acquired results were as follows: 1. The anterior extension of the maxillary sinus on orthopantomogram was the distal side of the canine in 45.45% of subjects, the mesial side of the canine in 27.27%, the lateral incisor in 9.09%, the mesial side of the 1st premolar in 9.09%, and the mesial side of the 2nd pre-molar in 9.09%. 2. The positional relationship between the floor of maxillary sinus and the apex of alveolar socket revealed superimposed type in 58.3% of subjects, approached type in 33.3%, and separated type in 8.4%. 3. The morphology of inferior border of maxillary sinus was simple V or U shape in edentulous stage and V or wide U shape in alveolar socket stage. 4. The vertical image length on intraoral film taken by bisecting technic was magnified by 27.23% on the average and the length on orthopantomogram by 12.35%. 5. The inferior borders of maxillary sinus coinciding with each of the areas bearing the anterior and the posterior teeth on skull P-A view were determined.

  • PDF

Apical foramen morphology according to the length of merged canal at the apex

  • Kim, Hee-Ho;Min, Jeong-Bum;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • 제38권1호
    • /
    • pp.26-30
    • /
    • 2013
  • Objectives: The aim of this study was to investigate the relationship between the apical foramen morphology and the length of merged canal at the apex in type II root canal system. Materials and Methods: This study included intact extracted maxillary and mandibular human premolars (n = 20) with fully formed roots without any visible signs of external resorption. The root segments were obtained by removing the crown 1 mm beneath the cementum-enamel junction (CEJ) using a rotary diamond disk. The distance between the file tip and merged point of joining two canals was defined as Lj. The roots were carefully sectioned at 1 mm from the apex by a slow-speed water-cooled diamond saw. All cross sections were examined under the microscope at ${\times}50$ magnification and photographed to estimate the shape of the apical foramen. The longest and the shortest diameter of apical foramen was measured using ImageJ program (1.44p, National Institutes of Health). Correlation coefficient was calculated to identify the link between Lj and the apical foramen shape by Pearson's correlation. Results: The average value of Lj was 3.74 mm. The average of proportion (P), estimated by dividing the longest diameter into the shortest diameter of the apical foramen, was 3.64. This study showed a significant negative correlation between P and Lj (p < 0.05). Conclusions: As Lj gets longer, the apical foramen becomes more ovally shaped. Likewise, as it gets shorter, the apical foramen becomes more flat shaped.

만성적인 산통증상 발현마의 장결석 외과적 치료 및 성분 분석 (Surgical Correction and Componential Analysis of Enterolith in Horse)

  • 양영진;조영재;조길재
    • 한국임상수의학회지
    • /
    • 제31권3호
    • /
    • pp.250-252
    • /
    • 2014
  • 산통 증상을 보인 12세된 웜블러드(거세, 540 kg) 말로부터 임상검사 및 실험실 검사결과 모래 등 이물에 의한 장폐색으로 진단하여 개복술과 장절개술을 실시한 결과 장결석을 확인하여 적출하였다. 적출한 장결석은 약 2.9 kg, 녹갈색, 럭비공 크기($22cm{\times}10cm$)였다. 주사전자현미경(FE-SEM, Hitachi S-4300모델)을 이용하여 원소성분(EDX)을 분석한 결과 400배율에서 C(30.08%), O(39.85%), Mg(3.89%), P(11.15%), Ca(11.16%)가 높게 나타났다. 국내 말에서 크기가 가장 큰 장결석 적출 및 치료가 성공적으로 진행된 최초의 예로서 그 의의가 있다고 볼 수 있다.

Control strategy of the lever-type active multiple tuned mass dampers for structures

  • Li, Chunxiang;Han, Bingkang
    • Wind and Structures
    • /
    • 제10권4호
    • /
    • pp.301-314
    • /
    • 2007
  • The lever-type active multiple tuned mass dampers (LT-AMTMD), consisting of several lever-type active tuned mass dampers (LT-ATMD), is proposed in this paper to attenuate the vibrations of long-span bridges under the excitation directly acting on the structure, rather than through the base. With resorting to the derived analytical-expressions for the dynamic magnification factors of the LT-AMTMD structure system, the performance assessment then is conducted on the LT-AMTMD with the identical stiffness and damping coefficient but unequal mass. Numerical results indicate that the LT-AMTMD with the actuator set at the mass block can provide better effectiveness in reducing the vibrations of long-span bridges compared to the LT-AMTMD with the actuator set at other locations. An appealing feature of the LT-AMTMD with the actuator set at the mass block is that the static stretching of the spring may be freely adjusted in accordance with the practical requirements through changing the location of the support within the viable range while maintaining the same performance (including the same stroke displacement). Likewise, it is shown that the LT-AMTMD with the actuator set at the mass block can further ameliorate the performance of the lever-type multiple tuned mass dampers (LT-MTMD) and has higher effectiveness than a single lever-type active tuned mass damper (LT-ATMD). Therefore, the LT-AMTMD with the actuator set at the mass block may be a better means of suppressing the vibrations of long-span bridges with the consequence of not requiring the large static stretching of the spring and possessing a desirable robustness.

아연분말을 이용한 강재부식 유지보수 효율성 향상 기술 개발 (Development of Technology to Improve Maintenance Efficiency of Steel Corrosion using Zinc Powder)

  • 김동익
    • 한국재난정보학회 논문집
    • /
    • 제16권2호
    • /
    • pp.411-419
    • /
    • 2020
  • 연구목적: 본 연구는 건축물 및 교통 시설물 등에 사용중인 강재류가 시간에 흐름에 따라 부식이 발생됨에 따라 부식된 강재의 성능을 향상시키고 유지보수 효율성을 확보하기 위해 수분 경화형 방식 코팅액을 개발하였고, 그 성능 시험을 통해 최적의 성분 배율을 결정하도록 하였다. 연구방법: 연구를 위하여 다양한 배율의 코팅액에 대해 내식성 평가, 물리적 성질 평가, 저장안전성 평가 등을 시행하여 그 결과를 분석하였다. 연구결과: 분석결과 마그네슘을 추가로 첨가한 액체에서 컷팅 부위에 발청이 거의 없어 방식효과가 우수하였고, 블리스터 발생도 거의 없어 가장 우수한 배율로 분석되었다. 결론: 본 연구를 통해 그 성능이 인정된 수분 경화형 방식 코팅액에 대해 향후 새로운 성분 배율 실험을 통한 기능 향상과 시행 확대를 위한 제도적 개선 노력이 필요하다.

리본 형태의 근관에서 열연화주입법의 근관벽에 대한 적합도에 관한 연구 (A COMPARISON OF THERMOPLASTICIZED INJECIABLE GUTTA-PERCHA TECHNIQUES IN RIBBON-SHAPED CANALS : ADAPTATION TO CANAL WALLS)

  • 황현숙;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.411-420
    • /
    • 2002
  • The aim of this study is to compare the adaptability of thermoplasticized injectable gutta-percha technique to the canal walls in ribbon-shaped canals. Thirty resin models simulated ribbon-shape canals were instrumented to #40 using .06 taper Profile systems. Three groups of each 10 resin models were obturated by the lateral condensation technique(LC) and the two thermoplasticized injectable gutta-percha technique; Ultrafil Endoset+Obtura II(EO) and Ultrafil Firmset(UF), respectively. After resin model were kept at room temperature for 4 days, they were resected horizontally with micro-tome at 1, 2, 3, 4 and 5mm levels from apex. At each levels. image of resected surface were taken using CCD camera under a stereomicroscope at $\times$40 magnification and stored. Ratio of the area of gutta-percha was obtained by calculating area of gutta-percha cone to the total area of canal using digitized image-ana-Iyzing program. The data were collected then analyzed statistically using One-way ANOVA. The results were as follows. 1 At 1mm levels, there was no statistically significant difference in the mean ratio of gutta-percha among the groups. 2. At 2mm level, EO showed the highest mean ratio of gutta-percha (p<0.05) and there was no significant difference between LC and UF. 3. At 3, 4, 5mm levels, EO and UF had significantly greater mean ratio of gutta-percha than LC(p<0.05) and there was no significant difference between EO and UF. In conclusion, the thermoplasticized injectable gutta-percha techniques demonstrated relatively favorable adaptability to canal walls than lateral condensation technique in ribbon-shaped canals except for 1mm level.

미터 소급성을 갖는 원자간력 현미경을 이용한 1차원 격자 피치 측정과 불확도 평가 (Pitch Measurement of One-dimensional Gratings Using a Metrological Atomic Force Microscope and Uncertainty Evaluation)

  • 김종안;김재완;박병천;엄태봉;강주식
    • 한국정밀공학회지
    • /
    • 제22권4호
    • /
    • pp.84-91
    • /
    • 2005
  • We measured the pitch of one-dimensional (ID) grating specimens using a metrological atomic force microscope (M-AFM). The ID grating specimens a.e often used as a magnification standard in nano-metrology, such as scanning probe microscopy (SPM) and scanning electron microscopy (SEM). Thus, we need to certify the pitch of grating specimens fur the meter-traceability in nano-metrology. To this end, an M-AFM was setup at KRISS. The M-AFM consists of a commercial AFM head module, a two-axis flexure hinge type nanoscanner with built-in capacitive sensors, and a two-axis heterodyne interferometer to establish the meter-traceability directly. Two kinds of ID grating specimens, each with the nominal pitch of 288 nm and 700 nm, were measured. The uncertainty in pitch measurement was evaluated according to Guide to the Expression of Uncertainty in Measurement. The pitch was calculated from 9 line scan profiles obtained at different positions with 100 ㎛ scan range. The expanded uncertainties (k = 2) in pitch measurement were 0.10 nm and 0.30 nm for the specimens with the nominal pitch of 288 nm and 700 nm. The measured pitch values were compared with those obtained using an optical diffractometer, and agreed within the range of the expanded uncertainty of pitch measurement. We also discussed the effect of averaging in the measurement of mean pitch using M-AFM and main components of uncertainty.